Solution Type Technical Instruction Sure Solution 1015266.1 : L20/L40/L80 - Troubleshooting the FC connectivity of L-Series libraries in HP environment
PreviouslyPublishedAs 223250 Applies to:Sun StorageTek L180 Tape Library - Version Not Applicable and laterSun StorageTek L20 Tape Library - Version Not Applicable and later Sun StorageTek L40 Tape Library - Version Not Applicable and later Sun StorageTek L80 Tape Library - Version Not Applicable and later Sun StorageTek L700e Tape Library - Version Not Applicable and later All Platforms Checked for relevance on 25-July-2012. GoalThis article troubleshoots the FC connectivity issues of L-Series libraries in a HP environment. FixSteps to Follow
2. If the library is connected to a switch look at the Node List View on the switch if you can see the library. 3. Run ioscan -fn and identify the HP HBA in the example below it is /dev/fcms0:
fc 0 8/4 fcT1 CLAIMED INTERFACE HP Fibre Channel Mass Storage Adapter 4. Run fcmsutil /dev/fcms0 => Node/Port WWName, Topology 5. Ensure schgr driver is loaded: 6. Run ioscan fn and find the device name of the library: Class I H/W Path Driver S/W State H/W Type Description 7. The next command will produce a list of volumes in the library: