Sun Microsystems, Inc.  Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1015240.1
Update Date:2011-08-10
Keywords:

Solution Type  Technical Instruction Sure

Solution  1015240.1 :   VTL - What does the BIOS Erratum 131 message mean during boot up?  


Related Items
  • Sun StorageTek VTL Plus Storage Appliance
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Virtual Tape>SN-TP: VTL
  •  
  • .Old GCS Categories>Sun Microsystems>Storage - Tape>Tape Virtualization
  •  

PreviouslyPublishedAs
223183


Applies to:

Sun StorageTek VTL Plus Storage Appliance - Version: 1.0 - Build 1323 to 2.0 - Build 1656 - Release: 1.0 to 2.0
Information in this document applies to any platform.
.
***Checked for relevance on 10-08-2011*** (dd-mm-yyyy)

Goal

To describe what the BIOS Erratum 131 message means during boot up.

The following message can be seen during boot up on V40Z based VTL's:

"WARNING: BIOS microcode patch for AMD Athlon[TM] 64/Opteron[TM] processor erratum 131 was not detected; updating your system's BIOS to a version containing this microcode patch is HIGHLY recommended or erroneous system operation may occur"

Solution

Message can be safely ignored. 


Description: The user sees the following message:

"WARNING: BIOS microcode patch for AMD Athlon(tm) 64/Opteron(tm) processor erratum 131 was not detected; updating your system's BIOS to a version containing this microcode patch is HIGHLY recommended or erroneous system operation may occur."

The BIOS needs to implement the new workaround for AMD Erratum 169 and should remove the workaround for AMD Erratum 131. As a result, the Erratum 131 message in the Solaris kernel should be removed.

Workaround: The Erratum 131 message can be safely ignored. The errata have been fixed as directed by AMD. The Erratum 131 warning message will be eliminated when the full coordinated errata 131 and 169 are addressed in Solaris 10, Update 4.

Erratum number 131 - 'Systems may deadlock waiting for a Probe Response'.'Under a highly specific and detailed set of internal timing conditions, the Northbridge System Request Queue may stall, and cause a watchdog timer timeout and system will deadlock'. It also mentions the system will hang or machine check in the erratum 169 message detail.