Solution Type  Technical Instruction Sure

Solution  1013975.1 :   SL500 - Do the Reserved Slots Count Against the Total Storage Capacity?  


Related Items
  • Sun StorageTek SL500 Modular Library System
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL500 Library
  •  

PreviouslyPublishedAs
220113


Applies to:

Sun StorageTek SL500 Modular Library System - Version Not Applicable and later
All Platforms
Checked for relevance on 24-May-2012.

Goal

This article addresses if the reserved slots count against the total storage capacity.

Source:
SL500 Modular Library System Installation Manual.
Found under heading of Physical Configurations in Chapter 1, Planning the Installation.

Fix

Yes, the reserved slots count as part of the total storage capacity.

For example, if the library is licensed for 100 slots and 2 of the slots are reserved, there would be 98 slots available for data cartridges.
However, the SCSI element mapping starts at the first NON-RESERVED slot, so if the library has 2 reserved slots, the first SCSI element will be in the third row of column 1.