![]() | Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Technical Instruction Sure Solution 1013602.1 : SL500 - How Long Does It Take to Initialize and Audit Library
PreviouslyPublishedAs 219155 Applies to:Sun StorageTek SL500 Modular Library System - Version Not Applicable and laterAll Platforms Checked for relevance on 24-May-2012. GoalThis document describes SL500 - How Long Does It Take to Initialize and Audit Library. FixSteps to Follow 100 Rnd Cell to Cell Time Power Cycle to Ready ==================================================== MIXED media version: Power Cycle to Ready 100 Rnd Cell to Cell Time scan audit enabled scan audit disabled The AUDIT time depends on the configuration. Here's information on the largest and smallest configurations: Init time: Measured from power up (switch on) to when robot moves to first cell to start audit. Audit time: Measured from robot positioned in front of first cell to audit completion where the robot is parked in front of the last drive and the library reports "ready". 40u library Total number of CAP cells 45 Init time: 3 min 30 sec Audit time: 29 min 30 sec Total time: 33 min
8u library Total number of CAP cells 5 Init time: 2 min Audit time: 6 min 30 sec Total time: 8 min 30 sec
Attachments This solution has no attachment |
||||||||||||
|