Asset ID: |
1-71-1012360.1 |
Update Date: | 2012-09-14 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1012360.1
:
How to determine which systems have ILOM/ALOM4v/ALOM/LOM/ELOM/SP/XSCF or RSC ?
Related Items |
- Sun Netra T5440 Server
- Sun Blade X6450 Server Module
- Sun Fire X2200 M2 Server
- Sun Fire T1000 Server
- Sun Fire V215 Server
- Sun Fire V245 Server
- Sun Blade X6240 Server Module
- Sun Fire V240 Server
- Sun Fire V445 Server
- Sun Fire X4200 Server
- Sun SPARC Enterprise T5440 Server
- Sun Fire T2000 Server
- Sun Blade T6300 Server Module
- Sun Blade X6220 Server Module
- Sun Fire V480 Server
- Sun Blade X6440 Server Module
- Sun Blade X6270 Server Module
- Sun Fire V250 Server
- Sun Fire X4600 M2 Server
- Sun Fire V440 Server
- Sun Fire V125 Server
- Sun SPARC Enterprise T5120 Server
- Sun Netra 440 Server
- Sun Fire V490 Server
- Sun Fire X4200 M2 Server
- Sun Fire V880z Visualization Server
- Sun Netra T2000 Server
- Sun Server X3-2
- Sun Fire V210 Server
- Sun SPARC Enterprise T5220 Server
- Sun Fire V880 Server
- Sun Server X2-8
- Sun Server X3-2L
- Sun Fire V1280 Server
- Sun Fire X4100 M2 Server
- Sun Blade X6275 Server Module
- Sun Fire E2900 Server
- Sun Fire X2100 M2 Server
- Sun SPARC Enterprise T5240 Server
- Sun Blade X6250 Server Module
- Sun Fire X4270 M2 Server
- Sun Blade X3-2B
- Sun Fire V890 Server
- Sun Blade X6420 Server Module
- Sun Netra T5220 Server
- Sun Fire X4600 Server
- Sun Fire X4100 Server
- Sun Blade T6320 Server Module
- Sun Blade T6340 Server Module
- Sun SPARC Enterprise T5140 Server
- Sun Fire X4500 Server
- Sun SPARC Enterprise T2000 Server
- Sun Fire X4170 M2 Server
- Sun Server X2-4
|
Related Categories |
- PLA-Support>Sun Systems>SPARC>Usx/Blade/Netra>SN-SPARC: USx
- .Old GCS Categories>Sun Microsystems>Servers>Blade Servers
- .Old GCS Categories>Sun Microsystems>Servers>NEBS-Certified Servers
- .Old GCS Categories>Sun Microsystems>Servers>Midrange Servers
- .Old GCS Categories>Sun Microsystems>Servers>Entry-Level Servers
- .Old GCS Categories>Sun Microsystems>Specialized Systems>Grid Systems
- .Old GCS Categories>Sun Microsystems>Servers>x64 Servers
- .Old GCS Categories>Sun Microsystems>Servers>CMT Servers
|
PreviouslyPublishedAs
217050
Applies to:
Sun Fire V480 Server - Version Not Applicable and later
Sun Netra T5440 Server - Version Not Applicable and later
Sun Blade X6440 Server Module - Version Not Applicable and later
Sun Blade X6450 Server Module - Version Not Applicable and later
Sun Fire V445 Server - Version Not Applicable and later
All Platforms
Goal
This document describes which systems have either:
Lights Out Manager (LOM)
Advanced LOM (ALOM)
Advanced LOM for Solaris[TM] Sun4v kernel architecture (ALOM4v)
Integrated Lights Out Manager (ILOM)
Embedded Lights Out Manager (ELOM)
Sun[TM] Remote System Console (RSC) for system management
Embedded Service Processor (SP)
eXtended System Controller Facility (XSCF)
Fix
Please refer to the following resources:
LOM
Sun Netra[TM] X1
Sun Netra[TM] T1400/1405
Sun Netra[TM] T1 AC200
Sun Netra[TM] T1 DC200
Sun Fire[TM] V100
Sun Fire[TM] V120
Sun Netra[TM] 20
Sun Netra[TM] 1280 **
Sun Netra[TM] 1290 **
Sun Fire[TM] V1280 **
Sun Fire[TM] E2900 **
** The LOM for the Sun Fire[TM]V1280/E2900 is delivered as part of the ScApp.
See the Hardware/PROM: 5.20.16: Sun Fire E6900/E4900/E2900/6800/4800/4810/3800/V1280 Netra 1280 and Netra 1290 Systems FW Update
ALOM
Sun Fire[TM] V125
Sun Fire[TM] V210
Sun Fire[TM] V215
Sun Fire[TM] V240
Sun Fire[TM] V245
Sun Fire[TM] V250
Sun Fire[TM] V440
Sun Fire[TM] V445
ALOM4v
Sun Fire[TM] T1000
Sun Fire[TM] T2000
Sun SPARC[TM] Enterprise T1000
Sun SPARC[TM] Enterprise T2000
Sun Netra[TM] T2000
Sun Blade[TM] T6300
ILOM
Sun Fire[TM] X4100
Sun Fire[TM] X4170 M2
Sun Fire[TM] X4170 M3 (Sun Server X3-2)
Sun Fire[TM] X4200
Sun Fire[TM] X4270 M2
Sun Fire[TM] X4270 M3 (Sun Server X3-2L)
Sun Fire[TM] X4470 M2(Sun Server X2-4)
Sun Fire[TM] X4500
Sun Fire[TM] X4600
Sun Fire[TM] X4100 M2
Sun Fire[TM] X4200 M2
Sun Fire[TM] X4600 M2
Sun Fire[TM] X4800 M2 (Sun Server X2-8)
Sun Blade[TM] 6000 CMM
Sun Blade[TM] 8000 CMM
Sun Netra[TM] X4200 M2
Sun Blade[TM] X6220
Sun Blade[TM] X6240 Server Module
Sun Blade[TM] X6220 Server Module
Sun Blade[TM] X6275 Server Module
Sun Blade[TM] X6270 Server Module
Sun Blade[TM] X6270 M3 (Sun Blade X3-2B) Server Module
Sun Blade[TM] X6440 Server Module
Sun SPARC Enterprise[TM] T5140 - ILOM 2.x or 3.x + ALOM4v emulation
Sun SPARC Enterprise[TM] T5240 - ILOM 2.x or 3.x + ALOM4v emulation
Sun SPARC Enterprise[TM] T5440 - ILOM 2.x or 3.x + ALOM4v emulation
Sun SPARC[TM] Enterprise T5120
Sun SPARC[TM] Enterprise T5220
Sun Blade[TM] T6340 Server Module - ILOM 2.x or 3.x + ALOM4v emulation
Sun Blade[TM] T6320
ELOM
Sun Fire[TM] X2100 M2
Sun Fire[TM] X2200 M2
Sun Blade X6250 Server Module - ELOM (no longer updated), ILOM 2.x or 3.x
Sun Blade X6450 Server Module - ELOM (no longer updated) ILOM 2.x or 3.x
RSC
Sun Fire[TM] V890
Sun Fire[TM] V490
Sun Fire[TM] V880
Sun Fire[TM] V480
Sun Fire[TM] 280R
Sun Enterprise[TM] 250
SP
Sun Fire[TM] V20z
Sun Fire[TM] V40z
XSCF
Sun SPARC Enterprise[TM] M3000
Sun SPARC Enterprise[TM] M4000
Sun SPARC Enterprise[TM] M5000
Sun SPARC Enterprise[TM] M8000
Sun SPARC Enterprise[TM] M9000-32
Sun SPARC Enterprise[TM] M9000-64
Reference Manuals
All available from http://www.oracle.com/technetwork/indexes/documentation/index.html
A good place to start is Managing Sun Systems - Sun Integrated Lights Out Manager
ALOM HowTos:
<Document: 1004884.1> How to configure the "NET MGT" port (ALOM Advanced Lights Out Manager Ethernet
<Document: 1009021.1> How to configure the ALOM Notification Variables
Advanced Lights Out Manager (ALOM) Download Instructions:
- Login to MOS and go to the Patches & Updates tab.
- In the patch search field click on Product or Family
- In the product field put in 'Advanced Lights Out Manager' and click the search button.
- The next page will provide a patch name 10263984
- Click the patch number 10263984 and the page will show a button for Download
- Click 'Download' and obtain the file shown: p10263984_160_Generic.zip
- Unzip the file, it will provide the following firmware:
* ALOM_1.6.10_fw_hw0.tar.gz - ALOM 1.6.10 Firmware for Sun Fire V125, V210, V240, V250, V440, and Netra 210, 240 and 440
* ALOM_1.6.10_fw_hw8.tar.gz - ALOM 1.6.10 Firmware for Sun Fire V215, V245 and V445
RSC
RSC Software Download and Installation Instructions
RSC Software Download (steps to download the latest RSC software):
1. Login to MOS and select "Patches and Updates Tab"
2. In "Patch Search" on the Top right panel, Click on "Product or Family (Advanced Search)"
3. In the "Product Is" pull-down select "Sun remote System Control"??
4. In the next pull down "Release is" select the RSC version (2.2.2 or 2.2.3).
5. Select OS and click "Search" (will get a list with RSC releases & patches)
6. Select the desired RSC Release (packages) or patch
7. Click Download on the Right
The packages for Solaris 8 and 9 (and later) are both in the zip file. There are two options of the zip file, 32bit, and 64bit, but they both have the same checksums, so there are no differences: p10264452_223_SOLARIS64.zip (p10264451_223_SOLARIS.zip)
Sun Remote System Control (RSC) for Sun Enterprise 250, Sun Fire 280R, Sun Fire V480, Sun Fire V490, Sun Fire V880, and Sun Fire V890 Servers
Sun Remote System Control (RSC) Installation Guide
Sun Remote System Control (RSC) Users Guide
RSC Engineering page
SP
Sun Fire V20z and Sun Fire V40z Servers--Server Management Guide
XSCF
Sun SPARC[TM] Enterprise M3000, M4000, M5000, M8000, M9000 XSCF Control Package (XCP) Firmware Image Software Version Matrix Information (Doc ID 1002631.1)
Sun SPARC(R) Enterprise M3000/M4000/M5000/M8000/M9000 (OPL): XCP FAQs (Doc ID 1393702.1)
Documentation:
SPARC Enterprise M3000/M4000/M5000/M8000/M9000 Servers XSCF User’s Guide
SPARC Enterprise M3000/M4000/M5000/M8000/M9000 Servers Administration Guide
RSC, LOM, ILOM, ALOM, ELOM, NET MGT, V890, V490, V880, V440, V250, V124, V215, V245, V445V240, V210, V1280, E2900, V120, V100, Netra T1 DC200, Netra T1 AC200, Netra X1, V480, 280R, Enterprise 250, sys_eventlevel, mgt_mailalert, T2000, T1000, X4100, X4200, X4500, X4600, X2100 M2, X2200 M2, T6300, T6320, X6220, X6250, X6450
Previously Published As
81146
Change History
Date: 2009-12-16
User Name: 79977
Action: Currency check
Comment: Updated/checked - Alan Nicolas, John Adams
Date: 2007-10-30
User Name: 97961
Action: Approved
Comment: Publishing. No further edits required.
Version: 30
Date: 2007-10-30
User Name: 97961
Action: Accept
Comment:
Version: 0
Date: 2007-10-30
User Name: 114416
Action: Approved
Comment: good doc ok to publish
Version: 0
References
<NOTE:1009021.1> - How To Configure the ALOM Notification Variables
<NOTE:1004884.1> - How To Configure the ALOM "NET MGT" Port for Sun Fire V125, V210, V215, V240, V245, V250, V440, V445 and Netra 210, 240, 440 Servers
Attachments
This solution has no attachment