![]() | Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Technical Instruction Sure Solution 1011553.1 : SVA - ICKDSF and Oracle Virtual Disk Storage Systems
PreviouslyPublishedAs 215855 Applies to:Sun StorageTek V2X SVA Disk System - Version Not Applicable to Not Applicable [Release N/A]All Platforms Reviewed for currency 05/25/11 GoalICKDSF and Oracle Virtual Disk Storage Systems. Various occurrences of data checks and equipment checks require the usage of ICKDSF to release the bad tracks. Usually, the EQC or DCK is accompanied by FSC40C0 or FSC3C90. FixGenerally, these tracks will be cleaned up by freespace collection after the dataset containing the track has been deleted, if DDSR is active. Only one 'golden' set of ICKDSF parameters will work to release the defective track images. An example of a job to release one track is included below. Run the following job, where XXXXXX is the volser and X'CCCC',X'HHHH is the track. //JOBCARD JOB Host System IBM Software: Only Release 16 of ICKDSF is supported by IBM. APAR PQ02288 must be applied to support SVA devices. Refer to IBM Manual ICKDSF GC35-0033-23. Specifications in this manual referring to the RAMAC Array Family applies to the SVA.
vu 12/20/94 created Previously Published As Attachments This solution has no attachment |
||||||||||||
|