Sun Microsystems, Inc.  Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1011180.1
Update Date:2012-05-10
Keywords:

Solution Type  Technical Instruction Sure

Solution  1011180.1 :   How to determine the version of Sun Storage Common Array Manager (CAM) ?  


Related Items
  • Sun Storage 6580 Array
  •  
  • Sun Storage 6180 Array
  •  
  • Sun Storage 2510 Array
  •  
  • Sun Storage 2540 Array
  •  
  • Sun Storage 2540-M2 Array
  •  
  • Sun Storage Common Array Manager (CAM)
  •  
  • Sun Storage 6780 Array
  •  
  • Sun Storage 6140 Array
  •  
  • Sun Storage 2530 Array
  •  
  • Sun Storage 2530-M2 Array
  •  
  • Sun Storage 6540 Array
  •  
  • Sun Storage 6130 Array
  •  
Related Categories
  • PLA-Support>Sun Systems>DISK>Disk Device Software>SN-DK: CAM
  •  
  • .Old GCS Categories>Sun Microsystems>Storage - Disk>Modular Disk - 6xxx Arrays
  •  

PreviouslyPublishedAs
215369


Applies to:

Sun Storage 2540 Array - Version Not Applicable and later
Sun Storage 2540-M2 Array - Version Not Applicable and later
Sun Storage Common Array Manager (CAM) - Version 6.0 to 6.8 [Release 6.0]
Sun Storage 6130 Array - Version Not Applicable and later
Sun Storage 6580 Array - Version Not Applicable and later
All Platforms

Goal

The intend of this document is to give a simple procedure to determine the version of Sun Storage Common Array Manager (CAM) installed on the management host.

Fix

Method using the Command Line (CLI)

Note: This requires the use of the local sscs binary located under:

Solaris: /opt/SUNWstkcam/bin/
Linux: /opt/sun/cam/bin/
Windows: C:\Program Files\Sun\Common Array Manager\bin

 

  1. Execute `sscs list mgmt-sw`.

    Example:

    bash-3.00# sscs list mgmt-sw
    Application Name:   "Sun Storage Common Array Manager"
    User:               local
    Current Logins:     1
    Sessions:           none
    Server:             localhost
    Server OS:          SunOS
    Server OS Version:  5.10
    Product Version:    6.8.0.20
    Build Date:         June 4, 2011
    Install Info:       6.8.0.20
    Critical Alarms:    0
    Down Alarms:        0
    Major Alarms:       0
    Minor Alarms:       0
    bash-3.00#

Method using the Graphical User Interface (GUI)

  1. Log into CAM (https://<CAM server IP>:6789).
  2. Click on "Sun Storage Common Array Manager".
  3. Click on "VERSION" on the top left in CAM.

Attachments
This solution has no attachment
  Copyright © 2012 Sun Microsystems, Inc.  All rights reserved.