Sun Microsystems, Inc.  Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1010687.1
Update Date:2012-07-30
Keywords:

Solution Type  Technical Instruction Sure

Solution  1010687.1 :   VLAN support on Sun Fire[TM] V20z/V40z and Sun Java[TM] W1100z/W2100z Broadcom Gigabit Ethernet Ports  


Related Items
  • Sun Fire V20z Server
  •  
  • Sun Fire V240 Server
  •  
  • Sun Java Workstation W1100z
  •  
  • Sun Fire V210 Server
  •  
  • Sun Blade 2500 Workstation
  •  
  • Sun Fire V40z Server
  •  
  • Sun Blade 1500 Workstation
  •  
  • Sun Java Workstation W2100z
  •  
Related Categories
  • PLA-Support>Sun Systems>x64>Server>SN-x64: SERVER 64bit
  •  

PreviouslyPublishedAs
214758


Applies to:

Sun Java Workstation W2100z - Version Not Applicable and later
Sun Fire V20z Server - Version Not Applicable and later
Sun Fire V210 Server - Version Not Applicable and later
Sun Fire V240 Server - Version Not Applicable and later
Sun Fire V40z Server - Version Not Applicable and later
All Platforms
***Checked for relevance on 08-Jun-2012***

Goal

 Can you use VLAN tagging over the two 10x100x1000 Ethernet ports on-board of the V20z and other Sun[TM] Workstations or Servers?

Fix

Yes. The v20z has 2 BGE interfaces on-board.
VLAN tagging (IEEE 802.1Q) is implemented in BGE and GLD starting with a  Solaris[TM] 9 Operating System Feature Patch.

It is supported by the following minimum releases:

- Feature Patch Solaris[TM] x86:
116485-03 SunOS 5.9_x86: Broadcom Gigabit Ethernet (BGE) Driver
112234-11 SunOS 5.9_x86: Kernel Patch (required as it delivers the gld changes)

- Feature Patch Solaris[TM] SPARC:
112233-11 SunOS 5.9: Kernel Patch (delivers both BGE and GLD)

- Solaris has BGE VLAN tagging support built in starting with Solaris[TM] 9 4/04 (Solaris 9 Update 6)

This is applicable for the following Sun Workstations or Servers, also:
Sun Fire[tm] V210, Sun Fire[TM] V240, Sun Blade[TM] 1500, Sun Blade[TM] 2500, Sun Fire[TM] V40z, Sun Java[TM] Workstation W1100z, Sun Java[TM] Workstation W2100z.

For more information on the BGE interface, see:
Technical Instruction <Document: 1001843.1>  BGE Gigabit Ethernet - First Checks

For more information on products supporting VLAN tagging, see:
Technical Instruction <Document: 1005717.1>  Do Sun ethernet NICs and switch products have VLAN support?

 