Goal
This document will show you how to blacklist components such as CPU's, system boards, memory and even half of the centerplane for the Sun Enterprise[TM] 10000.
Fix
Log into the SSP and edit the file:
- vi /var/opt/SUNWssp/etc/<plaform-name>/blacklist
and add the following parameters for the corresponding component/action:
Component/Action |
Parameter |
Example |
CPU |
proc <system-board>.<proc-number> |
proc 1.2 |
System board |
sysbd <system-bd number> |
sysbd 10 |
sbus card |
scard <sb>.<ioctl>.<slot> |
scard 4.1.0 |
Disable memory |
mem <sb> |
mem 0 |
Disable half of the centerplane |
cplane <half-centerplane> |
cplane 1 |
Disable a port controller |
pc <sb>.<pc> |
pc 0.1 |
Disable an xdb |
xdb <sb>.<xdb> |
xdb 0.2 |
Disable a cic |
cic <sb>.<cic> |
cic 0.1 |
Note: for the blacklist entry to take effect, the domain must be restarted via a bringup command.
Product
Sun Enterprise 10000 Server
System Service Processor 3.5
System Service Processor 3.3
System Service Processor 3.4 (English)
System Service Processor 3.1
Internal section
Keywords: blacklist, e10k
Previously Published As 80682
Product_uuid
29ddef46-0a18-11d6-92de-ae47474f0f6c|Sun Enterprise 10000 Server
837821c8-9ae0-4e3c-8ee2-5f80eed3f977|System Service Processor 3.5
b2448136-2bd5-11d6-85ce-9bcbc88fff45|System Service Processor 3.3
af987870-2bd5-11d6-9cc8-c799d5cf7ed3|System Service Processor 3.4 (English)
a3deebd6-2bd5-11d6-9d5b-db171ac7152c|System Service Processor 3.1
Attachments
This solution has no attachment