Sun Microsystems, Inc.  Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1009344.1
Update Date:2012-07-30
Keywords:

Solution Type  Technical Instruction Sure

Solution  1009344.1 :   Sun StorEdge[TM] 9900 series: Explain Striping Group size for RAID 5 (7D+1P), RAID 1 (4D+4D) and RAID 6 (6D+2P) with HDD model 146GB or larger  


Related Items
  • Sun Storage 9990 System
  •  
  • Sun Storage 9970 System
  •  
  • Sun Storage 9985 System
  •  
  • Sun Storage 9980 System
  •  
Related Categories
  • PLA-Support>Sun Systems>DISK>HighEnd Arrays>SN-DK: HDS_99xx
  •  
  • .Old GCS Categories>Sun Microsystems>Storage - Disk>Datacenter Disk
  •  

PreviouslyPublishedAs
212928


Applies to:

Sun Storage 9970 System - Version Not Applicable to Not Applicable [Release N/A]
Sun Storage 9980 System - Version Not Applicable to Not Applicable [Release N/A]
Sun Storage 9985 System - Version Not Applicable to Not Applicable [Release N/A]
Sun Storage 9990 System - Version Not Applicable to Not Applicable [Release N/A]
All Platforms

Goal

 Sun StorEdge[TM] 99x0 series: Explain Striping Group size for RAID 5 (7D+1P), RAID 1 (4D+4D) and RAID 6 (6D+2P) with HDD model 146GB or larger.

With the introduction of 146GB HDD and larger, for Sun StorEdge[TM] 9970, 9980,9985 and 9990, HDS/Hitachi has implemented Striping Groups to overcome limitations in representing very large Parity Groups in cache.

The maximum capacity of the striping groups must be considered, if using OPEN-V or LUSE/CVS.

Fix

A Striping Group is a virtual Parity Group within the real Parity Group.

During configuration, if the platform has any of the following configurations, a "Striping Group Configuration window" will be displayed:

  • HDD models of 146GB capacity or larger
   Plus any of the following:
  • RAID 5 (7D+1P)
  • RAID 6 (6D+2P)
  • RAID 1 (4D+4D)

In any other conditions, the Striping Group is equal to the Parity Group, so a "Striping Group Configuration window" will NOT be displayed.

Sun StorEdge[TM] 9970 and Sun StorEdge[TM] 9980

Please consult following sections of the Maintenance Manual:

  • INST01-290 Drive Expansion Sequence RAID5 (7D+1P)
  • INST05-180 Striping Group Configuration window
  • OPEN03-280 OPEN-V Setting
  • OPEN03-290 LUSE definition

If selecting OPEN-V or LUSE/CVS, consider the size, based on the above references. The Striping Groups have different capacities, and combined, they reflect the capacity of the Parity Group.

For example:

  • RAID5 (7D+1P) Striping Group (1) = 0.75TB (decimal) = 737256 MB
  • RAID5 (7D+1P) Striping Group (2) = 0.27TB (decimal) = 222440 MB
  • RAID5 (7D+1P) Parity Group = 1.02TB (decimal) = 959696 MB

Sun StorEdge[TM] 9990

Please consult following sections of the Maintenance Manual:

  • INST01-530 Drive Expansion Sequence RAID5 (7D+1P/6D+2P)
  • INST01-590 Drive Expansion Sequence RAID5 (7D+1P/6D+2P)
  • INST05-200 Striping Group Configuration window
  • OPEN03-320 OPEN-V Setting

Sun StorEdge[TM] 9985

Please consult following sections of the Maintenance Manual:

  • INST05-210 Striping Group Configuration window
  • OPEN03-320 OPEN-V Setting

Sun StorEdge[TM] 9990V

Please consult following sections of the Maintenance Manual:

  • INST01-510 Drive Expansion Sequence RAID5 (7D+1P/6D+2P)
  • INST05-240 Striping Group Configuration window
  • OPEN03-310 OPEN-V Setting

Sun StorEdge[TM] 9985V

Please consult following sections of the Maintenance Manual:

  • INST01-320 Drive Expansion Sequence RAID5 (7D+1P/6D+2P)
  • INST05-230 Striping Group Configuration window
  • OPEN03-320 OPEN-V Setting



Product
Sun StorageTek 9980 System
Sun StorageTek 9970 System
Sun StorageTek 9900V Series Array
Sun StorageTek 9990 System
Sun StorageTek 9985 System
300 GB 10Krpm Hard Disk Drive for Sun StorageTek 9990
Sun StorageTek 9960 System
Sun StorageTek 9910

Internal Comments
The following is strictly for the use of Sun employees:

Additional see HDS Solution ID HDS24973 "Striping Group Configuration (9900V)"


se9979, se9980, se9990, se9985, striping group, parity group, open-v, luse, 146gb, 300gb
Previously Published As
82828


Attachments
This solution has no attachment
  Copyright © 2012 Sun Microsystems, Inc.  All rights reserved.
 Feedback