Solution Type  Technical Instruction Sure

Solution  1009194.1 :   Sun Fire[TM] 3800, v1280, E2900, 4800, 4810, E4900, 6800 and E6900 and Netra 1280, 1290: Can't boot from cdrom  


Related Items
  • Sun Fire E6900 Server
  •  
  • Sun Fire 3800 Server
  •  
  • Sun Fire 6800 Server
  •  
  • Sun Fire E4900 Server
  •  
  • Sun Netra 1280 Server
  •  
  • Sun Fire 4800 Server
  •  
  • Sun Fire V1280 Server
  •  
  • Sun Fire E2900 Server
  •  
  • Sun Fire 4810 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>SPARC>Enterprise>SN-SPARC: Exx00
  •  
  • .Old GCS Categories>Sun Microsystems>Servers>Entry-Level Servers
  •  
  • .Old GCS Categories>Sun Microsystems>Servers>Midrange Servers
  •  
  • .Old GCS Categories>Sun Microsystems>Servers>Midrange V and Netra Servers
  •  

PreviouslyPublishedAs
212726


Description
This article is to be used to aid in booting a cd rom from a Sun Fire[TM] server.

When booting from cdrom from a Sun Fire[TM] server, you receive the message:
ok> boot cdrom -s
ERROR: Can't open boot-device


Steps to Follow
The common resolution to this problem points to an incorrect devalias entry for the cdrom.
This is very common especially for configurations with the D240 with split back planes. It is therefore a good idea not to trust the default entries and verify/correct the cdrom entry in the OBP.

Procedure:

1. Issue the probe-scsi-all and sift through the outputs until you see the removable read-only device.
In our example the device path from an E6900 is at:
/ssm@0,0/pci@1e,700000/pci@1/scsi@2, target 6

{4} banner
Sun Fire E6900
OpenFirmware version 5.17.0 (03/05/04 11:27)
Copyright 2001-2004 Sun Microsystems, Inc.  All rights reserved.
Use is subject to license terms.
SmartFirmware, Copyright (C) 1996-2001.  All rights reserved.
32768 MB memory installed, Serial #50823586.
Ethernet address 0:3:ba:7:81:a2, Host ID: 830781a2.

{4} ok probe-scsi-all

/ssm@0,0/pci@1f,700000/SUNW,qlc@2,1
/ssm@0,0/pci@1f,700000/SUNW,qlc@2
*************************  Fabric Attached Devices  ************************
Adapter portId - 10000
   Device PortId 11055   DeviceId 1     WWPN 5005076300617dec
   Lun   0    TAPE  IBM     ULTRIUM-TD2     38D0
   Device PortId 11155   DeviceId 2     WWPN 500507630061779a
   Lun   0    TAPE  IBM     ULTRIUM-TD2     38D0

/ssm@0,0/pci@1e,700000/pci@1/scsi@2,1

/ssm@0,0/pci@1e,700000/pci@1/scsi@2
Target 0
  Unit 0   Disk     HITACHI DK32EJ72NSUN72G PQ08
Target 3
  Unit 0   Processor     Sun     D240            1.09
Target 6
  Unit 0   Removable Read Only device    TOSHIBA DVD-ROM SD-M14011009

/ssm@0,0/pci@1b,700000/SUNW,qlc@2,1

------------------ end of output --------------------
2.  Set the alias for the removable read only device using nvalias and append disk@6,0:f.
Save the entry using the nvstore command.
{4} ok nvunalias cdrom
{4} ok nvalias cdrom /ssm@0,0/pci@1e,700000/pci@1/scsi@2/disk@6,0:f
3.  Reissue the command to boot the domain
{4} ok boot cdrom -s 
See <Document: 1006156.1> "ERROR: Can't open boot device" booting CDROM or disk with Sun[TM] Dual FastEthernet / Dual SCSI PCI Card for related info.

Product
Sun Fire E6900 Server
Sun Fire 6800 Server
Sun Fire 3800 Server
Sun Fire 4800 Server
Sun Fire 4810 Server
Sun Fire E4900 Server
Sun Fire V1280 Server
Netra 1280 Server
Netra 1290 Server
Sun Fire E2900 Server


Attachments
This solution has no attachment
  Copyright © 2012 Sun Microsystems, Inc.  All rights reserved.
 Feedback