Solution Type  Technical Instruction Sure

Solution  1008806.1 :   Sun Fire [TM] 280R: PCI slot 4 is 64 bits wide  


Related Items
  • Sun Fire 280R Server
  •  
Related Categories
  • PLA-Support>Sun Systems>SPARC>Workgroup Servers>SN-SPARC: SF-Vx80
  •  
  • .Old GCS Categories>Sun Microsystems>Servers>Entry-Level Servers
  •  

PreviouslyPublishedAs
212093


Applies to:

Sun Fire 280R Server
All Platforms

Goal

Correctly provide Slot Speed.

Solution

The PCI slot 4 on the Sun Fire [TM] 280R server is 64 bits wide and can accommodate 32 or 64 bit PCI cards. Information about slot 4 is incorrect in the Sun Fire 280R Server Owner's Guide.

Detail

The Sun Fire 280R Server Owner's Guide incorrectly states that PCI slot 4 is 32 bits wide and that it can accommodate only 32 bit PCI cards. The correct information is that PCI slot 4 is 64 bits wide, and it can accommodate both 32 bit and 64 bit PCI cards.

The incorrect information is found in Chapter 4, Hardware and Software Configuration, in the "About Peripheral Component Interconnect (PCI) Buses" section. The table entry for row "PCI 4" and column "Slot Width (bits) / Card Type (bits)" is incorrect. The table entry is "32 / 32", but it should be "64 / 32 or 64".


See:
<SunBug 4450900>