Solution Type Technical Instruction Sure Solution 1008519.1 : SVA/VSM - Define Functional Devices
PreviouslyPublishedAs 211645
Applies to:Sun StorageTek V2X SVA Disk System - Version: Not Applicable to Not Applicable - Release: N/A to N/ASun StorageTek VSM System - Version: 4 to 5C [Release: 4.0 to 5.0] All Platforms GoalAdditional devices cannot be defined on the SVA/VSM. If the IXFP/SVAA software is being used to define volumes, then various error messages including SIB1168E, SIB1132E, and/or SIB1157E may be detected. If the operator panel is being used to define volumes, then FSC 3E9A may be noted.SolutionEXPLANATION: The subsystem has reached the maximum number of cylinders for all functional devices or the maximum number of functional devices.Either of the following limits is a subsystem restriction: * The maximum number of functional devices (excluding 3390-9) is 1024. * The maximum number of total cylinders for all functional devices is product This restriction is due to the total maximum number of cylinders for all devices defined on the subsystem. SOLUTION: Define the functional device types in appropriate combinations without exceeding the limits. The device type sets the number of cylinders for each functional device: * 3390-1 1113 * 3390-2 2226 * 3390-3 3339 * 3390-9 10017 * 3380-J 885 * 3380-KE 1770 * 3380-K 2655 K.W. - 10/06/00 - CREATED. Product Previously Published As 91089 Attachments This solution has no attachment |
||||||||||||
|