![]() | Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Technical Instruction Sure Solution 1007005.1 : How to activate a RAID volume on T1000/T2000, V215/V245/V445, T5120/T5220, T5140/T5240/T5440 Servers
PreviouslyPublishedAs 209680
Applies to:Sun SPARC Enterprise T5240 Server - Version: Not Applicable to Not Applicable - Release: N/A to N/ASun SPARC Enterprise T5440 Server - Version: Not Applicable to Not Applicable [Release: N/A to N/A] Sun Fire T1000 Server - Version: Not Applicable and later [Release: N/A and later] Sun SPARC Enterprise T1000 Server - Version: Not Applicable to Not Applicable [Release: N/A to N/A] Sun SPARC Enterprise T2000 Server - Version: Not Applicable to Not Applicable [Release: N/A to N/A] All Platforms GoalThis document provides a reference to the procedure for re-activating an existing RAID volume after raid controller replacement, on Sun Fire T1000/T2000, V215/V245/V445, SPARC Enterprise T5120/T5220, T5140/T5240/T5440 Servers.SolutionDescriptionThis document provides a reference to the procedure for re-activating an existing RAID volume, on Sun Fire T1000/T2000, V215/V245/V445, SRARC Enterprise T5120/T5220, T5140/T5240 and T5440 Servers. If you have an existing RAID volume and have to replace the raid controller on one of these servers, you'll need to run some OBP commands in order to see the volume with the new board. The outlined procedure includes generic instructions, as well as platform specific instructions. Steps to Follow When the RAID controller for internal disks has been replaced, customers may need to re-activate the RAID volume by using OBP commands. For T2000 systems, if using CPU/mem board part number 501-6843, the controller is a plug-in PCI-X card, part number 370-7696. For all other instances on the T2000, T1000, V215/V245/V445, T5120/T5220, T5140/T5240 and T5440, the controller is on the system board (motherboard). Generic instructions for T1000, T2000, V215/V245/V445, T5x20 and T5x40: Product Sun Fire T2000 Server Sun Fire T1000 Server Sun Fire V245 Server Sun Fire V215 Server Sun Fire V445 Server SPARC Enterprise T5120 Server SPARC Enterprise T5220 Server SPARC Enterprise T5140 Server SPARC Enterprise T5140 Server SPARC Enterprise T5440 Server @ Internal Comments For more details refer to the following docs: 88104 Unable to see a pre-existing RAID volume on Sun Fire[TM] T1000/T2000 87435 RAID on the Sun Fire [TM] V215/245 Servers T1000, T2000, V215, V245, LSI, 1064, OBP, activate, RAID, IM, IS Previously Published As 87749 Change History Date: 2010-08-12 User name: Dencho Kojucharov Action: reviewed/updated Comments: Currency check, audited by Entry-Level SPARC Content Lead Date: 2007-07-24 User Name: 97961 Action: Approved Comment: Publishing. No further edits required. Version: 9 Date: 2007-07-24 User Name: 97961 Action: Accept Comment: Version: 0 Date: 2007-07-24 User Name: 106061 Action: Approved Comment: This document is updated to show that the procedure for re-activating an existing RAID volume is identical for Sun Fire T1000/T2000 and Sun Fire V215/V245 Servers. The documet title, Description and Internal sections are modified accordingly as well. Submitting for final review and publishing. Regards, Version: 0 Date: 2007-07-23 User Name: 88029 Product_uuid 41b7bc41-2581-11da-99bc-080020a9ed93|Sun Fire T2000 Server dd2799dd-e6e5-11da-ac3d-080020a9ed93|Sun Fire V245 Server b8827f5b-e6e5-11da-ac3d-080020a9ed93|Sun Fire V215 Server Attachments This solution has no attachment |
||||||||||||
|