Solution Type  Technical Instruction Sure

Solution  1006927.1 :   Sun Fire[TM] 12K/15K/20K/25K : "EpiSchizoEccR1_sc_tfunc(): ALERT: DXs do not report seeing forced ECC" from SMS1.6 POST run  


Related Items
  • Sun Fire E25K Server
  •  
  • Sun Fire E20K Server
  •  
  • Sun Fire 12K Server
  •  
  • Sun Fire 15K Server
  •  
Related Categories
  • PLA-Support>Sun Systems>SPARC>Enterprise>SN-SPARC: SF-Exxk
  •  
  • .Old GCS Categories>Sun Microsystems>Servers>High-End Servers
  •  

PreviouslyPublishedAs
209596


Applies to:

Sun Fire E25K Server
Sun Fire 12K Server
Sun Fire 15K Server
Sun Fire E20K Server
All Platforms

Goal

The HOST POST (hpost) application is responsible for probing, testing and configuring the hardware of a Sun Fire[TM] 12K/15K/20K/25K domain, preparing it for use by the OpenBoot[TM] PROM and the Solaris[TM] Operating Environment (Solaris OS).

The Sun Fire 12K-25K platform's /opt/SUNWSMS/bin/hpost executable houses both the power-on self-test (POST) as well as the necessary logic involved in sequencing POST's operations.

Solution

Sun Fire 12K/15K/20K/25K platform with System Controller loaded with SMS 1.6 observed the following POST log verbiage when high level POST (level 64 or greater) is applied to resident domains.

For example, a domain with the following resources assigned:
SB5         On     V3CPU           Active        Passed        D
IO5 On HPCI+ Active Passed D


When subjected to a level 64 POST run will report the following:
# hpost version   1.6 GENERIC Apr 17 2006 11:33:03
# libxcpost.so v. 1.6 GENERIC Apr 17 2006 11:17:26
# pid = 17890 level = 64 verbose_level = 20
...
stage pci_lpost: Test all L1 I/O boards...
Performing ASIC config with bus config a/d/r = 333...
Slot0 in domain: 00020
Slot1 in domain: 00020
EXBs in use: 17F19
pcilpost.elf Version 5.20.0 Build 15.1 I/F 12 is newest supported
Slot SB5: EpiSchizoEccR1_sc_tfunc(): ALERT: DXs do not report seeing forced ECC
Slot IO5: EpiSchizoEccR1_sc_tfunc(): ALERT: DXs do not report seeing forced ECC
Slot SB5: EpiSchizoEccR1_sc_tfunc(): ALERT: DXs do not report seeing forced ECC
Slot IO5: EpiSchizoEccR1_sc_tfunc(): ALERT: DXs do not report seeing forced ECC


The "EpiSchizoEccR1_sc_tfunc(): ALERT: DXs do not report seeing forced ECC" logs reported from the level 64 POST run had stemmed from an incorrect behavior on the part the hpost routine responsible for implementing the PCI IOC ECC diagnostics cycle.
Given that this specific diagnostics cycle is only implemented on level 64 (or greater) POST runs, it would mean that "EpiSchizoEccR1_sc_tfunc(): ALERT: DXs do not report seeing forced ECC" logs would only be observed on POST runs that are initiated at level 64 (or greater).

As observed from the above level 64 POST run logs - the "EpiSchizoEccR1_sc_tfunc(): ALERT: DXs do not report seeing forced ECC" verbiage has no material impact on the outcome of the POST run, as the high level POST run completed w/o any apparent difference in the expected outcome. Hence, the recommended course of action against the above informational messages logged to the POST run logs is to ignore the "ALERT" messages.

These messages are filtered with Patch ID 124319-01 or above.

Product
Sun Fire E25K Server
Sun Fire E20K Server
Sun Fire 15K Server
Sun Fire 12K Server

Internal section

Keywords: EpiSchizoEccR1_sc_tfunc, DX, ALERT, ECC, hpost, SMS 1.6, post, asic_dx_eccerr_ctl, starcat, amazon

Previously Published As 87067

Product_uuid
d842dd03-059b-11d8-84cb-080020a9ed93|Sun Fire E25K Server
1404a2d3-059a-11d8-84cb-080020a9ed93|Sun Fire E20K Server
29e4659c-0a18-11d6-9fa1-e67bbc033df8|Sun Fire 15K Server
077fd4c5-df8f-4320-ad69-7d01603a674d|Sun Fire 12K Server



Attachments
This solution has no attachment
  Copyright © 2012 Sun Microsystems, Inc.  All rights reserved.
 Feedback