Sun Microsystems, Inc.  Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1006468.1
Update Date:2012-07-30
Keywords:

Solution Type  Technical Instruction Sure

Solution  1006468.1 :   How to find the firmware revision (fcode version) of on-board ISP2200 chip  


Related Items
  • Sun Fire V480 Server
  •  
  • Sun Fire V880z Visualization Server
  •  
  • Sun Fire V890 Server
  •  
  • Sun Fire V880 Server
  •  
  • Sun Fire V490 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>SPARC>Usx/Blade/Netra>SN-SPARC: USx
  •  
  • .Old GCS Categories>Sun Microsystems>Servers>Entry-Level Servers
  •  

PreviouslyPublishedAs
209063


Applies to:

Sun Fire V480 Server
Sun Fire V490 Server
Sun Fire V880 Server
Sun Fire V880z Visualization Server
Sun Fire V890 Server
All Platforms

Goal

Ever need to find out the fcode version of the on-board ISP2200 chip?

Solution

Steps to Follow
The luxadm command will provide this information in a succinct output.
Example:


# luxadm qlgc_s_download

Found Path to 1 FC100/P, ISP2200 Devices

Opening Device: /devices/pci@8,600000/SUNW,qlc@2/fp@0,0:devctl
Detected FCode Version: ISP2200 FC-AL Host Adapter Driver: 1.14 01/11/20 Complete



The Fcode version in the example is 1.14

Most probably, once you've found the firmware revision, the next logical question will be how to update the firmware.  The only way to update the on-board firmware for the ISP2200 is to update the OBP.  


See <Sunbug 4454917>  for more information on why.


See <Document 1007526.1> for information on updating the OBP.