Sun Microsystems, Inc.  Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1005062.1
Update Date:2012-07-30
Keywords:

Solution Type  Technical Instruction Sure

Solution  1005062.1 :   Sun StorEdge 3310, 3320, 3510, and 3511 Arrays: How to use the sccli command to configure and unconfigure Global Spare Disks  


Related Items
  • Sun Storage 3510 FC Array
  •  
  • Sun Storage 3310 Array
  •  
  • Sun Storage 3511 SATA Array
  •  
  • Sun Storage 3320 SCSI Array
  •  
Related Categories
  • PLA-Support>Sun Systems>DISK>Arrays>SN-DK: SE31xx_33xx_35xx
  •  
  • .Old GCS Categories>Sun Microsystems>Storage - Disk>Modular Disk - 3xxx Arrays
  •  

PreviouslyPublishedAs
207118


Applies to:

Sun Storage 3310 Array
Sun Storage 3510 FC Array
Sun Storage 3511 SATA Array - Version: Not Applicable to Not Applicable   [Release: N/A to N/A]
Sun Storage 3320 SCSI Array - Version: Not Applicable to Not Applicable   [Release: N/A to N/A]
All Platforms

Goal

Description


This document shows the procedures to configure and unconfigure global spares using the Sun StorEdge 3000 Family CLI 2.x "sccli" command.



Solution

Steps to Follow:


Use help to see the unconfigure syntax:

sccli> help unconfigure
   unconfigure {local-spare|global-spare}  []
unconfigure a local or global spare drive

How to unconfigure the global spare disk :

 sccli> show disks
Ch Id Size Speed LD Status IDs
-----------------------------------------------------------------------
2 6 232.88GB 200MB ld1 ONLINE HITACHI HDS7225SASUN250G A6DA
S/N VNRJ9HC6CTL4UM
2 7 232.88GB 200MB ld1 ONLINE HITACHI HDS7225SASUN250G A6DA
S/N VNRJ9HC6CTKH6M
2 8 232.88GB 200MB ld1 ONLINE HITACHI HDS7225SASUN250G A6DA
S/N VNRJ9HC6CT8GWM
2 9 232.88GB 200MB ld1 ONLINE HITACHI HDS7225SASUN250G A6DA
S/N VNRJ9HC6CT9T5M
2 10 232.88GB 200MB ld1 ONLINE HITACHI HDS7225SASUN250G A6DA
S/N VNRJ9HC6CTEHZM
2 11 232.88GB 200MB GLOBAL STAND-BY HITACHI HDS7225SASUN250G A6DA
S/N VNRJ9HC6CTH1DM
 sccli> unconfigure global-spare 2.11
 sccli> show disks
Ch Id Size Speed LD Status IDs
-----------------------------------------------------------------------
2 6 232.88GB 200MB ld1 ONLINE HITACHI HDS7225SASUN250G A6DA
S/N VNRJ9HC6CTL4UM
2 7 232.88GB 200MB ld1 ONLINE HITACHI HDS7225SASUN250G A6DA
S/N VNRJ9HC6CTKH6M
2 8 232.88GB 200MB ld1 ONLINE HITACHI HDS7225SASUN250G A6DA
S/N VNRJ9HC6CT8GWM
2 9 232.88GB 200MB ld1 ONLINE HITACHI HDS7225SASUN250G A6DA
S/N VNRJ9HC6CT9T5M
2 10 232.88GB 200MB ld1 ONLINE HITACHI HDS7225SASUN250G A6DA
S/N VNRJ9HC6CTEHZM
2 11 232.88GB 200MB NONE FRMT HITACHI HDS7225SASUN250G A6DA
S/N VNRJ9HC6CTH1DM

At this point we have unconfigured the Global Spare Disk.

Steps to configure it again are:

 sccli>  help configure global-spare
configure global-spare configure a disk as a global spare
 sccli> configure global-spare 2.11

See the : Sun StorEdge 3000 Family CLI 2.5 User’s Guide (817-4951)
for details.


Change History
Date: 2010-06-28
User Name: [email protected]
Action: Currency and update

Attachments
This solution has no attachment
  Copyright © 2012 Sun Microsystems, Inc.  All rights reserved.
 Feedback