Sun Microsystems, Inc.  Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1004928.1
Update Date:2012-07-30
Keywords:

Solution Type  Technical Instruction Sure

Solution  1004928.1 :   How to Identify Fans in V240 and V210 Systems  


Related Items
  • Sun Fire V240 Server
  •  
  • Sun Fire V210 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>SPARC>Workgroup Servers>SN-SPARC: SF-V2x0
  •  
  • .Old GCS Categories>Sun Microsystems>Servers>Entry-Level Servers
  •  

PreviouslyPublishedAs
206913


Description
How to identify and locate fans on a V240 and v210.


Steps to Follow
On a V240 and V210 you will see the fans referred to as:
  F0.RS <- system fan 0
F1.RS <- system fan 1
F2.RS <- system fan 2
MB.P0.F0.RS or MB/P0/F0 <- motherboard fan 0 position 0
MB.P0.F1.RS or MB/P0/F1 <- motherboard fan 1 position 1
  MB.P1.F0.RS or MB/P1/F0 <- motherboard fan 0 position 0
MB.P1.F1.RS or MB/P1/F1 <- motherboard fan 1 position 1
    ex:  MB.P0.F0.RS would be cpu0's fan0 on the mb and not
one of the system fans

System Fans:

Looking down on the V240 with the cover removed, and the front to the
left, System fan 0 is on top, system fan 1 is in the middle and system
fan 2 is on the bottom. With v210 system fan 0 is at the top and 3 is on the bottom.
Unlike the V240, all 4 system fans for the V210 come on a fan tray as a FRU

See:

https://support.oracle.com/handbook_private/Systems/SunFireV240/component.top.html

https://support.oracle.com/handbook_private/Systems/SunFireV210/component.top.html

CPU fans:

Looking down on the system board with the external connections at the
bottom: This is the same for V210 and V240 as they use the same system boards

MB.P0.F0.RS is the left fan of processor 0 (bottom processor) and
MB.P0.F1.RS is the right fan of processor 0 (bottom processor)
MB.P1.F0.RS is the left fan of processor 1 (top processor) and
MB.P1.F1.RS is the right fan of processor 1 (top processor).

See:

https://support.oracle.com/handbook_private/Devices/System_Board/SYSBD_SunFireV2x0_CPU.html



Product
Sun Fire V240 Server

Internal Comments
Audited/updated 12/02/09 - [email protected], Entry Level SPARC Content Team Member




V240, fan, F0.RS, F1.RS, MB.P0.F0.RS, MB.P0.F1.RS, MB.P1.F0.RS, MB.P1.F1.RS
Previously Published As
76689

Change History
Corrected the motherboard fan positions per [email protected] request on 6/4/09

should be:

MB.P0.F0.RS or MB/P0/F0 <- motherboard fan 0 position 0
MB.P0.F1.RS or MB/P0/F1 <- motherboard fan 1 position 1

MB.P1.F0.RS or MB/P1/F0 <- motherboard fan 0 position 0
MB.P1.F1.RS or MB/P1/F1 <- motherboard fan 1 position 1

Date: 2005-04-20
User Name: 97961
Action: Accept
Comment:
Version: 0