Goal

This document is meant to be a quick reference guide to show the SSP file system layout in an E10K configuration. The purpose of this document is as a reference which details the location of critical files required for troubleshooting problems quickly.

Fix

SSP File System Layout

$SSPVAR   (/var/opt/SUNWssp)
- .ssp_private
|    cb_config (output from ssp_config)
|    cb_port
|    domain_config (output from domain_create)
|    domain_history
|    ssp_resource
|    ssp_to_domain_hosts (output from ssp_config)
|    main_ssp_name (floating name and IP)
|    fad_files
|
|__eeprom_save
|       eeprom.image.<domain-name>
|       eeprom_image_1
|
- adm
|     messages (platform messages)
|     netcon
|
|__  domain_name
|         |     messages
|         |     netcon
|         |     xfstate-files
|         |     Edd-Arbstop-Dump-files
|         |     Edd-Record-Stop-Dump-files
|         |
|         |__  post
|                post1024.0908.log (log files for hpost)
- etc
|__  platform_name
     |     blacklist (used to disable components on next bringup)
     |     edd.erc
     |     edd.emc
     |
     |__  domain_name
                      bootproc ( contains the bootproc number)
                      edd.erc
                      eeprom.image (working copy)
                      eeprom.backup.1 (backups, not archives)
                      eeprom.backup.2 (backups, not archives)
                      .postrc
- pids (process ids of server apps)
- data (scantool files updated by autoconfig)
- ict  (interconnect test results)


Product
System Service Processor 3.5
System Service Processor 3.4 (Localized)
System Service Processor 3.4 (English)
System Service Processor 3.3
System Service Processor 3.1
Sun Enterprise 10000 Server

Internal Section

Published internally here (has.us)

Similar document for Sun Fire[TM] 15000 SMS File System Layout is Problem Resolution document 1003299.1

Keywords: $SSPVAR, ssp

Previously Published As 71715

Product_uuid
837821c8-9ae0-4e3c-8ee2-5f80eed3f977|System Service Processor 3.5
afa2f34a-2bd5-11d6-983f-de843a2c219a|System Service Processor 3.4 (Localized)
af987870-2bd5-11d6-9cc8-c799d5cf7ed3|System Service Processor 3.4 (English)
b2448136-2bd5-11d6-85ce-9bcbc88fff45|System Service Processor 3.3
a3deebd6-2bd5-11d6-9d5b-db171ac7152c|System Service Processor 3.1
29ddef46-0a18-11d6-92de-ae47474f0f6c|Sun Enterprise 10000 Server

 


Attachments
This solution has no attachment
  Copyright © 2012 Sun Microsystems, Inc.  All rights reserved.
 Feedback