![]() | Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Technical Instruction Sure Solution 1004453.1 : Sun Enterprise[TM] 10000: How to run hpost on system board with no I/O configured
PreviouslyPublishedAs 206148
Applies to:Sun Enterprise 10000 ServerAll Platforms GoalHow to run hpost on system board with no I/O configured.SolutionWhen running hpost on a standalone system board which doesn't have any Sbus cards, hpost will fail as follows :phase iom_probe: I/O module type probe... To allow the system board to run without any I/O, simply add the following entry to the .postrc file for the domain. no_scards_ok This file is located in /var/opt/SUNWssp/etc///.postrc. Similar issues with system boards without memory can be avoided by adding the entry to the .postrc file: no_memory_ok Product Sun Enterprise 10000 Server Internal Section Keywords: E10000, hpost, ecode 76, .postrc, unable, configure bootable system, post, failure Previously Published As 19897 Attachments This solution has no attachment |
||||||||||||
|