Sun Microsystems, Inc.  Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1004453.1
Update Date:2012-07-30
Keywords:

Solution Type  Technical Instruction Sure

Solution  1004453.1 :   Sun Enterprise[TM] 10000: How to run hpost on system board with no I/O configured  


Related Items
  • Sun Enterprise 10000 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>SPARC>Enterprise>SN-SPARC: SF-Exxk
  •  
  • .Old GCS Categories>Sun Microsystems>Servers>High-End Servers
  •  

PreviouslyPublishedAs
206148


Applies to:

Sun Enterprise 10000 Server
All Platforms

Goal

How to run hpost on system board with no I/O configured.

Solution

When running hpost on a standalone system board which doesn't have any Sbus cards, hpost will fail as follows :

phase iom_probe: I/O module type probe...
No minimum system left after I/O module type probe! Bailing out!
... board dump ...
Exitcode = 76: Unable to configure a bootable system


To allow the system board to run without any I/O, simply add the following entry to the .postrc file for the domain.
no_scards_ok

This file is located in /var/opt/SUNWssp/etc///.postrc.

Similar issues with system boards without memory can be avoided by adding the entry to the .postrc file:
no_memory_ok

Product
Sun Enterprise 10000 Server


Internal Section

Keywords: E10000, hpost, ecode 76, .postrc, unable, configure bootable system, post, failure