![]() | Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Technical Instruction Sure Solution 1003646.1 : Connecting your console to a Sun Fire[TM]/Netra[TM] 1280/1290/E2900 serial LOM port
PreviouslyPublishedAs 205148
Applies to:Sun Netra 1280 ServerSun Fire V1280 Server Sun Fire E2900 Server Sun Netra 1290 Server - Version: Not Applicable and later [Release: N/A and later] All Platforms GoalThis document gives the part numbers of the adapters needed to properly attach a console to the RJ45 Sunfire 1280/2900 serial LOM port.Solution1. Connect the RJ45-to-RJ45 straight-thru network cable (supplied with the server) to the Serial A/LOM port on the back panel of the 1280/2900 server. This port will be labeled "SSC1 Serial A".2. Connect the other end of the network cable to the RJ45 connector on the silver-colored DB25/RJ45 adapter (part number 530-2889-0x) supplied with the server. If your console has a DB25 connector, use part number 530-3100. Sunfire/Netra 1280 Serial Port Pin-outs 8-Pos RJ45 25-pin DSUB Product Sun Fire E2900 Server Sun Fire V1280 Server Netra 1280 Server Internal Comments This Technical Instruction applies to most Sun[TM] servers that have an RJ45 serial port, ie, rsc card on Sunfire[TM] 280/480/880, Netra T servers. lom, sc, console, serial Previously Published As 80886 Attachments This solution has no attachment |
||||||||||||
|