Sun Microsystems, Inc.  Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1002176.1
Update Date:2012-07-30
Keywords:

Solution Type  Technical Instruction Sure

Solution  1002176.1 :   Updating BIOS/Firmware error on Sun Fire[TM] v20z/v40z error: Port out of range...please select a valid port( 49152 - 65535 )  


Related Items
  • Sun Fire V20z Server
  •  
  • Sun Fire V40z Server
  •  
Related Categories
  • PLA-Support>Sun Systems>x64>Server>SN-x64: SERVER 64bit
  •  
  • .Old GCS Categories>Sun Microsystems>Servers>x64 Servers
  •  

PreviouslyPublishedAs
203085


Description
This Read Me provides instructions on updating the BIOS and SP firmware for the Sun Fire[TM] V20z and Sun Fire[TM] V40z servers.
PDF: 819-2714-14 SP and BIOS Update ReadMe -  November 2006

Steps to Follow
This document contains instructions on how to update the BIOS and SP firmware in
the Sun Fire[TM] V20z and Sun Fire V40z servers.
Please note on page 11 (Page 14 in Acrobat Reader) and page 18 (Page 22 in Acrobat Reader) of the 819-2714-14.pdf that you should use port 50000 instead of port 1234:

Page 10:

Sun Fire V20z server:

java -jar /export/home/v20z/update_server/V2.2.0.6/updateServer.jar -f /export/home/v20z/sw_images/sp/spbase/V2.2.0.18/install.image -p 50000

Sun Fire V40z server:

java -jar /export/home/v40z/update_server/V2.2.0.6/updateServer.jar -f /export/home/v40z/sw_images/sp/spbase/V2.2.0.18/install.image -p 50000

sp update flash all -i <ip_address_solaris_machine> -p 50000

Page 18:

Sun Fire V20z server:

java -jar /export/home/v20z/update_server/V2.2.0.6/updateServer.jar -f /export/home/v20z/sw_images/sp/spbase/V2.2.0.18/install.image -p 50000

Sun Fire V40z server:

java -jar /export/home/v40z/update_server/V2.2.0.6/updateServer.jar -f /export/home/v40z/sw_images/sp/spbase/V2.2.0.18/install.image -p 50000

sp update flash all -i <ip_address_linux_machine> -p 50000

Using port 1234 will give this error message:

Error. Port out of range...please select a valid port (49152 - 65535).

***Checked for relevance on 22-Nov-2011*** Previously Published As 81421