Sun Microsystems, Inc.  Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-79-1454231.1
Update Date:2012-04-30
Keywords:

Solution Type  Predictive Self-Healing Sure

Solution  1454231.1 :   Niwot SAS cable pinout differs from system board SAS cable  


Related Items
  • Netra SPARC T4-1 Server
  •  
  • SPARC T4-1
  •  
  • SPARC T3-1
  •  
Related Categories
  • PLA-Support>Sun Systems>SPARC>CMT>SN-SPARC: T3
  •  




Applies to:

SPARC T3-1
Netra SPARC T4-1 Server
SPARC T4-1
Information in this document applies to any platform.

Purpose

Niwot SAS cable differs from system board SAS cable 

Details

When adding a Sun Storage 6Gb SAS PCIe RAID HBA Internal Card (Niwot) to a system, please note that its SAS cable pinout differs from the SAS cable that connects to a system board.  The Niwot SAS cable must be used when connecting it to the disk backplane.  Also, if a Niwot is removed, the SAS cable listed in the Sun System handbook must be used to connect the system board to the disk backplane.