![]() | Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Predictive Self-Healing Sure Solution 1454231.1 : Niwot SAS cable pinout differs from system board SAS cable
Applies to:SPARC T3-1Netra SPARC T4-1 Server SPARC T4-1 Information in this document applies to any platform. PurposeNiwot SAS cable differs from system board SAS cable DetailsWhen adding a Sun Storage 6Gb SAS PCIe RAID HBA Internal Card (Niwot) to a system, please note that its SAS cable pinout differs from the SAS cable that connects to a system board. The Niwot SAS cable must be used when connecting it to the disk backplane. Also, if a Niwot is removed, the SAS cable listed in the Sun System handbook must be used to connect the system board to the disk backplane. Attachments This solution has no attachment |
||||||||||||
|