Asset ID: |
1-79-1388482.1 |
Update Date: | 2012-07-16 |
Keywords: | |
Solution Type
Predictive Self-Healing Sure
Solution
1388482.1
:
Sun SPARC Enterprise Server E3000/E3500/E4000/E4500/E5000/E5500/E6000/E6500 ( SunFire Classic ): Cheat Sheet
Related Items |
- Sun Enterprise 5500 Server
- Sun Enterprise 4000 Server
- Sun Enterprise 5000 Server
- Sun Enterprise 3000 Server
- Sun Enterprise 3500 Server
- Sun Enterprise 6000 Server
- Sun Enterprise 6500 Server
- Sun Enterprise 4500 Server
|
Related Categories |
- PLA-Support>Sun Systems>SPARC>Enterprise>SN-SPARC: Exx00
- .Old GCS Categories>Sun Microsystems>Servers>Midrange V and Netra Servers
|
In this Document
Oracle Confidential (PARTNER). Do not distribute to customers.
Reason: migrated http://panacea.uk.oracle.com/twiki/bin/view/Products/SunEnterpriseCheatSheet
Applies to:
Sun Enterprise 4000 Server - Version Not Applicable and later
Sun Enterprise 3000 Server - Version Not Applicable and later
Sun Enterprise 3500 Server - Version Not Applicable and later
Sun Enterprise 4500 Server - Version Not Applicable and later
Sun Enterprise 5000 Server - Version Not Applicable and later
Information in this document applies to any platform.
Purpose
Classic Product Line Cheat Sheet
Details
front E3x00 |
front E4x00 |
Front E5x00/E6x00 |
Rear E3x00 |
Rear E4x00 |
Rear E5x00/6x00 |
Data Collection
Collect explorer for most every issue.
- See Oracle Explorer Data Collector - Product Information Center (Doc ID 1312847.1) for details.
Console logs need to be obtained for certain errors and are required to diagnose Fatal Reset/Fatal Error events.
How to identify the Physical DIMM size
Physical DIMM Size is equal to the "MB" entry in prtdiag divided by 8.
|
Important Resources
|
Memory DIMM Layout on System Board
 |
System LEDs
Basic Troubleshooting for Boards
- If the yellow LED (middle LED) is continuously lit (not flashing) the board may require service. Further analysis is needed to determine cause of failure.
- If the left and right green LEDs are off, the board is ready for removal.
- If no LEDs are flashing, the system is hung.
- If no LEDs are lit, there is no electrical power to the board.
|
References
<NOTE:1002383.1> - Oracle Explorer Data Collector for Sun systems
@<NOTE:1007940.1> - Analyzing and Troubleshooting UE errors on Enterprise[TM] E3x00-E6x00 systems
<NOTE:1008702.1> - Console Logging Options to capture Fatal Reset output for Sun systems
@<NOTE:1012819.1> - Sun Enterprise[TM] 3000/3500/4000/4500/5500/6000/6500: Troubleshooting Fatal Resets
Attachments
This solution has no attachment