  Purpose
  Sun Fire [TM] SF3800/SF4800/SF4810/SF6800 - E4900/E6900 Server ( Serengeti/Amazon ) system: Cheat Sheet


Oracle Confidential (PARTNER). Do not distribute to customers
Reason: migrated http://panacea.uk.oracle.com/twiki/bin/view/Products/SerengetiCheatSheet

Applies to:

Sun Fire 3800 Server - Version: Not Applicable and later   [Release: N/A and later ]
Sun Fire E6900 Server - Version: Not Applicable and later    [Release: N/A and later]
Sun Fire 4800 Server - Version: Not Applicable and later    [Release: N/A and later]
Sun Fire 4810 Server - Version: Not Applicable and later    [Release: N/A and later]
Sun Fire 6800 Server - Version: Not Applicable and later    [Release: N/A and later]
Information in this document applies to any platform.

Purpose

Serengeti Product Line Cheat Sheet

Sun Fire [TM] SF3800/SF4800/SF4810/SF6800 - E4900/E6900 Server ( Serengeti/Amazon ) system: Cheat Sheet

Data Collection

Collect explorer -w default,scextended,fru. See Document 1019066.1 for details.
When Explorer is not available, please manually collect the data specified in Document 1003529.1.




3800 Front


3800 Rear


4800/4900 Front


4800/4900 Rear



4810 Front


6800/6900 Front


6800/6900 Rear


Commonly Used SC & LOM Commands

See the Command Reference Guide for full details


setdefaults Sets the configuration back to default values setfailover Changes SC failover status (force switches Main SC control). setkeyswitch Change the keyswitch position.
addboard / deleteboard Assigns / Un-assigns a board to a domain (DR) break send break to the Solaris console console connect to the Solaris console
history show command history password set the SC (or LOM) access password poweron / poweroff power on system / components and start OBP
poweron all poweron all system / components only reboot Reboots the System Controller reset reset the Solaris system
resume Exits the domain shell & resumes access to the domain console. setchs / showchs set / show FRU Component Health Status (setchs available only in service mode <5.20.15) </td> setdate / showdate set / show the date and time for the system
disablecomponent / enablecomponent add / remove a component from the blacklist flashupdate update firmware (scapp) help show help for a command or a list of commands
showcomponent Show state of a component showenvironment Show environmental information showerrorbuffer Show the contents of the error buffer
setupdomain Configures the domain setupplatform / showplatform Configures / Shows the platform configuration showboards Shows board information
showlogs Show the error logs (-v option should be used). showsc Show SC version and uptime information testboard / testinterconnect Test a board or run interconnect test (service mode commands)


Connecting to the SC from an admin workstation:

  Use a serial port connection:
      # tip hardwire

  Use telnet (assumes SC net has been configured
  with setupnetwork):
       # telnet SC-hostname or IP address

  Use SSH:
       admin-ws% ssh 6800-sc1
       Enter Password: As setup
       Connected. HIT RETURN

Note – At 5.18.0, you will be offered the option of connecting with a
secure shell (ssh) only if you have an SC V2 in the IB/SSC.
In this case only SSH will work not telnet



How to send a break if connected to the SC:

See Document 1017808.1 for details.




Navigating between shells


Click image to see knowledge article on topic.
Navigating Shells Image


POST levels (Change using diag-level?)

  init  - (Default level) Only initialization code is
          run, no testing.
  quick - Few tests and few patters.
  min   - Quick sanity check.
  max   - All components tested with all tests and
          patterns, except for memory & Ecache.
  mem1  - More exhaustive DRAM and SRAM tests.
  mem2  - mem1 with the addition of a DRAM.



How to Identify the Physical DIMM Size:

  - Physical Size is equal to "DIMM Size" in prtdiag.
  - prtfru_-x.out data in Explorer identifies the 
    DIMM size.
  - sc>showboards -p memory identifies the DIMM size.


How to Identify the CPU Speed:

  - sc>showboards -v -p cpu shows the CPU speed.
  - prtdiag identifies the CPU speed..
  - prtfru_-x.out data in Explorer identifies CPU 
    speed and the board type.
  - showlogs AD Event messaging does NOT identify 
    the correct FRU pn for a SB.


System Indicators (LEDs)

Click on the pictures to be taken to the Sun Fire Servers LED Page

System LEDs Image



Power Supply Units (L-R: 3800, 4800/4900, 4810/6800/6900)


Serengeti PSU Image


DIMM Layout on Board


Click the picture to see an enlarged image.
DIMM Layout Image