Sun Microsystems, Inc.  Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-79-1385820.1
Update Date:2012-03-12
Keywords:

Solution Type  Predictive Self-Healing Sure

Solution  1385820.1 :   Sun Fire [TM] V1280/E2900, Netra 1280/1290 ( LW8/Amazon/Everglades ) system: Cheat Sheet  


Related Items
  • Sun Netra 1290 Server
  •  
  • Sun Fire V1280 Server
  •  
  • Sun Fire E2900 Server
  •  
  • Sun Netra 1280 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>SPARC>Enterprise>SN-SPARC: Exx00
  •  
  • .Old GCS Categories>Sun Microsystems>Servers>Midrange V and Netra Servers
  •  




In this Document
  Purpose
  Sun Fire [TM] V1280/E2900, Netra 1280/1290 ( LW8/Amazon/Everglades ) system: Cheat Sheet


Oracle Confidential (PARTNER). Do not distribute to customers
Reason: migrated http://panacea.uk.oracle.com/twiki/bin/view/Products/Lw8CheatSheet

Applies to:

Sun Fire V1280 Server - Version: Not Applicable and later   [Release: N/A and later ]
Sun Netra 1280 Server - Version: Not Applicable and later    [Release: N/A and later]
Sun Netra 1290 Server - Version: Not Applicable and later    [Release: N/A and later]
Sun Fire E2900 Server - Version: Not Applicable and later    [Release: N/A and later]
Information in this document applies to any platform.

Purpose

Lightweight8 (Lw8) Product Line Cheat Sheet

Sun Fire [TM] V1280/E2900, Netra 1280/1290 ( LW8/Amazon/Everglades ) system: Cheat Sheet

Data collection

Collect explorer -w default,1280extended,fru. See Document 1019066.1 for details.
When Explorer is not available, please manually collect the data specified in Document 1003529.1.



front


top


rear



Commonly Used SC & LOM Commands

See the Command Reference Guide for full details


logout logout from this connection showenvironment show environmental information disablecomponent add a component to the blacklist
console connect to the Solaris console showdate show the current date and time setupsc configure the SC (lom)
reset reset the Solaris system showerrorbuffer show the contents of the error buffer enablecomponent remove a component from the blacklist
shutdown shutdown Solaris and take to standby mode help show help for a command or a list of commands testinterconnect run interconnect test
showsc show SC (or LOM) version and uptime history show command history setchs set FRU Component Health Status (Only available in service mode <5.20.15) </td>
poweroff power off system or component showcomponent show state of a component setdate set the date and time for the system
poweron power on system / components and start OBP poweron all poweron all system / components only password set the SC (or LOM) access password
Break send break to the Solaris console shownetwork show SC (or LOM) network settings and MAC addresses setupnetwork setup SC (or LOM) network settings
showlogs show the logs flashupdate update firmware (scapp) showchs show FRU Component Health Status
resetsc reset the SC (or LOM) showfault show fault information testboard test a CPU/Memory board
inventory show seeprom contents of a FRU showboards show board information lom -G update firmware (using lom)

Connecting to the SC from an admin workstation:

  Use a serial port connection:
       # tip hardwire

  Use the telnet command (assumes SC net has been configured with setupnetwork):
       # telnet SC-hostname or IP address

  Use SSH:
       admin-ws% ssh v1280-sc1
       Enter Password: As setup by the lom> password command
       Connected. HIT RETURN

Note – At 5.18.0, you will be offered the option of connecting with a
secure shell (ssh) only if you have an SC V2 in the IB/SSC.
In this case only SSH will work not telnet


POST levels (Change using diag-level?)

  init - (Default level) Only initialization code is
         run, no testing.
  quick - Few tests and few patters.
  min - Quick sanity check.
  max - All components tested with all tests/patterns,
        except for memory and Ecache modules.
  mem1 - More exhaustive DRAM and SRAM tests.
  mem2 - mem1 with the addition of a DRAM.

Navigating between shells

See also Sun Fire[TM] 3800, 4800, 4810, 6800, E4900, and E6900: Navigating Between Shells on Sun Fire Mid-range Servers [Video] (Doc ID 1003150.1)

Navigating Shells Image

How to Identify the Physical DIMM Size:

  - Physical DIMM Size is equal to the "Size" entry
    in prtdiag divided by 2.
  - lom>inventory identifies the DIMM size and part 
    number.
  - prtfru_-x.out data in Explorer identifies the 
    DIMM size.
  - lom>showboards -p memory identifies the DIMM size.

How to Identify the CPU Speed:

  - lom>showboards -v -p cpu shows the CPU speed.
  - prtdiag identifies the CPU speed..
  - prtfru_-x.out data in Explorer identifies CPU 
    speed and the board type.
  - showlogs AD Event messaging does NOT identify 
    the correct FRU pn for a SB.

System Indicators (left); PSU LEDs (right)


Click on the pictures to be taken to the Lw8 Systems LED Page
System LEDs Image


DIMM Layout on Board


DIMM Layout Image

Attachments
This solution has no attachment
  Copyright © 2012 Sun Microsystems, Inc.  All rights reserved.