Sun Microsystems, Inc.  Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-79-1380664.1
Update Date:2012-08-16
Keywords:

Solution Type  Predictive Self-Healing Sure

Solution  1380664.1 :   Sun Storage F5100 Flash Array Firmware Matrix  


Related Items
  • Sun Flash F5100 Array
  •  
  • Sun Storage Common Array Manager (CAM)
  •  
Related Categories
  • PLA-Support>Sun Systems>DISK>SSD Flash>SN-DK: F5100 F20 Flash
  •  


Sun Storage F5100 Flash Array Firmware Matrix

In this Document
Purpose
Scope
Details


Applies to:

Sun Storage Common Array Manager (CAM) - Version 6.4 and later
Sun Flash F5100 Array - Version Not Applicable and later
Information in this document applies to any platform.

Purpose

Cross-reference matrix for Sun Storage F5100 Array firmware and Sun Storage Common Array Manager (CAM) version.

Scope

Support engineers, Field engineers, Customers

Details

Firmware Matrix for F5100 and CAM

Sun Storage F5100 Flash Array (LF1.0 PANDORA) Firmware
CAM releasePatchFishwrap APIFPGASAS Expander (1.0 Pandora)FMOD (SATA)
CAM releasePatchFishwrap APIFPGASAS Expander (1.0 Pandora)FMOD (SATA)
  No Support
1.x
2.x
5.x
6.0.x
6.1.x
6.2.x
6.3.0   CAM 6.3 was never released.
6.4.0.10 a no support 2.7.0-1 2.2 5.3.71.0 (0347) S11L
6.4.1.5 b   2.8.6.1 2.2 5.3.73.0 (0349) MP01c
6.4.1.5 141484-01d
141485-01 
141486-01 
  MP1F
6.5.0.10   2.8.10.1 2.2 5.3.73.0 (0349) MP1F
6.5.0.11 141581-01 CAM core patch for Windows only.
6.5.0.x 142798-01
142799-01
142800-01
 
6.5.0.13 141580-02
141581-02
141582-02
CAM core patch -02; various fixes.
6.5.0.13 142798-02
142799-02
142800-02
 
6.6.0.11   3.5.2-1 2.2 5.3.73.0 (0349) D10R
6.6.0.12 141474-01
141475-01
141476-01
 
6.6.0.12 143759-01
143760-01
143761-01
 
6.7.0.12   3.7.0-4 2.2 5.3.73.0 (0349) D11B
6.7.0.13 144861-01 CAM core patch for Windows only
6.7.0.x 145965-01
145966-01
145967-01
Firmware patch for F5100 LF1.0 ERIE SAS Expander.
6.7.0.x 145965-02
145966-02
145967-02
 
6.7.0.x 145965-03
145966-03
145967-03
F5100 LF1.0 ERIE FMOD firmware fixes FMODs zombie during db restore operation. (Includes all previous fixes in 14596[567]-*.)
6.7.0.14 144860-02g 3.7.4-3  
6.8.0.20   3.7.4-3 2.2 5.3.73.0 (0349) D129
6.8.1.4   3.7.4-3 2.2 5.3.73.0 (0349)

D129

6.9.0.x   3.7.4-3 2.2 5.3.73.0 (0349)

D129

 

Sun Oracle Storage F5100 (aka F5100B) Flash Array (LF1.0 ERIE) Firmware
CAM releasePatchFishwrap APIFPGASAS Expander (LF1.0 Erie)FMOD (SATA)
CAM releasePatchFishwrap APIFPGASAS Expander (LF1.0 Erie)FMOD (SATA)
  No Support
1.x
2.x
5.x
6.0.x
6.1.x
6.2.x
6.4.x
6.5.x
6.6.0.11 no support 3.5.2-1 2.4 5.4.4.0 (0404) D10R
6.6.0.12 141474-01
141475-01
141476-01
 
6.6.0.12 143759-01
143760-01
143761-01
 
6.7.0.12 no support 3.7.0-4 2.4 5.4.4.0 (0404) D11B
6.7.0.13 144861-01 CAM core patch for Windows only.
6.7.0.x 145965-01e
145966-01 
145967-01 
3.7.2-1 2.4 5.4.5.0 (0405) D11B
6.7.0.x 145965-02 
145966-02 
145967-02 
3.7.2-1 2.4 5.4.5.0 (0405) D11B
6.7.0.x 145965-03f
145966-03 
145967-03 
3.7.2-1 2.4 5.4.5.0 (0405) D129
6.7.0.14 144860-02g 3.7.4-3  
6.8.0.20   3.7.4-3 2.4 5.4.5.0 (0405) D129
6.8.1.4   3.7.4-3 2.4 5.4.5.0 (0405) D129
6.9.0.x   3.7.4-3 2.4 5.4.5.0 (0405) D129
Note "controlled" items are not publicly available and are provided on case-by-case basis upon consultation with backline and/or engineering.
a CAM 6.4.0.10 does NOT support F5100/J4000/B6000! It was released urgently due to SA256288 for 6000/2500 and skipped over 6.3.0 which was in development for support of SAS Zoning and F5100, consequently F5100 related packages bundled in 6.4.0 was not ready for release.
b CAM 6.4.1.5 restored support for J4000/B6000 and add support for SAS Zoning and F5100.
c F5100 FMOD was released with MP1F, but CAM 6.4.1.5 was released with an older MP01, a later CAM firmware patch will fix this.
d Firmware patch 14148[456]-01 is required with CAM 6.4.1.5 to support F5100.
e Firmware patch 14596[567]-01 is required with CAM 6.7.0 to support F5100 LF1.0 Erie; on Windows platforms, core patch 144861-01 is also required.
f Firmware patch 14596[567]-03 contains F5100 LF1.0 ERIE FMOD firmware, fixes FMODs zombie during db restore operation. (Includes all previous fixes in 14596[567]-*. Patch -02 not relevant to F5100.)
g Patch 144860-02 is for CAM 6.7.0.12 on Solaris/SPARC only, CAM version becomes 6.7.0.14. Fishwrap 3.7.4-3 bug fixes.

Attachments
This solution has no attachment
  Copyright © 2012 Sun Microsystems, Inc.  All rights reserved.
 Feedback