Sun Microsystems, Inc.  Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-79-1368688.1
Update Date:2012-07-17
Keywords:

Solution Type  Predictive Self-Healing Sure

Solution  1368688.1 :   Sun SPARC(R) Enterprise M3000/M4000/M5000/M8000/M9000 (OPL) Servers: Archived Issues Page  


Related Items
  • Sun SPARC Enterprise M9000-64 Server
  •  
  • Sun SPARC Enterprise M9000-32 Server
  •  
  • Sun SPARC Enterprise M8000 Server
  •  
  • Sun SPARC Enterprise M3000 Server
  •  
  • Sun SPARC Enterprise M5000 Server
  •  
  • Sun SPARC Enterprise M4000 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>SPARC>Enterprise>SN-SPARC: Mx000
  •  
  • .Old GCS Categories>Sun Microsystems>Servers>OPL Servers
  •  




In this Document
Purpose
Details
 Hardware
 XCP Issue
 IO Issue
 DR Issue
References


Oracle Confidential (PARTNER). Do not distribute to customers.
Reason: Internal Only Information

Applies to:

Sun SPARC Enterprise M3000 Server - Version Not Applicable and later
Sun SPARC Enterprise M5000 Server - Version Not Applicable and later
Sun SPARC Enterprise M8000 Server - Version Not Applicable and later
Sun SPARC Enterprise M9000-32 Server - Version Not Applicable and later
Sun SPARC Enterprise M9000-64 Server - Version Not Applicable and later
Information in this document applies to any platform.

Purpose

This document provides a listing of archived issue known to affect the OPL platform.
Current and Active issues are at 1315765.1
Also check the XCP release notes for known issues.

Details

Sparc Home Product Issues   Patches/Firmware   Training/Knowledge    I/O Expansion
Documentation  M3000 M4000 M5000 M8000 M9000
SSH M3000
M4000 M5000 M8000 M9000

 

Hardware

IssueStatusDocumentsCR/SRResolution Updated
Power Cord Retaining Clip on M4000 and M5000 Loose Resolved 1019255.1   Work Around: Tie Wrap or Velcro the Clip in place so the cord will not pull out.
Good Clip  Bad Clip Workaround Clip
05/21/2008
M8000 and M9000 PSUBP connector shoulder screws should be inspected upon PSU failure Resolved 1018989.1 <SunBug 6588111> See FAB 1018989.1 02/12/2008
Customers complain about fans being too noisy in M4000 / M5000 systems. Resolved     See document 1339901.1 for Noisy Fan Troubleshooting information. 01/05/2009
Dual Redundancy Power ( DPF ) wired incorrectly. Resolved     DPF fix documentation
OPS augmented processes to test both grids
01/05/2009
M4000 Input Wiring is incorrect Resolved in the factory by additional testing. Collaborate if found on a new system.     M4000 Input Wiring Fix 02/03/2009
M8000 and M9000 fan trays come loose and down platform Resolved 1019704.1 <SunBug 6716245> XCP includes software fix which mitigates the loss of a fan tray. Sun Alert internal section is revised with available field retaining arm retrofit kit. 09/17/2009

 


XCP Issue

IssueStatusDocumentsCR/SRResolutionUpdated
showstatus indicates no failure, but Check LED(on OPNL) is turned on. Fixed in XCP1070   <SunBug 6649341>    -
Front panel LED still shows amber light after clear all faulty components. Closed as dupe of 6645828 "Could not write FRU-ID status" is detected   <SunBug 6651370>    -
"Could not write FRU-ID status" is detected Fixed in xcp 1071 None <SunBug 6645828>   04/20/2008
           

 


IO Issue

IssueStatusDocumentsCR/SRResolutionUpdated
IOU SAS WWID becoming unprogrammed Closed / Will not fix                 <SunBug 6698399>

Workaround - Powercycle the affected IOU twice.

06/03/08

 


DR Issue

IssueStatusDocumentsCR/SRResolutionUpdated
Deleteboard / moveboard - delete_memory thread is hanging on kphysm_del_cleanup during dr testing. Fix Delivered - Fixed in S10_u6 / snv_87 1019090.1      <SunBug 6614737> The DR deleteboard or moveboard operations might hang if either of the following condition exists:
- A DIMM on the target board has disabled memory and the board being
DR'ed has permanent memory assigned to it.
- The system board that is being deleted via DR has
permanent memory and the memory are being migrated
to a system board with smaller amount of memory installed.
Workaround: Don't use DR in the above situation.
02/25/2008

References

@ <BUG:6588111> - 8-642204748 - FLAG IMPORTED/LINKED DATA WITH COLORED TICKMARKS RATHER THAN COLOR
@ <BUG:6645828> - R12 BL :TRACKING BUG FOR ONLINE SELF SERVICE W4 CHANGES
@ <BUG:6649341> - IH6QDV: CONSTRAINT1 VALUE COULD NOT BE RETREIVED IN EXISTING LOOKUPPROFILEOPTION
@ <BUG:6651370> - 7.8.2.5 19227 SEA QF6504 SEBL_ARU
@ <BUG:6698399> - IOU SAS WWID BECOMING UNPROGRAMMED
@ <BUG:6716245> - IBM DB2 TABLE ALIAS' (VIEWS OF A TABLE(S) ) DOESN'T WORK IN IR 9.3.0.1
<NOTE:1002631.1> - Sun SPARC[TM] Enterprise M3000, M4000, M5000, M8000, M9000 XSCF Control Package (XCP) Firmware Image Software Version Matrix Information
<BUG:6614737> - DELETE_MEMORY THREAD IS HANGING ON KPHYSM_DEL_CLEANUP DURING DR TESTING
<NOTE:1018989.1> - M8000 and M9000 PSUBP connector shoulder screws should be inspected upon PSU failure.
<NOTE:1019090.1> - Solaris 10 Under Certain Conditions, Dynamic Reconfiguration (DR) "deleteboard" and "moveboard" Operations May Hang on a SPARC Enterprise M4000/M5000/M8000/M9000
<NOTE:1019255.1> - Sun SPARC Enterprise M4000/M5000 Power Cord Clips not fully engaging
<NOTE:1019704.1> - Sun SPARC Enterprise M8000 and M9000 Servers With Certain Firmware May Experience Unexpected Platform Outage
@<NOTE:1315765.1> - Sun SPARC(R) Enterprise M3000/M4000/M5000/M8000/M9000 (OPL) Servers: Current Issues Page
<NOTE:1339901.1> - Sun SPARC[TM] Enterprise M3000, M4000, M5000, M8000, M9000: Troubleshooting a Noisy FAN on OPL Servers

Attachments
This solution has no attachment
  Copyright © 2012 Sun Microsystems, Inc.  All rights reserved.
 Feedback