Asset ID: |
1-79-1368688.1 |
Update Date: | 2012-07-17 |
Keywords: | |
Solution Type
Predictive Self-Healing Sure
Solution
1368688.1
:
Sun SPARC(R) Enterprise M3000/M4000/M5000/M8000/M9000 (OPL) Servers: Archived Issues Page
Related Items |
- Sun SPARC Enterprise M9000-64 Server
- Sun SPARC Enterprise M9000-32 Server
- Sun SPARC Enterprise M8000 Server
- Sun SPARC Enterprise M3000 Server
- Sun SPARC Enterprise M5000 Server
- Sun SPARC Enterprise M4000 Server
|
Related Categories |
- PLA-Support>Sun Systems>SPARC>Enterprise>SN-SPARC: Mx000
- .Old GCS Categories>Sun Microsystems>Servers>OPL Servers
|
In this Document
Oracle Confidential (PARTNER). Do not distribute to customers.
Reason: Internal Only Information
Applies to:
Sun SPARC Enterprise M3000 Server - Version Not Applicable and later
Sun SPARC Enterprise M5000 Server - Version Not Applicable and later
Sun SPARC Enterprise M8000 Server - Version Not Applicable and later
Sun SPARC Enterprise M9000-32 Server - Version Not Applicable and later
Sun SPARC Enterprise M9000-64 Server - Version Not Applicable and later
Information in this document applies to any platform.
Purpose
This document provides a listing of archived issue known to affect the OPL platform.
Current and Active issues are at 1315765.1
Also check the XCP release notes for known issues.
Details
Hardware
Issue | Status | Documents | CR/SR | Resolution | Updated |
Power Cord Retaining Clip on M4000 and M5000 Loose |
Resolved |
1019255.1 |
|
Work Around: Tie Wrap or Velcro the Clip in place so the cord will not pull out.
Good Clip Bad Clip Workaround Clip |
05/21/2008 |
M8000 and M9000 PSUBP connector shoulder screws should be inspected upon PSU failure |
Resolved |
1018989.1 |
<SunBug 6588111> |
See FAB 1018989.1 |
02/12/2008 |
Customers complain about fans being too noisy in M4000 / M5000 systems. |
Resolved |
|
|
See document 1339901.1 for Noisy Fan Troubleshooting information. |
01/05/2009 |
Dual Redundancy Power ( DPF ) wired incorrectly. |
Resolved |
|
|
DPF fix documentation
OPS augmented processes to test both grids |
01/05/2009 |
M4000 Input Wiring is incorrect |
Resolved in the factory by additional testing. Collaborate if found on a new system. |
|
|
M4000 Input Wiring Fix |
02/03/2009 |
M8000 and M9000 fan trays come loose and down platform |
Resolved |
1019704.1 |
<SunBug 6716245> |
XCP includes software fix which mitigates the loss of a fan tray. Sun Alert internal section is revised with available field retaining arm retrofit kit. |
09/17/2009 |
XCP Issue
Issue | Status | Documents | CR/SR | Resolution | Updated |
showstatus indicates no failure, but Check LED(on OPNL) is turned on. |
Fixed in XCP1070 |
|
<SunBug 6649341> |
|
- |
Front panel LED still shows amber light after clear all faulty components. |
Closed as dupe of 6645828 "Could not write FRU-ID status" is detected |
|
<SunBug 6651370> |
|
- |
"Could not write FRU-ID status" is detected |
Fixed in xcp 1071 |
None |
<SunBug 6645828> |
|
04/20/2008 |
|
|
|
|
|
|
IO Issue
Issue | Status | Documents | CR/SR | Resolution | Updated |
IOU SAS WWID becoming unprogrammed |
Closed / Will not fix |
|
<SunBug 6698399> |
Workaround - Powercycle the affected IOU twice.
|
06/03/08 |
DR Issue
Issue | Status | Documents | CR/SR | Resolution | Updated |
Deleteboard / moveboard - delete_memory thread is hanging on kphysm_del_cleanup during dr testing. |
Fix Delivered - Fixed in S10_u6 / snv_87 |
1019090.1 |
<SunBug 6614737> |
The DR deleteboard or moveboard operations might hang if either of the following condition exists:
- A DIMM on the target board has disabled memory and the board being
DR'ed has permanent memory assigned to it.
- The system board that is being deleted via DR has
permanent memory and the memory are being migrated
to a system board with smaller amount of memory installed.
Workaround: Don't use DR in the above situation. |
02/25/2008 |
References
@ <BUG:6588111> - 8-642204748 - FLAG IMPORTED/LINKED DATA WITH COLORED TICKMARKS RATHER THAN COLOR
@ <BUG:6645828> - R12 BL :TRACKING BUG FOR ONLINE SELF SERVICE W4 CHANGES
@ <BUG:6649341> - IH6QDV: CONSTRAINT1 VALUE COULD NOT BE RETREIVED IN EXISTING LOOKUPPROFILEOPTION
@ <BUG:6651370> - 7.8.2.5 19227 SEA QF6504 SEBL_ARU
@ <BUG:6698399> - IOU SAS WWID BECOMING UNPROGRAMMED
@ <BUG:6716245> - IBM DB2 TABLE ALIAS' (VIEWS OF A TABLE(S) ) DOESN'T WORK IN IR 9.3.0.1
<NOTE:1002631.1> - Sun SPARC[TM] Enterprise M3000, M4000, M5000, M8000, M9000 XSCF Control Package (XCP) Firmware Image Software Version Matrix Information
<BUG:6614737> - DELETE_MEMORY THREAD IS HANGING ON KPHYSM_DEL_CLEANUP DURING DR TESTING
<NOTE:1018989.1> - M8000 and M9000 PSUBP connector shoulder screws should be inspected upon PSU failure.
<NOTE:1019090.1> - Solaris 10 Under Certain Conditions, Dynamic Reconfiguration (DR) "deleteboard" and "moveboard" Operations May Hang on a SPARC Enterprise M4000/M5000/M8000/M9000
<NOTE:1019255.1> - Sun SPARC Enterprise M4000/M5000 Power Cord Clips not fully engaging
<NOTE:1019704.1> - Sun SPARC Enterprise M8000 and M9000 Servers With Certain Firmware May Experience Unexpected Platform Outage
@<NOTE:1315765.1> - Sun SPARC(R) Enterprise M3000/M4000/M5000/M8000/M9000 (OPL) Servers: Current Issues Page
<NOTE:1339901.1> - Sun SPARC[TM] Enterprise M3000, M4000, M5000, M8000, M9000: Troubleshooting a Noisy FAN on OPL Servers
Attachments
This solution has no attachment