Sun Fire X4800 Server Firmware 1.0
This release includes the following firmware:
Released version:
- ILOM version 3.0.9.11 (build number 55414) (Service Processor
firmware) - ILOM 3.0.9.11 for Sun Fire X4800 Management Module (CMM)
- BIOS 23
- CPLD 7.6 and 5.6
- HPC FPGA 1.8
- Hostmon 1.2.1
- SIA 2.4.3.17
- SunVTS 7.0ps08
Sun Fire X4800 Server Firmware 1.0.1
This release includes the following firmware:
Released version:
- ILOM version 3.0.9.30 (build number 57897) (Service Processor
firmware) - ILOM 3.0.9.30 for Sun Fire X4800 Management Module (CMM)
- BIOS 34
- CPLD 7.8 and 5.8
- HPC FPGA 1.8
- PC-CHECK 6.26-s
- Hostmon 1.2.4
- NEM FPGA v15
- SIA 2.4.3.24
- SunVTS 7.0ps08
- MegaRaid (SGX-SAS6-R-REM-Z) SAS MR9262-8i FW 2.50.03-0807/BIOS 3.11.00
- Bugs fixed:
- SunBug 6949570 - spdiag voltest failed in RQT
- SunBug 6969656 - memstore value is NOT restored after reset SP
- SunBug 6973633 - g5cpldflash.sh can brick CMOD if CPLD flash fails.
- SunBug 6934927 - callisto/G5: disable LLEM by default
- SunBug 6962835 - SP version 3.0.9.30 still showing version 3.0.9.11 in CLI and web GUI
- SunBug 6962871 - FRU data has changed a lot after SP flashed to build 2010-24
- SunBug 6895423- allow multiple host serial 'start /SP/console' sessions at same time
- SunBug 6933511 - Pre-RQT unit had a /SYS/FM0 fault.chassis.device.fan.fail Fault Failure
- SunBug 6969930 - CMOD stuck at u-boot flashing ILOM image in a loop
- SunBug 6967076 - Single-sign-on is broken for JavaRConsole
- SunBug 6967397 - JARs need to be re-signed for SW 1.0.1
- SunBug 6937618 - implement the console history feature
- SunBug 6936784 - BM /persist full cause DIMM FRUID not showing up
- SunBug 6969213 - /SYS/SERVICE led is not turned On when /SYS/T_AMB > threshold
- SunBug 6958788 - False fan missing faults reported once flash SP to build 2010-22
- SunBug 6960852 - Fault restoration is unable to set BM service LED.
- SunBug 6916613 - PSU power loss fault is not cleared when power cable is reconnected
- SunBug 6938562 - BL SERVICE LED is not turned off when flash SP while /SYS/SERVICE LED is off
- SunBug 6964477 - Junk code shows in event log "Update inventory starting at node X"
- SunBug 6954474 - PSU ac low line isn't faulted by fault diagnostic.
- SunBug 6959124 - False blade population fault reported on 4-socket after SP flash
- SunBug 6959617 - spare_lane_failover fault policy
- SunBug 6968512 - SP fails to retain DIMM misconfig faults after blade hotplug
- SunBug 6925340 - FMA should not fault processor for parity errors in internal IOH datapaths
- SunBug 6928996 - ILOM missed to report fault on the DIMMs used to replace faulty DIMMs
- SunBug 6931958 - TEMP_FAULT is not On even though /SYS/T_AMB > upper non-recoverable high
- SunBug 6962898 - Thermtrip neither logged nor diagnosed as a fault.
- SunBug 6965686 - Mismatch of CPLD version needs to be faulted.
- SunBug 6955271 - Sometimes failed to start host power
- SunBug 6959130 - P1.B CPLD upgrade has remote I/O error
Sun Fire X4800 Server Firmware 1.1
This release includes the following firmware:
Released version:
- ILOM version 3.0.9.30.a (build number 59127) (Service Processor
firmware) - ILOM 3.0.9.30.a for Sun Fire X4800 Management Module (CMM)
- BIOS 11014100
- CPLD 7.8 and 5.8
- HPC FPGA 1.8
- PC-CHECK 6.26-s
- Hostmon 1.2.6
- NEM FPGA v15
- NEM SAS Expander 5.3.3.4
- OHIA 2.4.3.26
- SunVTS 7.0ps09
- MegaRaid (SGX-SAS6-R-REM-Z) SAS MR9262-8i FW 2.50.03-0807/BIOS 3.11.00
- Bugs fixed:
- SunBug 6974345 - Slot ID in SMBIOS Type 9 structures need to start at 0x1
- SunBug 6973310 - fmtopo should enumerate DIMM and label them on per blade basis.
- SunBug 6972281 - SPMI has wrong bit width
- SunBug 6975306 - _CSD (C-State Dependencies) and _TSD (T-State
Dependencies) return only 0
- SunBug 6960024 - SLES11SP1 has problem to enter C3
- SunBug 6979140 - G5:NEM hangs midplane i2c bus (One of the G5's has ipmitool fru list not showing the Ethernet NICs
- SunBug 6783587 - Libra blades must provide memory ACPI objects
- SunBug 6980326 - G5: BIOS should change the default setting of De-emphasis level to -3.5dB
- SunBug 6965286 - g5: linux/xen: report extra cpus for cstate
- SunBug 6935423 - libra: bios report extra cpus in DSDT when HT is disabled or 4 sockets are used
- SunBug 6930631 - G5 with EMs may experience problems due to CR 6669984
- SunBug 6926674 - Disabling "SRIOV and VTD" causes windows installation to hang
- SunBug 6921159 - libra: EL 5.4: IB PEM does not work with 2S system
- SunBug 6911271 - system loses memory on some CPU branches after a reboot (reboot due to fault injection)
- SunBug 6985583 - G5: setting boot device to default hard drive does not put entry in SEL
- SunBug 6985034 - g5: OEL: Niantic PEMs no driver
- SunBug 6984316 - g5: RH v7 cpuscaling failed on the new kernel.
- SunBug 6982995 - g5: clocktest fail
- SunBug 6980329 - G5: BIOS should enable the 'Extended Synch' in all IOHs
- SunBug 6904623 - Blue LED follows drive after "Prepare Removal" on slot
- SunBug 6895659 - Niwot:MSM:Gui hung for excessive period of time after cable pull of 4 JBOD cascade config
- SunBug 6894955 - EL 5.4 pciehp not work with Metis-E (Emulex/82571 dual port)
- SunBug 6881733 - G5 Slot-Based MAC Address for onboard NICs
- SunBug 6881005 - libra: EL 5.4 non xen kernel crash with 1T memory
- SunBug 6879007 - G5(BQA):Cannot load RHEL5.3 if ACPI is disabled in the BIOS setup
Sun Fire X4800 Server Firmware 1.2 This release includes the following firmware:
Released version:
- ILOM version 3.0.14.17 (build number 62928) (Service Processor
firmware) - ILOM 3.0.14.17 for Sun Fire X4800 Management Module (CMM)
- BIOS 11015600
- CPLD 7.8 and 5.8
- HPC FPGA 1.8
- PC-CHECK 6.26-s
- Hostmon 1.2.6
- NEM FPGA v16
- NEM SAS Expander 5.7.0.0 (requires separate manual update, and must update ILOM/BIOS first)
- SunVTS 7.0ps09
- PSU Firmware: -06 (requires separate manual sunservice access to update)
- Bugs fixed BIOS:
- SunBug 7021571 - G5: ITP CE fault injection does not fault and disable dimm
- SunBug 7014651 - ITP CE fault injection does not generate UE after more than 240 CEs injected within 72hrs
- SunBug 7014414 - ITP injected UE doesn't disable DIMMs
- SunBug 7017811 - 8S configuration should not check for CMOS setup option for "Hemisphere Mode"
- SunBug 7005012 - Bios 52 does not handle DIMM SPD errors correctly
- SunBug 6957529 - Write protect SPD data on Samsung DIMMs
- SunBug 7003872 - 6 core 4 socket system had a CPU error
- SunBug 7009901 - G5 sw 1.2 bl and cpu faulted on 4 socket systems
- SunBug 7007477 - bios: ACPI methods incorrectly use mutex
- SunBug 6957008 - G5 P2 unit had a Memory: BIOS: Configuration Error: MRC Branch error 0x08 in IST/SFT
- SunBug 6974623 - MRC should issue SMBus Stop symbol before 1st transaction
- SunBug 7003685 - G5 has wrong interleave settings in BIOS menu
- SunBug 6992300 - Wrong taps for the longest diagonal links
- SunBug 6959120 - enable patrol scrubbing in G5
- SunBug 6974657 - Increase in memory latency when Patrol scrubbing is enabled
- SunBug 7003871 - Need to update dram_ecc_per_rank_2 msg in SUNECC_HAndler_FAR (SMI handler)
- SunBug 6981008 - ECCs are polled at a slower rate than what's displayed in the setup was missed.
- SunBug 6999563 - Cstate _CSD should have domain id per core.
- SunBug 6999911 - linux need SRAT table consistent with MADT
- SunBug 6992392 - acpi error: method parse execution failed and namespace lookup failure,
- SunBug 6988721 - Modified 'Coordination type' to HW_ALL in Package of _CSD Method
- SunBug 6997918 - Add WHEA missed operations
- SunBug 6999781 - RHEL 6.0 reports AER with Erie PEM
- SunBug 6997677 - g5: smbios reports wrong KCS Base Address
- SunBug 6995077 - SMBIOS records show incomplete brand name for some fields
- SunBug 6993859 - G5M2 BIOS: need to disabled USB controller pci function
- SunBug 6980775 - BIOS should not mask bit 22 "errtimeout' in Bbox error log message
- SunBug 6990388 - Incorrect Message format for "MCA Register dump"
- SunBug 6980774 - Mbox error scraping doesn't report UEs detected by Patrol Scrubber
- SunBug 6981008 - ECCs are polled at a slower rate than what's displayed in the setup
- SunBug 6980776 - Implement "Early uncore reporting", leveraged code from Callisto CR#6963668
- SunBug 6954112 - RHEL 6 Beta reports disabling IRQ 16
- SunBug 6967828 - 2.6.32.y based RHEL6/SLES11SP1: report ACPI error
- SunBug 6956632 - APEI table is invalid
- SunBug 6993326 - G5: RHEL 6.0 beta shows a lot of AER errors with Niwot in 'dmesg'
- SunBug 6889870 - Need to remove some unused ASL code in DSDT of legacy ACPI hotplug
- SunBug 6976081 - BIOS PIRQ table has wrong slot information
- SunBug 6989075 - Need to remove some unused ASL hotplug code in ACPI DSDT
- SunBug 6981424 - Update Serial Redirection eModule to Label: .00.03_SREDIR_03.01_B10
- SunBug 6981422 - Add Poison Forwarding Mode option in Expert Mode of BIOS setup menu
- SunBug 6985175 - Setup menu option "Event Log Configuration" should be removed
- SunBug 6986732 - Setup cleanup
- SunBug 6985109 - Updated, P2 bios/menus Some entries are still changeable with User
- SunBug 6985104 - MAC addresses displayed in BIOS setup and in SP do not match
- SunBug 6973310 - fmtopo should enumerate DIMM and label them on per blade basis
- SunBug 6983163 - Create SMBIOS on board device extended information type
- SunBug 6987258 - Create SMBIOS type 144 (Extended Memory Array)
- SunBug 6993898 - Modified SMBIOS Type 9, 19 and 41
- SunBug 6985905 - Reduce duplicated "No bootable media" logs
- SunBug 6990381 - BIOS is confusing core and uncore MCA banks in MCA dump IPMI messages
- SunBug 6907768 - There is no SEL entry for disabled QPI links
- SunBug 6943821 - Disable USB PCI function
- SunBug 6985083 - Manipulating USB functionality caused various strange results with keyboard
- Bugs fixed in ILOM:
- SunBug 6998390 - G5: spdiag rtc Set Date and Time in 12 hour mode has not yet implemented
- SunBug 6989711 - hostdiags info hangs with Ilom 59127, Out of Memory : Killed process 14215 (dbgLevelUpdater)
- SunBug 6968830 - G5 not keeping the saved value for /SP/services/snmp engineid after SP reset
- SunBug 6993343 - G5: Pc-Check refused to run with error: This program is only for use with Sun Microsystems hardware.
- SunBug 6994649 - G5: Extra property system_identifier under /SYS/BLx
- SunBug 6986590 - G5: No fault when inserting PSU and no AC power after booting up with 2 PSU
- SunBug 6989655 - G5: SP not responsive after idling overnight: dynafrud memory leak.
- SunBug 7015717 - G5/G5+: chassis midplane defaults to C4.
- SunBug 6979293 - G5: Clean up FMOD support in ILOM
- SunBug 6986860 - G5: Error reading sensor PWRBS (#06) using ipmitool kcs interface
- SunBug 6999809 - G5: FRUID is not updated when dimm_ue, ioh, power supply etc. faults are reported
- SunBug 7005646 - g5: 110 volt ac connected to psu does not throw fault
- SunBug 6990850 - G5: does not have /conf/progparts.version on CMOD
- SunBug 6990851 - G5: individual CMOD has upload firmware option in webgui
- SunBug 6996269 - G5: Need to disable Ozone features and clean up other new power management features
- SunBug 6931837 - G5: System Allocated Power is way much higher than the sum of Component Allocated Power
- SunBug 6990799 - G5: kernel: Watchdog timer about to expire!
- SunBug 6981303 - g5 REM FRU type is incorrect
- SunBug 6982755 - g5: ipmitool shows hidden sensors SYS/T_AMB1 SYS/T_AMB2
- SunBug 6991365 - SP hostname missing PSN
- SunBug 6991369 - G5-NEM: Unsupported prepare_to_remove feature appears under NEM properties
- SunBug 6999104 - G5: NEM STATE turns Power Off instead of Degraded when faulted
- SunBug 7000145 - Flash updates failing and asking to retry a lot
- SunBug 6983353 - G5: New 2.26.27 kernel for G5 SP and G5 BM.
- SunBug 6983355 - G5: enable IPv6
- SunBug 6983308 - G5: Bad HidStartRedirection reported by SQA
- SunBug 6984331 - G5: ipmiflash takes 2 hours on kcs and 15 minutes on lanplus
- SunBug 6919378 - G5: fruimage.xml file missing from fruid dataset snapshot: command timeout occurs.
- SunBug 6993955 - G5: Event log "Inventory has been updated starting at node '/SYS' " repeats every 5 minutes
- SunBug 6993961 - G5: /var/log/messages keep showing dynafru_write_install ERRORs
- SunBug 6995465 - G5: REM fru disappears after SP reset
- SunBug 7001552 - G5: Reset SP from CLI or WebGUI resets the hosts too, G5 Platform with Ilom r59576
- SunBug 6882970 - 15sec_average of /SYS/VPS/history/ no data
- SunBug 6915976 - G5: SP event log shows duplicate messages and ID sequence is out of order
- SunBug 7014414 - ITP injected UE doesn't disable DIMMs
- SunBug 6897878 - G5 SP intermittent Error: ipmitool ... sdr list Unable to establish LAN session
- SunBug 6990950 - G5: flash intermittently hanging
- SunBug 7006108 - g5: ipmiflash downgrade fails 3.0.14.17 to 3.0.9.30.a
- SunBug 7006803 - G5/G5+: remove LLEM.
- SunBug 7007753 - G5: reset /SP only reboots the CMOD0 SP, not CMOD1-2-3 SP.
- SunBug 6899941 - G5 C4: fpgautil doesn't work for C4 NEM
- SunBug 6897016 - segfault in libfrucapi
- SunBug 6839231 - G5/C4: libfru support of 64bit SAS World-Wide Name
- SunBug 6919012 - G5: NEM short FRU's New_Serial_Number doesn't show up for NEMs.
- SunBug 6880055 - G5: CMM ECB failed I2C probe test
- SunBug 6895388 - G5: Estimated upgrade time 6 minutes is too short for G5+BMs upgrade
- SunBug 6997277 - Remove gemini/pegasus, wolf/hercules, G4 and Thor from trunk
- SunBug 6879428 - KVMS: Redirection failure message does not tell the reason
- SunBug 6908018 - ipmitool randomly receives error: Unable to establish IPMI v2 / RMCP+ session
- SunBug 6882624 - RKVMS: Video Redirection fails with "Server is not ready to read" then login pop-up menu appears
- SunBug 6859522 - G5-SP/C4-NEM: there needs to be UI using which users can upgrade NEM firmware from G5-SP
- SunBug 7013078 - IPV6 Settings in GUI allows invalid combinations of user selectable options
- SunBug 6766579 - C4: frutool/libfru enhancement for various new SEEPROMs in C4 (Diskbackplane, fan board, etc)
- SunBug 6882770 - G5: /SYS/DBP/PRSNT appears in CLI & webGUI while it's not in xml & ipmi
- SunBug 6883305 - Display NEM and storage blade long FRUID content in CMM
- SunBug 6898302 - G5: No PSU fault diagnosed when a PSU is hot removed
- SunBug 6888496 - G5: SP does not clear fault when faulted PSU has been pulled out
- SunBug 6864917 - G5-NEM: CMM does not show NEM fault
- SunBug 6898602 - G5: KCS ipmitool commands from host do not seem to forward from BM to SP
- SunBug 6905631 - G5: faultmgmt shell missing fmadm, fmdump commands
- SunBug 6871182 - C10CMM: Add dynamic FRUID support
- SunBug 6874420 - G5: No fru info shows up on G5
- SunBug 6891203 - fdd: No fault/clear/repair events when using fdd with plathwsvcd
- SunBug 6865659 - G5: Forward IPMI messages from BM to SP
- SunBug 6878801 - G5 ILOM: HDD targets showing up in /SYS/BL/REM
- SunBug 6879378 - G5/C4: several issues related to /SYS/T_AMB: set command, etc...
- SunBug 6879392 - G5: G5 NEM should not have cli object
- SunBug 6896143 - G5: Add temperature history
- SunBug 6862934 - G5-SP: hostpower script should be able to get/set host power state from SP
- SunBug 6859483 - G5: need to show in G5-SP's CLI/BUI, G5-BM's ILOM version and that of the image in G5-SP's flash
- SunBug 6876255 - G5: G5 Web GUI missing Host Control tab for boot device setting
- SunBug 7011402 - G5/G5+: trunk BM network configuration broken.
- SunBug 6854089 - Libra/G5: Revisit SP_HOLD_PWR_OFF_L on blades
- SunBug 6898226 - G5 SP spdiag FAN test flase failed lower spped test
- SunBug 6875319 - G5: /SYS target is missing after reset G5 SP
- SunBug 6926180 - G5: Set /network/switchconf error found in event log when configure network from web GUI
- SunBug 6869441 - G5 SP: SP hangs after about an hour of uptime
- SunBug 6865004 - Libra/G5 BM: start /SP/console stops working.
- SunBug 6904633 - G5: REM FRUID not showing up with latest P1.last
- SunBug 6908621 - G5: /SYS/BLx/Py/Dz/SERVICE LED is not On when Memory ECC Errors and MRC warnings are diagnosed
- SunBug 6903007 - G5: Fix Dynamic fruid to use TLI MAC address
- SunBug 6904036 - G5: Web GUI Configuration -> Network Tab does not show the correct Information
- SunBug 6893138 - G5: CPLD / NEM / PSU FW version doesn't look right from fru data
- SunBug 6911475 - G5: Change cli to display /SYS/EMx.y instead of /SYS/BLn/PEMy
- SunBug 6908999 - G5: NEM power_state is On when its power is off
- SunBug 6883393 - G5: Access Blade FRUIDs from G5 SP.
- SunBug 6904481 - G5: dynafru_cache_identity errors found in /var/log/messages
- SunBug 6902751 - G5: Reverse Support for Chassis MAC Address allocation.
- SunBug 6842044- G5: Support Chassis MAC Address allocation.
- SunBug 6886075 - G5: Processing of BIOS BT OEM error messages for Nehalem EX platforms.
- SunBug 6879073 - G5: fdd coredumps
- SunBug 6968512 - SP fails to retain DIMM misconfig faults after blade hotplug
- SunBug 6897855 - G5: healthd faults are not diagnosed
- SunBug 6906155- G5: need to properly handle *box ereports and poison data-related errors
- SunBug 6906164 - G5: no fault should be diagnosed for FBD_INIT_NO_MEMORY
- SunBug 6874422 - G5: Need uboot diag documentation
- SunBug 6835613 - G5/C4: A239 low-line support 120 vs 220 operation and status
- SunBug 6878102 - G5: After CMM/SP upgrade, fans come on full blast and stay there
- SunBug 6896141 - G5: LLEM, must enable bit 6 to prevent oscillation in G5
- SunBug 6896183 - G5: LLEM, must set threshold bits on PSUs to indicate a 4 PSU system
- SunBug 6844637 - C4: PSU presence sensors report "na"
- SunBug 6849947 - G5-SP: Host serial configuration and Serial Port Sharing
- SunBug 6849948 - G5 SP: /SP/reset functionality
- SunBug 6867026 - G5: SP serial console start option -force not work
- SunBug 6848556 - libc10blade c10 cmm and blades: A231 PSU budget is not detected correctly
- SunBug 6897367 - G5: start /SP/console -script prompts confirmation question
- SunBug 6875819 - G5: On board disk missing intermittently or disk is unconfigurable
- SunBug 6864196 - G5: need to be able to run diagnostic tools PC-Check/spdiga/hostdiag/hostmon on G5-SP
- SunBug 6887040 - g5: GUI doesn't display BIOS information properly when asking for upgrade confirmation
- SunBug 6798838 - TFTP server for firmware download needs to support download SAS2 NEM firmware
- SunBug 6862334 - G5 SP/C4 CMM: Factory needs ethernet switch configuration to active port 0 and disable port 1.
- SunBug 6873624 - G5SP: OOM During Firmware Upgrade
- SunBug 6803945 - G5 CMM: hostdiag and spdiag for multiple G5 blades.
- SunBug 6892360 - pptftpd: Can't handle remote files
- SunBug 6893085 - G5: Some BMs not getting upgraded when flash G5 SP - and not accessible
- SunBug 6888356 - G5: Host is not off during SP upgrade, BIOS not upgraded immediately
- SunBug 6859481 - G5: SP's ILOM image should build and bundle BM's as well
- SunBug 6906071 - G5: BM upgrade stuck
- SunBug 6873876 - NEM fw must be wrapped in a pkg in order for ILOM due to UI constraints
- SunBug 6895377 - G5-NEM: use soft reset instead of hard reset after fw upgrade
- SunBug 6889776 - G5 SP: xferd and frmd take a long time to start
- SunBug 6897863 - G5 BM has service tags - not needed / exposed
- SunBug 6897875 - G5 SP - upgrade via sunservice not resetting when finished
- SunBug 6888730 - G5: usrmgt_upgrade error message shows in BM u-boot console
- SunBug 6819963 - G5 Blade/Libra: Green OK LED behavior not right.
- SunBug 6866630 - G5 SP / Libra : /coredump does not get auto-cleaned when reaches to /close to 100%
- SunBug 6870056 - G5: add Storage Viewer support
- SunBug 6872695 - G5: Missing G5 SP hardware model in Permanent environment
- SunBug 6873611 - G5-Libra: BM tends to lose connection with G5 after resetting G5 SP
- SunBug 6859482 - G5: blades should automatically upgrade themselves with the fw/bios/cpld bundled in SP's ILOM image
- SunBug 6883196 - g5: /conf keeps getting reset
- SunBug 6882889 - g5: turn cpld auto-upgrade feature off
- SunBug 6859257 - Callisto/Libra: i2ctool fails when there is no mux
- SunBug 6848071 - TLI: Need common startup utilities to manage product info
- SunBug 6895605 - G5: setpsnc does not copy mac adress and WWN from fru
- SunBug 6885522 - G5: Chassis MAC address missing leading 0 in "Product Extra"
- SunBug 6904813 - Don't initialize primary container for TLI_FAILURE
- SunBug 6866015 - G5 SP: No space left on device message / Segmentation fault - Coredump with firmware upgrade
- SunBug 6975724 - Failed to set usentpserver value if it's not all small
letters
Sun Fire X4800 Server Firmware 1.2.1
This release includes the following firmware:
Released version:
- ILOM version 3.0.14.17.a (build number 63656) (Service Processor
firmware) - ILOM 3.0.14.17.a for Sun Fire X4800 Management Module (CMM)
- BIOS 11016200
- CPLD 7.8 and 5.8
- HPC FPGA 1.8
- PC-CHECK 6.26-s
- Hostmon 1.2.6
- NEM FPGA v16
- NEM SAS Expander 5.7.0.0 (requires separate manual update, and must update ILOM/BIOS first)
- OHIA 2.5.3.18
- SunVTS 7.0ps09
- MegaRaid (SGX-SAS6-R-REM-Z) SAS MR9262-8i FW 2.120.33-1197/BIOS 3.21.00_4.11.05.00_0x05000000
- LSI SAS-2 HBA (SGX-SAS6-EM-Z) SAS FW 05.00.29.00/BIOS 07.05.09.00
- PSU Firmware: -06 (requires separate manual sunservice access to update)
- Bugs fixed ILOM:
- 7013022 - g5 ipmi msg IP Address for OEM Command. Net Function: 0x2E (Command: 0x3E) IPAddr: 127.0.0.1
- Bugs fixed BIOS:
- 7029195 - Implement a retry mechanism for unexplained DDR training failures
Sun Fire X4800 Server Firmware 1.3
This distribution offers the software and firmware supporting Sun Fire
X4800 servers. The Tools and Drivers platform contains the Tools and
Drivers CD ISO image as well as common and operating system-specific
files and drivers. The Firmware platform contains LSIUtil Maintenance
Utility, BIOS 11016600, Integrated Lights Out Manager (ILOM) firmware
3.0.14.17a, SAS Expander Firmware 5.7.0.0, Oracle Hardware Installation
Assistant 2.5.3.11, Linux Mega CLI and Linux MSM.
Installation instructions for the software and firmware are available in
the product User's Guide. See the Product Notes for the latest product
updates.
The firmware package ILOM-3_0_14_17_b_r64840-Sun_Fire_X4800.pkg contains:
Released version:
- ILOM version 3.0.14.17.b (build number 64840) (Service Processor
firmware) - ILOM 3.0.14.17.a for Sun Fire X4800 Management Module (CMM)
- BIOS 11016600
- CPLD 7.8 and 5.8
- HPC FPGA 1.8
- PC-CHECK 6.26-s
- Hostmon 1.2.6
- NEM FPGA v17 (does not requires AC power cycle after update)
- NEM SAS Expander 5.7.0.0 manufacture image 0104 (requires separate manual update, and must update ILOM/BIOS first)
- OHIA 2.5.3.11
- SunVTS 7.0ps09
- MegaRaid (SGX-SAS6-R-REM-Z) SAS MR9262-8i FW 2.120.33-1197/BIOS 3.21.00_4.11.05.00_0x05000000
- LSI SAS-2 HBA (SGX-SAS6-EM-Z) SAS FW 05.00.29.00/BIOS 07.05.09.00
- PSU Firmware: -06 (requires separate manual sunservice access to update)
- Bugs fixed ILOM:
- SunBug 6537282 - Firmware Update docs do not cite which order to do upgrade - LSI first or BIOS/SP
- SunBug 6881237 - Prove Physical Presence button - no explanation in documentation as to what this is.
- SunBug 6979140 - X4800:NEM hangs midplane i2c bus (One of the X4800's has ipmitool fru list not showing the Ethernet NICs.)
- SunBug 6935471 - X4800: document X4800's ethernet management port usage
- SunBug 6906176 - X4800: Power Button pressed event is logged when run start/stop /SYS from CLI
- SunBug 6915976 - X4800: SP event log shows duplicate messages and ID sequence is out of order
- SunBug 6917474 - X4800: Config restore failed for Unable to restore property '/SP/serial/host(external)/commitpending'
- SunBug 7047462 - G5/G5+: NEM FPGA/GB PHY PRIOM script needed
- SunBug 6968830 - X4800 not keeping the saved value for /SP/services/snmp engineid after SP reset
- SunBug 6986590 - No fault when inserting PSU and no AC power after booting up with 2 PSU
- SunBug 6979293 - Clean up FMOD support in ILOM
- SunBug 6986860 - Error reading sensor PWRBS (#06) using ipmitool kcs interface
- SunBug 7014414 - ITP injected UE doesn't disable DIMMs
- SunBug 6999809 - FRUID is not updated when dimm_ue, ioh, power supply etc. faults are reported
- SunBug 7005646 - 110 volt ac connected to psu does not throw fault
- SunBug 7008088 - Identify mismatch of CMOD/CPU in the system
- SunBug 6963650 - Fault Management needs to Fault DIMM with MRC DIMM SPD Checksum error reported by BIOS
- SunBug 6990851 - individual CMOD has upload firmware option in webgui
- SunBug 6996269 - Need to disable Ozone features and clean up other new power management features
- SunBug 6931837 - System Allocated Power is way much higher than the sum of Component Allocated Power
- SunBug 6990799 - kernel: Watchdog timer about to expire!
- SunBug 6897878 - SP intermittent Error: ipmitool ... sdr list Unable to establish LAN session
- SunBug 6984054 - Stop /SYS showed failed to stop /SYS message even when it worked
- SunBug 6981303 - REM FRU type is incorrect
- SunBug 7008855 - X4800: set /SP/cli timeout=0 to match the default on other ILOM products
- SunBug 6982755 - ipmitool shows hidden sensors SYS/T_AMB1 SYS/T_AMB2 DBP/HDD*/STATE
- SunBug 6990950 - flash intermittently hanging
- SunBug 6991363 - Hostname changed after SP flash with preserve config option
- SunBug 6991365 - SP hostname missing PSN
- SunBug 6991369 - X4800-NEM: Unsupported prepare_to_remove feature appears under NEM properties
- SunBug 6987272 - g5cpldflash.sh needs to move from escalation mode to service mode
- SunBug 6983355 - X4800: enable IPv6
- SunBug 6940990 - MRC branch fatal error doesn't fault a FRU due to failover warning
- SunBug 6993911 - /SYS Properties missing product_swoRDFish_id
- SunBug 6983308 - Bad HidStartRedirection reported by SQA
- SunBug 6969473 - X4800 start /SP/console isn't functional when used with ldap user
- SunBug 6984331 - ipmiflash takes 2 hours on kcs and 15 minutes on lanplus
- SunBug 6927468 - Change Option ROM exhausted message in the ILOM log to include Bus#/Device#/Function#
- SunBug 6919378 - fruimage.xml file missing from fruid dataset snapshot: command timeout occurs.
- SunBug 7006803 - X4800: remove LLEM.
- SunBug 7007753 - X4800: reset /SP only reboots the CMOD0 SP, not CMOD1-2-3 SP.
- SunBug 6995465 - X4800: REM fru disappears after SP reset
- SunBug 7006418 - prtfru for /SYS/BL* and /SYS/BL0/REM don't show up correctly
- SunBug 7001552 - Reset SP from CLI or WebGUI resets the hosts too, X4800 Platform with Ilom r59576
- SunBug 6882970 - 15sec_average of /SYS/VPS/history/ no data
- SunBug 7006567 - fan fault shows /SYS/FMx/ERR has some incorrect values
- SunBug 6959571 - Improve DRAM CE fault diagnosis granularity to a single DIMM
- SunBug 6959576 - Callisto: Use uncore box error messages for procesor fault diagnosis
- SunBug 7000421 - disable LLEM in PS0 when enabling LLEM in PS1
- Bugs fixed BIOS:
- SunBug 7003993 - CZDAP: PTO T5140 Some PTO parts not appearing in Line Items in Oracle flow
- SunBug 6950414 - X4800 system can't be powered up by I2C during DC cycling
- SunBug 6946921 - [WATCH] RQT failure on 4GB Samsung/Hynix DIMM - SPD corruption
- SunBug 6959120 - Enable patrol scrubbing in X4800
- SunBug 6981008 - ECCs are polled at a slower rate than what's displayed in the setup
- SunBug 7026045 - BIOS needs to disable ASPM in ACPI RSDT & XSDT tables
- SunBug 7003634 - BIOS needs to allocate big resource for empty hotplug slots
- SunBug 7010729 - Some of thermal related registers of IOH are not set correctly
- SunBug 6889870 - G5: Need to remove some unused ASL code
- SunBug 6954081 - G5: Update Nhm-EX microcode (for SPECweb2009 QoS failure)
- SunBug 7037930 - G5: Retry BIOS (11016200) does not operate correctly in MRC serial mode
- SunBug 7017810 - Disable Viral mode in G5
- SunBug 7022305 - G5: 6 socket configuration shows fault.cpu.intel.quickpath.interconnect
|