Asset ID: |
1-79-1363084.1 |
Update Date: | 2011-10-07 |
Keywords: | |
Solution Type
Predictive Self-Healing Sure
Solution
1363084.1
:
Sun Fire X4470 M2 Specifications Page
Related Categories |
- PLA-Support>Sun Systems>x64>Server>SN-x64: SERVER 64bit
- .Old GCS Categories>Sun Microsystems>Servers>x64 Servers
|
In this Document
Purpose
Sun Fire X4470 M2 Specifications Page
References
Oracle Confidential (PARTNER). Do not distribute to customers
Reason: Migration of Panacea Content
Applies to:
Sun Fire X4470 M2 - Version: Not Applicable
and later [Release: N/A and later ]
Information in this document applies to any platform.
Purpose
This document contains the Sun Fire X4470 M2 Specifications Page.
Sun Fire X4470 M2 Specifications Page
Sun Fire X4470 M2 Specifications
The links to Sun Fire X4470 M2 specifications are:
- Electrical
- Input:
- Nominal frequencies 50/60 Hz
- AC operating voltage range 100-127 VAC for 2 CPUs
- 200-240 VAC for 2 or 4 CPUs
- Maximum current AC RMS 12A @ 100 VAC / 12A @ 200 VAC
- Power dissipation:
- Max power consumption 1800 W
- Max heat output 6143 BTU/hr
- Volt-Ampere rating 1837 VA @ 240 VAC, 0.98 P.F.
- Environmental
- Operating temperature (single, non-rack system) 5o C to 35o C (41o F to 95o F)
- Nonoperating temperature (single, non-rack system) -40o C to 70o C (-40o F to 158o F)
- Operating humidity (single, non-rack system) 10% to 90% relative humidity, noncondensing
- Physical
- Height 5.25 inches/133 mm
- Width 17.19 inches/437 mm
- Depth 27.8 inches/706 mm
- Weight 96 lbs/16.36 kg
- Rack Mounting Specs
- Structure - Four-post rack (mounting at both front and rear).
- Two-post racks are not compatible.
- Rack horizontal opening and unit vertical pitch
- Conforms to ANSI/EIA 310-D-1992 or IEC 60927 standards.
- Only M6 tapped or 9.5 mm square are supported.
- Distance between front and rear mounting planes
- Minimum 610 mm and maximum 915 mm (24 inches to 36 inches).
- Clearance depth in front of front mounting plane
- Distance to front cabinet door is at least 25.4 mm (1 inch).
- Clearance depth behind front mounting plane
- Distance to rear cabinet door is at least 900 mm (35.5 inches) with the cable management arm
- Clearance depth behind front mounting plane
- Distance to rear cabinet door is at least 770 mm (30.4inches) without the cable management arm.
- Clearance width between front and rear mounting planes
- Distance between structural supports and cable troughs is at least 456 mm (18 inches).
- Server dimensions
- Depth: (not including PSU handle): 732 mm (28.82 inches)
- Width: (not including ears): 436.5 mm (17.19 inches)
- Height: 129.85 mm (5.11 inches)
- More information at Oracle's website:
References
<NOTE:1330254.1> - X86 Product Home
<NOTE:1362199.1> - Sun Fire X4470 M2 Product Page
<NOTE:1362217.1> - Sun Fire X4470 M2 Patches/Firmware Page
<NOTE:1362675.1> - Sun Fire X4470 M2 Issues Page
<NOTE:1362706.1> - Sun Fire X4470 M2 Training/Knowledge Page
<NOTE:1362710.1> - Sun Fire X4470 M2 Troubleshooting Page
<NOTE:1363084.1> - Sun Fire X4470 M2 Specifications Page
Attachments