| Release Date | Component | Patch Number | 
|---|
| Base Image | Oracle Database Appliance OS Image -- 2.1.0.0.0 | Patch 12999313 | 
| End User Bundle | Oracle Database Appliance End-User Bundle 
 p12978712_21020_Linux-x86-64.zip - 11.2.0.2.5 GI/RDBMS clone file
 | Patch 12978712 | 
| 03-Jan-2012 | ODA 2.1.0.1.0 p13539664_21010_Linux-x86-64.zip
 
 Patch bundle includes
 
 * SAS disk fw update from 0805 to 0A25 and oak rpm updates
 * Support network configuration without DNS and one SCAN ip
 * Support ASR (SNMP) traps for disk
 | Patch 13539664 is Obsolete, Download Patch 2.1.0.2.0
 
 Bug list report here
 | 
|  | ODA 2.1.0.2.0 
 p13565278_21020_Linux-x86-64.zip
 
 Patch bundle includes
 
 * 2.1.0.1.0 fixes
 * oakpatch
 * 11.2.0.2.5 GI PSU5 Patchset update
 | Patch 13565278 
 Bug list report here
 | 
| 29-Feb-2012 | ODA 2.1.0.3.0 
 p13622348_21030_Linux-x86-64.zip
 
 Patch bundle includes
 
 * Contains 2.1.0.1.0, 2.1.0.2.0 fixes
 * Integrate ASR ILOM configuration to complete the ASR manager setup
 * New option to pass the configuration files for deployment:
 #oakcli deploy -conf <config_file>
 * CHM is temporarily disabled as a workaround for bug 13635562
 * End User Bundle 11.2.0.2.5 GI PSU5 (Patchset Update)
 * Upgrade ipmitool from 1.8.10.3 to 1.8.10.4
 * BIOS Fix (CPU Performance Issue) BIOS Fix updates to clear the IA32_CLOCK_MODULATION, which improves the CPU performance drastically.
 * ILOM version updated to 3.0.14.13.a r70764.
 * BIOS version updated to 12010304
 | Patch 13622348 
 Bug list report Here
 | 
| 13-Mar-2012 | ODA 2.1.0.3.1 
 p13817532_21031_Linux-x86-64.zip
 
 This patch addresses the issue where a possible disk failure could trigger a system shutdown.
 
 This patch is not cumulative. You must first install OAK Patch 2.1.0.3.0 and then install 2.1.0.3.1 on top of that.
 | Patch 13817532 
 Bug List report HERE
 | 
| 18-April-2012 | ODA 2.2.0.0.0   
This patch included all previous 2.1.0.1.0, 2.1.0.2.0, 2.1.0.3.0 and 2.1.0.3.1 fixes.This patch will upgrade the existing OEL 5.5 to UEK 5.8.End-User GI/RDBMS clone 11.2.0.3.2 GI PSU2.  This patch can upgrade the existing 11.2.0.2[4,5] to 11.2.0.3.2.CHM is enabled again.   | <Patch: 13858874> Iso Image <Patch: 12999313> Bug List Report HERE | 
| 23-Jul-2012 | ODA 2.3.0.0.0
 p13982331_23000_Linux-x86-64.zip
   
This patch is not cumulative. If you have an OAK 2.1 ODA system, you must first run the "update -patch 2.2.0.0.0 --infra" command, complete the deployment with 2.2.0.0.0 EndUserBundle (GI/RDBMS clone), and then apply OAK patch 2.3.0.0.0 on top of that.Multiple database homes and multiple databases supportCreate new database homes and databasesDelete databases and databasesEnd-User GI/RDBMS 11.2.0.3.3 GI PSU3 clone files.  This patch can patch the existing GI home from 11.2.0.3.2 to 11.2.0.3.3 and patch the existing rdbms from 11.2.0.2[4,5,6] to 11.2.0.2.7 or 11.2.0.3.2 to 11.2.0.3.3 or upgrade the existing 11.2.0.2.x to 11.2.0.3.x.SAS disk fw update from 0A25 to 0B25 and oak rpm updatesHMP version updated to 2.2.4.ILOM version updated to 3.0.16.22 r73911.BIOS version updated to 12010309Odachk is includedDB PSU 11.2.0.2.7 can be downloaded for creating a 11.2.0.2.7 dbhome.  The patch # is 14349293. |  Patch 13982331   Bug list report   HERE | 
| 23-Jul-2012 |   End User GI/RDBMS Clone 2.3.0.0.0   p12978712_23000_Linux-x86-64.zip   
Contains GI + RDBMS version 11.2.0.3.3Use this End User Bundle for your deployment.   | Patch 12978712 | 
| 23-Jul-2012 | 1.2.0.2.7 RDBMS Clone 2.3.0.0.0 p14349293_23000_Linux-x86-64.zip   
Contains RDBMS version 11.2.0.2.7Use this RDBMS Clone file for your 11.2.0.2.7 database home creation.   | Patch 14349293 |