![]() | Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Predictive Self-Healing Sure Solution 1359374.1 : T2 Server PLX Firmware Installation Example
Applies to:Sun SPARC Enterprise T5120 Server - Version: Not ApplicableSun SPARC Enterprise T5220 Server - Version: Not Applicable and later [Release: N/A and later] Sun SPARC Enterprise T5140 Server - Version: Not Applicable and later [Release: N/A and later] Sun SPARC Enterprise T5240 Server - Version: Not Applicable and later [Release: N/A and later] Sun Netra T5220 Server - Version: Not Applicable and later [Release: N/A and later] Information in this document applies to any platform. PurposeThis lists an example of PLX FW installation.T2 Server PLX Firmware Installation ExampleThe PLX firmware is low level firmware which is unaffected by system firmware updates or Solaris OS updates so only needs to be loaded once. To install, transfer the zip file to the system to be updated and unzip. Be sure the system is displayed via 'iostat -En', and also confirm that the DVD drive is a SATA drive:# iostat -En c0t0d0 Soft Errors: 0 Hard Errors: 0 Transport Errors: 0 Vendor: TEAC Product: DV-W28SS-R Revision: 1.0C Serial No: Size: 3.87GB <3869573120 bytes> Media Error: 0 Device Not Ready: 0 No Device: 0 Recoverable: 0 Illegal Request: 0 Predictive Failure Analysis: 0 Next, ensure that the DVD is inactive & all USB devices are removed. Its best to remove any DVD media to ensure its inactive. Note your existing firmware version by executing the update utility with no options: # ./oxfd_update.sparc Oxford Firmware Updater version 0.4 Currently Running 12:37:37 Jul 20 2011 (v 1.00.000e) firmware Update the firmware if this version is prior v1.00.0010, by the following command: # ./oxfd_update.sparc -f v1.00.0010.bin Oxford Firmware Updater version 0.4 Currently Running 15:09:37 Oct 30 2009 (v 1.00.000e) firmware ERROR: from reset device -5 Programming firmware PASSED: Firmware updated from file v1.00.0010.bin Sep 28 11:13:37 ott16cmt unix: WARNING: /pci@0/pci@0/pci@1/pci@0/pci@1/pci@0/usb@0,2/device@2/storage@0/disk@0,0 (sd2): Sep 28 11:13:37 ott16cmt Command failed to complete...Device is gone Sep 28 11:13:37 ott16cmt unix: WARNING: /pci@0/pci@0/pci@1/pci@0/pci@1/pci@0/usb@0,2/device@2/storage@0/disk@0,0 (sd2): Sep 28 11:13:37 ott16cmt Command failed to complete...Device is gone Note that if viewing the console, it is normal to see a number of online messages followed by a number of off line messages as the controller resets itself. Please ignore the device -5 & Device is gone errors. Once the update completes the new version is installed. To verify: # ./oxfd_update.sparc Oxford Firmware Updater version 0.4 Currently Running 12:37:37 Jul 20 2011 (v 1.00.0010) firmware Attachments This solution has no attachment |
||||||||||||
|