Sun Microsystems, Inc.  Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-79-1332666.1
Update Date:2011-12-13
Keywords:

Solution Type  Predictive Self-Healing Sure

Solution  1332666.1 :   Sun Fire[TM] 3800, 48x0, 6800, E2900, E4900, E6900, v1280 or Netra[TM] 1280, or 1290: Firmware Matrix  


Related Items
  • Sun Fire 4810 Server
  •  
  • Sun Fire 3800 Server
  •  
  • Sun Netra 1290 Server
  •  
  • Sun Fire 6800 Server
  •  
  • Sun Fire E6900 Server
  •  
  • Sun Fire E2900 Server
  •  
  • Sun Fire V1280 Server
  •  
  • Sun Fire 4800 Server
  •  
  • Sun Fire E4900 Server
  •  
  • Sun Netra 1280 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>SPARC>Enterprise>SN-SPARC: Exx00
  •  
  • .Old GCS Categories>Sun Microsystems>Servers>Midrange Servers
  •  




In this Document
  Purpose
  Sun Fire[TM] 3800, 48x0, 6800, E2900, E4900, E6900, v1280 or Netra[TM] 1280, or 1290: Firmware Matrix


Applies to:

Sun Netra 1280 Server - Version: Not Applicable and later   [Release: N/A and later ]
Sun Fire 3800 Server - Version: Not Applicable and later    [Release: N/A and later]
Sun Fire 4810 Server - Version: Not Applicable and later    [Release: N/A and later]
Sun Fire 6800 Server - Version: Not Applicable and later    [Release: N/A and later]
Sun Fire E2900 Server - Version: Not Applicable and later    [Release: N/A and later]
Information in this document applies to any platform.

Purpose

This document will provide links to all Firmware versions for Sun Fire Midrange Servers.  5.20.X is the most current major release.  Click Here to download 5.20.17. Scroll down for the other previous patch versions of this major release.

It is strongly suggested that customers install the most up to date firmware. 

See the bottom of this document for Links and information on older Major releases.

Sun Fire[TM] 3800, 48x0, 6800, E2900, E4900, E6900, v1280 or Netra[TM] 1280, or 1290: Firmware Matrix

Firmware
Version
Readme
Status Release Date Bugs Fixed Patch RTOS
Version
Solaris Version DR Support UltraSPARC III UltraSPARC IV UltraSPARC IV+ SunMC Other
5.20.17 Available 30 Jun 2011 1 114527-18 49 S8U7,S9,S10 Yes 1200 / 1050 / 900 / 750 1350 / 1200 / 1050 1500 / 1800 /1950 3.5
S8U6 No 1200 / 1050 / 900 / 750
S8U4, S8U5 750
5.20.16 Available 13 Sep 2010 2 114527-17 49 S8U7,S9,S10 Yes 1200 / 1050 / 900 / 750 1350 / 1200 / 1050 1500 / 1800 /1950 3.5
S8U6 No 1200 / 1050 / 900 / 750
S8U4, S8U5 750
5.20.15 Obsolete 17 Jun 2010 5 114527-16 49 S8U7,S9,S10 Yes 1200 / 1050 / 900 / 750 1350 / 1200 / 1050 1500 / 1800 /1950 3.5
Setchs no longer service mode
S8U6 No 1200 / 1050 / 900 / 750
S8U4, S8U5 750
5.20.14 Obsolete 01 Dec 2009 4 114527-15 49 S8U7,S9,S10 Yes 1200 / 1050 / 900 / 750 1350 / 1200 / 1050 1500 / 1800 /1950 3.5
Fan speed Increased for V1280/E2900
S8U6 No 1200 / 1050 / 900 / 750
S8U4, S8U5 750
5.20.13 Obsolete 02 Jul 2009 3 114527-14 48 S8U7,S9,S10 Yes 1200 / 1050 / 900 / 750 1350 / 1200 / 1050 1500 / 1800 /1950 3.5
S8U6 No 1200 / 1050 / 900 / 750
S8U4, S8U5 750
5.20.12 Obsolete 13 Feb 2009 10 114527-13 48 S8U7,S9,S10 Yes 1200 / 1050 / 900 / 750 1350 / 1200 / 1050 1500 / 1800 /1950 3.5
Many Timezone Updates
S8U6 No 1200 / 1050 / 900 / 750
S8U4, S8U5 750
5.20.11 Obsolete 24 Oct 2008 5 114527-12 48 S8U7,S9,S10 Yes 1200 / 1050 / 900 / 750 1350 / 1200 / 1050 1500 / 1800 /1950 3.5
S8U6 No 1200 / 1050 / 900 / 750
S8U4, S8U5 750
5.20.10 Obsolete 09 Jul 2008 2 114527-11 47 S8U7,S9,S10 Yes 1200 / 1050 / 900 / 750 1350 / 1200 / 1050 1500 / 1800 /1950 3.5
Fix Alert <Document 1019109.1> Sendmondo Panic issue
S8U6 No 1200 / 1050 / 900 / 750
S8U4, S8U5 750
5.20.9 Obsolete 28 MAR 2008 4 114527-10 47 S8U7,S9,S10 Yes 1200 / 1050 / 900 / 750 1350 / 1200 / 1050 1500 / 1800 /1950 3.5

S8U6 No 1200 / 1050 / 900 / 750
S8U4, S8U5 750
5.20.8 Obsolete 04 JAN 2008 5 114527-09 47 S8U7,S9,S10 Yes 1200 / 1050 / 900 / 750 1350 / 1200 / 1050 1500 / 1800 /1950 3.5

S8U6 No 1200 / 1050 / 900 / 750
S8U4, S8U5 750
5.20.7 Obsolete 12 SEP 2007 1 114527-08 47 S8U7,S9,S10 Yes 1200 / 1050 / 900 / 750 1350 / 1200 / 1050 1500 / 1800 /1950 3.5
Fix Alert <Document 1000062.1> Time jump when SC uptime exceeds 828 days
S8U6 No 1200 / 1050 / 900 / 750
S8U4, S8U5 750
5.20.6 Obsolete 25 JUN 2007 10 114527-07 46 S8U7,S9,S10 Yes 1200 / 1050 / 900 / 750 1350 / 1200 / 1050 1500 / 1800 /1950 3.5

S8U6 No 1200 / 1050 / 900 / 750
S8U4, S8U5 750
5.20.5 Obsolete 27 Feb 2007 1 114527-06 46 S8U7,S9,S10 Yes 1200 / 1050 / 900 / 750 1350 / 1200 / 1050 1500 / 1800 /1950 3.5

S8U6 No 1200 / 1050 / 900 / 750
S8U4, S8U5 750
5.20.4 Obsolete 15 Feb 2007 12 114527-05 46 S8U7,S9,S10 Yes 1200 / 1050 / 900 / 750 1350 / 1200 / 1050 1500 / 1800 / 1950 3.5

S8U6 No 1200 / 1050 / 900 / 750
S8U4, S8U5 750
5.20.3 Obsolete 8 Nov 2006 13 114527-04 46 S8U7,S9,S10 Yes 1200 / 1050 / 900 / 750 1350 / 1200 / 1050 1500 1800 3.5

S8U6 No 1200 / 1050 / 900 / 750
S8U4, S8U5 750
5.20.2 Obsolete 1 Sep 2006 10 114527-03 45 S8U7,S9,S10 Yes 1200 / 1050 / 900 / 750 1350 / 1200 / 1050 1500 1800 3.5

S8U6 No 1200 / 1050 / 900 / 750
S8U4, S8U5 750
5.20.1 Obsolete 20 Jun 2006 9 114527-02 45 S8U7,S9,S10 Yes 1200 / 1050 / 900 / 750 1350 / 1200 / 1050 1500 1800 3.5
Add 1800Mhz Support
S8U6 No 1200 / 1050 / 900 / 750
S8U4, S8U5 750
5.20.0 Obsolete 24 Apr 2006 80 114527-01 45 S8U7,S9,S10 Yes 1200 / 1050 / 900 / 750 1350 / 1200 / 1050 1500 3.5
FMA Enhancements
S8U6 No 1200 / 1050 / 900 / 750
S8U4, S8U5 750



5.20.x Buglist
Sun Fire 5.20.x Firmware BugId Description
Firmware
Version
Description
5.20.17 
<SunBug 6989183">6989183 SC: 'setkeyswitch off' hang after 'Unable to send ECC event message to System Controller' error
Back to Top
5.20.16 
<SunBug 6895919">6895919 Sun Fire 6800 fails to net boot S10U9 AI with FATAL: PROM_PANIC[0x0]: assertion failed
<SunBug 6955039">6955039 COBP Logo change for rebranding to Oracle
Back to Top
5.20.15 
<SunBug 6924389> Move setchs and all remaining showchs options outside of service mode. 
<SunBug 6932351> Unable to update repair activity fields - RepairDetailR & ECO_CurrentR - with 5.20.14.
<SunBug 6942049> LW8 to limit number of simultaneous SSH connections to 2
<SunBug 6944045> Re-brand COBP copyright messages
<SunBug 6944050> Re-brand SCApp copyright messages
Back to Top
5.20.14 
<SunBug 6899962> Scapp needs to recognize ALL LW8 system board containing old D150
<SunBug 6880570> 5.20.14 requires RTOS 49
<SunBug 6864515> Change the default fan speed to High on LW8 systems containg Jaguar/Panther CPU
<SunBug 6847971> Network down when SC uptime exceeds 828 days
Back to Top
5.20.13 
<SunBug 6818412> V1280: boot net install of Solaris 10 U6 (10/08) increases miniroot loadtime to 20 minutes
<SunBug 6815492> Can not unconfigure Primary and Secondary DNS server on lw8 SC
<SunBug 6799628> Post test ID=111.0 indicts slave when master is at fault
Back to Top
5.20.12 
<SunBug 6743184> eeprom security-mode=none panics system
<SunBug 6615537> Asia/Tehran (Iran) time changes in 2009. This fix needed after September 22 2008
<SunBug 6673180> update SCApp timezone with DST/timezone release tzdata2008a.tar.gz
<SunBug 6679219> update SCApp timezone with tzdata2008b.tar.gz DST release
<SunBug 6707386> update SCApp timezone with tzdata2008c.tar.gz DST release
<SunBug 6723209> update SCApp timezone with DST/timezone release tzdata2008d.tar.gz
<SunBug 6736822> update SCApp timezone with DST/timezone release tzdata2008e.tar.gz
<SunBug 6748491> (tz) Support tzdata2008f
<SunBug 6759431> update SCApp timezone with tzdata2008g.tar.gz DST release
<SunBug 6776845> update SCApp timezone with tzdata2008i.tar.gz DST release
Back to Top
5.20.11 
<SunBug 6693002> network-boot-argument with "client-id=" causes "Fast Data Access MMU Miss" on Enterprise servers 
<SunBug 6613280> "Device voltage problem: /N0/PS3 abnormal state for device" on lw8 systems
<SunBug 6737582> AC input loss to power grid causes SC Failover event & an outage to domain on the next grid
<SunBug 6744844> Power cycling failed boards after a power outage causes NullPointerException
<SunBug 6707931> ScApp may be exposed to CERT Advisory CA-95:01

Back to Top
5.20.10 
<SunBug 6618443> Jasper320 raises PERR due to XMITS floating CBE upper bits
<SunBug 6684726> thread stuck in obp resulting in send_mondo panic
Back to Top
5.20.9 
<SunBug 5074808> Domain on E25k panics after hpost level >= 64 with "Safari bus error"
<SunBug 6626545> Timezone changes for Cuba and Syria, tzdata2007i, need to be updated
<SunBug 6638657> Timezone changes from tzdata2007j, need to be updated
<SunBug 6646319> Update SCApp timezones to 2007k (Argentina, Jan Mayen)
Back to Top
5.20.8 
<SunBug 6554527> cpu version 2.4 is not registered with SCApp
<SunBug 6564970> forcing the cpuspeed and ratio via "print PantherAsic.setClockRatio(cpuspeed, ratio)" does not work
<SunBug 6594542> update new timezone changes (tzdata2007g.tar.gz) for Egypt, Indiana, Australia, and Antarctica
<SunBug 6603231> prtdiag shows slot 2/3 at 66MHz, other slots at 100MHz for same PCI-X cards
<SunBug 6611646> update new DST changes (tzdata2007h.tar.gz) for Brazil, Egypt, Iran, Gaza, Venezuela
Back to Top
5.20.7 
<SunBug 6567546> Time jump when SC uptime exceeds 828 days
Back to Top
5.20.6 
<SunBug 5077840> ScApp should decode AFAR during NCPQ_TO event
<SunBug 6486016> unexpected SC failures due to failure to allocate memory from sshd memory partition
<SunBug 6507686> failure of IB caused NullPointerException
<SunBug 6512852> unconfigured domains report "current year is 197?" after a reboot of SC in 2007
<SunBug 6527732> new updates needed for Pulaski County, Indiana, and Turkey changes (tzdata2007c)
<SunBug 6536487> SCApp support needed for new timezone data tzdata2007d and tzdata2007e
<SunBug 6541223> customer problem from LW8_MBOX_SET_LED delay workaround from 4687194
<SunBug 6554415> new timezone changes, tzdata2007f, need to be updated in SCApp firmware
<SunBug 6530133> Panther 1950MHz - POST enhancements for l3-tag
<SunBug 6560118> Panther 1800MHz & 1500MHz - POST enhancements for l3-tag
Back to Top
5.20.5 
<SunBug 6511730> Need to update timezone information for Canada and Western Australia DST + Bahamas
Back to Top
5.20.4 
<SunBug 6356150> Fail to setenv after create nodefault-bytes
<SunBug 6429408> setupplatform should ask for Partition Mode first
<SunBug 6449847> 'Not Applicable' message seen during setupplatform on a E4900 with ScApp
<SunBug 6476648> giving showresetstate command in a powered off system fails RP0
<SunBug 6467598> Exec "ssh-keygen" to generate a DSA hostkey can potentially result in a SC Failover event
<SunBug 6485598> E2900 with 1.95GHz boards allow full population of DIMMS
<SunBug 6487111> unparkCore FAILED warning message seen during setkey on a domain which has a Faulty Ecache
<SunBug 6487355> 1.95GHz downgrading implementation and CPU (in general) handling are incomplete.
<SunBug 6488096> Alignment Error in 5.20.3 but not in 5.20.2
<SunBug 6489629> lshift in 5.20.3 produce wrong result
<SunBug 6489696> Prevent user from setting both tolerate_mem_ce and mpr_support_enable to true using 'setupsc' in lw8
<SunBug 6500532> CR 6405762 fix creates false positives
Back to Top
5.20.3 
<SunBug 6480508> "eeprom" display wanboot security key if it is assigned
<SunBug 6479040> ERROR: Fast Data Access MMU Miss from show-post-results
<SunBug 6479084> 'NOTICE: Security keystore not valid, reinitialized' message seen at the end of every domain POST
<SunBug 4983024> Need to support Wanboot on SF 1280 & 6800
<SunBug 5048077> Failed bulk PS doesn't generate ScApp error / notice event
<SunBug 6300392> Solaris reboot causes AR L2CheckError INCSyncErr CMDVSyncErr PreqSyncErr in adjacent domain
<SunBug 6375533> Main SC can lose access to IDPROM
<SunBug 6383689> Prevent user from setting 'post-tolerate-ce = true' and 'mpr-support-enable = true' w/ 'setupdomain'
<SunBug 6433291> SC should report correct behavior when a System Board Fails and is in Maintenance Mode.
<SunBug 6441484> Black splat on platform agent
<SunBug 6451333> enabling an unavailable PCI slot gives a Fatal error in 5.20.x
<SunBug 6457967> Primary side rectifier over-temp shutdown on PSx on Sun Fire 4900
<SunBug 6469405> Add SCapp support for Panther 1950MHz
Back to Top
5.20.2 
<SunBug 4834243> user ability to determine component health status in a platform
<SunBug 6316045> Support fan tachometer output on LW8 platforms where h/w has fan tachometer capability
<SunBug 6364125> The SC delays the FM connection on resets and failover
<SunBug 6399086> Thread deadlock caused by TreeHelper use of TreePrune
<SunBug 6405762> Fan failures in Sun Fire 3800 - 6800 may cause platform outage
<SunBug 6410597> Blacklist a powered-off component cause java.lang.NullPointerException
<SunBug 6438912> fails to poweron a Panther 1800Mhz board in one particular sequence of swapping PS
<SunBug 6443248> 5.20.0 Preventing 750MHz Boards Powering On When A145 & A145E PSUs are mixed in a SF3800 Chassis
<SunBug 6457922> ID0: SepromSegment.getSepromBytes: cannot load record SepromManufacturing errors seen while booting
<SunBug 6462094> CpuSafariGroup.fillPostStructs: sun.serengeti.FailedHwException: cpu not present or broken
Back to Top
5.20.1 
<SunBug 6395663> E2900 with a single DIMM reporting only CEs CHS disabled all of its CPUs
<SunBug 6399649> HW Eng is requesting the option to margin Vcore to either ?? 25mv or ?? 50mv
<SunBug 6411108> mpr support should be enabled by default on serengeti
<SunBug 6414145> Change Branch Predictor Mode (BPM) in SCAPP/hpost for Panther USIV+
<SunBug 6415272> Fix is needed with AR4 repeaters to prevent L1 queue overflow
<SunBug 6422586> Panther 1800MHz does not require A212 for 6900 and (A213 & FTs) for 4900
<SunBug 6430667> Panther 1800MHz DOES require A213 and Fan Trays for 4900
<SunBug 6424794> PS HW failure causes PS mixtures to exists and preventing SB's to power on
<SunBug 6426489> "voltage 0 is out of valid range: 0.78 - 1.55" message during poweron all
Back to Top
5.20.0 
<SunBug 4859850> hang-policy reset should attempt to get register dump inaddition to reset -x.
<SunBug 5055397> Exec'ing setchs on component being POST'ed could result in hung ScApp shells
<SunBug 5074444> help from enablecomponent and disablecomponent show PCI
<SunBug 6209146> Integrate new SSHield Patch Release (Patch i017 and i018 for SSHield 1.6.1)
<SunBug 6209341> Add a new option to the SCAPP < sepromupdate > command to support Configured_LevelR
<SunBug 6241193> core power write failed.
<SunBug 6248265> java.util.ConcurrentModificationException with showlogs
<SunBug 6252685> Error "JtagController.tapShiftMultiple: sun.serengeti.CommException" for non-Jaguar CPUs.
<SunBug 6273264> Solaris 10/POST not giving correct Panther E$ address (AFAR) on failure
<SunBug 6277490> RFE: AVL-FS2 (Serengeti): Provide Diagnosis of NEW Panther CPU Errors
<SunBug 6277542> l3 ram test only tests 512K of the sram
<SunBug 6278585> Memory Addressing test should support tolerate_mem_ce
<SunBug 6281065> RFE: AVL-FS2 (Serengeti): Support APR
<SunBug 6281990> mem dimm tests indict wrong components
<SunBug 6284667> ShowComp states "disabled" while enable component states its enabled!
<SunBug 6287644> Unable to Poweron a Failed Xmits3.1 I/O assembly
<SunBug 6289142> Request SW support for new A209 power supply for LW8 Panther 1800
<SunBug 6289143> Request SW support for new A212 and A213 power supplies for Serengeti Panther 1800
<SunBug 6289981> "Unknown" is shown for CPU Board Test Status when SCApp showboards shows "Disabled"
<SunBug 6290626> snmp query gets no undertemp status in slot status
<SunBug 6292535> High temp on certain proc Uniboard running dram64 test on MD chassis
<SunBug 6296688> Single-bit CPU DECC error (w/ 'proteus') fails all CPUs
<SunBug 6297086> Single-bit error on DECC line (DIMM signal) w/ post-tolerate-ce=true indicts processo
<SunBug 6298853> runaway lw8 lom console prompt appears after "entering obp" message
<SunBug 6301186> SC doesn't log when domain goes into Active - Panicking state
<SunBug 6306373> ScApp lom shell command 'setalarm 3' does not work as documented
<SunBug 6307803> RFE: AVL-FS2 (Serengeti): SC to supply FMA domains with chassis serial number
<SunBug 6308053> RFE: AVL-FS2 (Serengeti): Support FMA-AVL Datapath Coordination
<SunBug 6308677> Request SW support for new fan for E4900 Panther 1800 and higher
<SunBug 6309268> Panther: Need a cell bit adjacency test for L2$-data and L3$-tags
<SunBug 6309342> Increase clock system frequency tolerance to 3%
<SunBug 6311091> Netra 1290 needs to productize slower Panther CPU speeds.
<SunBug 6311098> Add platform identification for Netra 1290
<SunBug 6311761> Add support for PCI+ boards in LW8
<SunBug 6311763> Add support for Xmits 3.2
<SunBug 6313503> "bootmode reset_nvram" should not change security settings in obp
<SunBug 6314309> ScApp and ntwdt driver states inconsistent after resetsc
<SunBug 6314358> IdProm.java generates hostids; it shouldn't.
<SunBug 6315956> Execution hangs in cpu_stress().
<SunBug 6316080> Branch memory test mishandles traps
<SunBug 6316095> Problems in tolerate_mem_ce implementation
<SunBug 6316530> SERD tunables for CPU events are not consisten between s9u8, s10u1fma, and scapp
<SunBug 6316541> sc cpu de needs to handle l3/l2 cache errors on non-FMA domains so as to not cause proc indictment -v src/
<SunBug 6319704> Panic seen on Serengeti with 5.19.1 firmware after post level of init.
<SunBug 6320701> Wrong Error(UE) caused CHS disabled by 5.19.0 possibly due to Solaris bug 6286861
<SunBug 6321138> hostid is 'ffffffff' in 5.20.0 build 3
<SunBug 6323420> Panther L2$ ECC failures during POST incorrectly FAIL Ecache DIMMs
<SunBug 6325921> Showboard output for Panther board intermittently shows proc at 1510MHz
<SunBug 6329943> mpt driver fails to attach to Jasper320 on LW8 PCI system after max POST
<SunBug 6330120> POST should identify correct SRAM/DIMM when ECC bit fails
<SunBug 6330681> Need to correct lint error introduced by 6319704 putback
<SunBug 6331430> LPOST should support Solaris Memory Page Retirement
<SunBug 6332032> Serengeti SCAPP should support Solaris Memory Page Retirement
<SunBug 6332729> APR : Serial IDs for disabled and CHS tagged DIMMs should not be sent to the domain
<SunBug 6332736> DP : Type 2 message is begin generated for error injection in DCDS <-> DX path
<SunBug 6333725> Panther 1800MHz on V3 and with D185 on V4 Uniboards
<SunBug 6343519> Remove Domain Limitation if AR4 is detected in Repeater Board
<SunBug 6347015> Add support for Panther 2.2
<SunBug 6353053> false VCMON failures due to ramping system load
<SunBug 6354226> POST can attach FRUs which failed interconnect test
<SunBug 6356684> RFE 6309268 regression: L3$ Tags test failure for certain
<SunBug 6360951> need nvci variable 'check-chassis-type' to disable PS/FT checking for Panther 1800 board
<SunBug 6361036> sb poweron fails because non high volume fan trays have been detected.
<SunBug 6361098> Add Panther 1500 MHz productized speed to N1290.
<SunBug 6361149> Can not poweron panther 1800 board unless power cycle the chassis
<SunBug 6361505> When 1800MHz Panthers downclock to 1500MHz there needs to be a message
<SunBug 6363437> Panther 1800MHz on V3 using D185 --- PART 2
<SunBug 6364012> Do not allow SF4810 and SF3800 to poweron Panther 1800 cpus
<SunBug 6369788> Change POSIX timezones 2007 transition dates - U.S. Energy Policy Act of 2005
<SunBug 6372610> poweron SB board failed without reset SC - complete fix for 6361149
<SunBug 6372636> Firmware feature mask settings for Panther do not follow PRM recommendation in some parameters
<SunBug 6378865> Xmit POST initiates Short PCI Reset T_rst<1ms
<SunBug 6379321> IB_SSC fails PCI IO Controller Functional Tests during POST
<SunBug 6380531> AVL:Cache error trains in CPU DE for Panther are incomplete
<SunBug 6388391> Panther 1800 Core Multivoltage Process
<SunBug 6391111> L1 ARs configured incorrectly with AR4 L2 Repeaters.
<SunBug 6398349> Disable AR4 support
<SunBug 6399115> SC reboot message after 01-01-2007, for getting the new 2007 Time Zone (DST) rules
<SunBug 6399657> Add domain restrictions for AR4 boards
<SunBug 6400173> Hotplug delays needed for A212, A213, A209 power supplies.
Back to Top




Other Major Releases
README for Latest Release
Release Date
5.21.X *
5.21.1 <SunPatch:114528-02>
15-Dec-2008
5.19.X
5.19.8 <SunPatch:114526-09>4-Dec-2006
5.18.X
5.18.6 <SunPatch:114525-07>27-Apr-2006
5.17.X
5.17.5 <SunPatch:114524-06>27-Jul-2005
5.16.X
5.16.1  <SunPatch:114523-02>24-Aug-2004
5.15.X
5.15,5 <SunPatch:112884-06>2-Jul-2004
5.14.X
5.14.6 <SunPatch:112883-07>29-Jul-2003
5.13.X
5.13.0015
15-Dec-2003






5.21.1 Includes all the fixes 5.20.11 has, plus support for USBRDT5240. USBRDT5240 Was never released as a product.



To discuss this information further with Oracle experts and industry peers, we encourage you to review, join or start a discussion in an appropriate
My Oracle Support Community - Oracle Sun Technologies Community.



Attachments
This solution has no attachment
  Copyright © 2012 Sun Microsystems, Inc.  All rights reserved.
 Feedback