Asset ID: |
1-79-1021419.1 |
Update Date: | 2012-10-08 |
Keywords: | |
Solution Type
Predictive Self-Healing Sure
Solution
1021419.1
:
SCF-8001-P2 - Fatal error detected within an IOC chip.
Related Items |
- Sun SPARC Enterprise M9000-64 Server
- Sun SPARC Enterprise M9000-32 Server
- Sun SPARC Enterprise M8000 Server
- Sun SPARC Enterprise M3000 Server
- Sun SPARC Enterprise M4000 Server
- Sun SPARC Enterprise M5000 Server
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
|
PreviouslyPublishedAs
SCF-8001-P2
Applies to:
Sun SPARC Enterprise M8000 Server - Version Not Applicable and later
Sun SPARC Enterprise M9000-32 Server - Version Not Applicable and later
Sun SPARC Enterprise M3000 Server - Version Not Applicable and later
Sun SPARC Enterprise M4000 Server - Version Not Applicable and later
Sun SPARC Enterprise M5000 Server - Version Not Applicable and later
All Platforms
Purpose
Provide additional information for message ID: SCF-8001-P2
Details
Predictive Self-Healing Article
Fatal error detected within an IOC chip.
Type
- Fault
- fault.chassis.SPARC-Enterprise.asic.ioc.ch.fe
Severity
- Critical
Description
- A fatal error was detected within an IOC chip. This fatal error affects only a single IO Channel.
Automated Response
- The IO Channel will be deconfigured after the domain is reset.
Impact
- The domain using the IO Channel is reset. The IO Channel will be deconfigured after the domain is reset.
Suggested Action for System Administrator
- Schedule a repair action to replace the affected Field Replaceable Unit (FRU), the identity of which can be determined using fmdump -v -u EVENT_ID. Please consult the detail section of the knowledge article for additional information
Details
- A fatal error was detected within an IOC chip. This fatal error affects only a single IO Channel.
The domain using the IO Channel is reset.
The IO Channel will be deconfigured after the domain is reset.
Availability of I/O devices depends on which IO Channel was deconfigured.
SPARC Enterprise M3000 platform:
IO Channel 0 provides access to all internal I/O and PCI-Express slots 0, 1, 2, and 3.
The platform becomes unbootable.
SPARC Enterprise M4000 platform:
IO Channel 0 provides access to PCI-X slot 0, PCI-Express slots 1 and 2,
and all the internal I/O.
IO Channel 1 provides access to PCI-Express slots 3 and 4.
SPARC Enterprise M5000 platform:
IO Channel 0 provides access to PCI-X slot 0, PCI-Express slots 1 and 2,
and all the internal I/O.
IOU#0: Internal I/O includes the DVD drive, the DAT drive, HDD#0 and HDD#1.
IOU#1: Internal I/O includes HDD#2 and HDD#3.
IO Channel 1 provides access to PCI-Express slots 3 and 4.
SPARC Enterprise M8000/M9000 platforms:
IO Channel 0 on IOC chip 0 provides access to PCI-Express slots 0 and 1 on this IOU.
IO Channel 1 on IOC chip 0 provides access to PCI-Express slots 2 and 3 on this IOU.
IO Channel 0 on IOC chip 1 provides access to PCI-Express slots 4 and 5 on this IOU.
IO Channel 1 on IOC chip 1 provides access to PCI-Express slots 6 and 7 on this IOU.
The recommended service action for this event is to schedule the replacement of the affected FRU.
LEGEND
RED = SUNW-MSG-ID
BLUE = EVENT_ID
GREEN = FRU
Step 1. Collect the fault message (use one of the following methods):
Single-line fault message displayed on the XSCF console:
Mar 20 21:06:00 san-ff2-21-0 fmd: SOURCE: sde, REV: 1.12, CSN: 7860000772
EVENT-ID: bb6e7899-2afe-496a-9e4a-b804a4cb4d3f
Refer to http://www.sun.com/msg/ SCF-8001-P2 for detailed information.
Complete fault message using 'fmdump -m' on the XSCF console:
MSG-ID: SCF-8001-P2, TYPE: Fault, VER: 1, SEVERITY: Critical
EVENT-TIME: Tue Mar 20 21:06:00 UTC 2007
PLATFORM: SPARC-Enterprise, CSN: 7860000772, HOSTNAME: san-ff2-21-0
SOURCE: sde, REV: 1.12
EVENT-ID: bb6e7899-2afe-496a-9e4a-b804a4cb4d3f
DESC: A fatal error was detected within an IOC chip. This fatal error affects only a single
IO Channel.
Refer to http://www.sun.com/msg/SCF-8001-P2 for more information.
AUTO-RESPONSE: The IO Channel will be deconfigured after the domain is reset.
IMPACT: The domain using the IO Channel is reset. The IO Channel will be deconfigured after
the domain is reset.
REC-ACTION: Schedule a repair action to replace the affected Field Replaceable Unit (FRU),
the identity of which can be determined using fmdump -v -u EVENT_ID.
Please consult the detail section of the knowledge article for additional information
Step 2. Collect the output from the 'fmdump -v -u EVENT_ID' command
SPARC Enterprise platform example:
xscf> fmdump -v -u bb6e7899-2afe-496a-9e4a-b804a4cb4d3f
TIME UUID MSG-ID
Mar 20 21:06:00.3088 bb6e7899-2afe-496a-9e4a-b804a4cb4d3f SCF-8001-P2
100% fault.chassis.SPARC-Enterprise.asic.ioc.ch.fe
Problem in: hc:///chassis=0/iou=0/ioc=0/ch=0
Affects: hc:///chassis=0/iou=0/ioc=0/ch=0
FRU: hc://:product-id=SPARC-Enterprise:chassis-id=7860000772:
server-id=san-ff2-21-0:
part=CA20393-B55X 001AA:revision=0101/component=/IOU#0
Step 3. Contact your Authorized Service Provider.
If you require additional information, please refer to Document 1002526.1.
Product
z-Other Server Models 1000-9999
Product_uuid
41751310-63d5-11d7-9179-89d0596b661d
Attachments
This solution has no attachment