Asset ID: |
1-79-1021219.1 |
Update Date: | 2012-10-05 |
Keywords: | |
Solution Type
Predictive Self-Healing Sure
Solution
1021219.1
:
PCI-8000-DH - PCI subsytem problem
Related Items |
- Sun Netra 1280 Server
- Sun Fire V880z Visualization Server
- Sun Fire 3800 Server
- Sun Fire 6800 Server
- Sun Fire E2900 Server
- Sun Fire V440 Server
- Sun Fire V880 Server
- Sun Fire V890 Server
- Sun Fire 280R Server
- Sun Fire 4810 Server
- Sun Fire V1280 Server
- Sun Fire 4800 Server
- Sun Fire V480 Server
- Sun Netra 1290 Server
- Sun Fire E4900 Server
- Sun Fire E6900 Server
- Sun Fire V445 Server
- Sun Netra 440 Server
- Sun Fire V490 Server
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
|
PreviouslyPublishedAs
PCI-8000-DH
Applies to:
Sun Fire 280R Server - Version All Versions and later
Sun Fire 3800 Server - Version All Versions and later
Sun Fire 4800 Server - Version All Versions and later
Sun Fire 4810 Server - Version All Versions and later
Sun Fire 6800 Server - Version All Versions and later
All Platforms
Purpose
Provide additional information for message ID: PCI-8000-DH
Details
Predictive Self-Healing Article
PCI subsytem problem
Type
- Fault
- fault.io.pci.bus-linkerr-unaf
- fault.io.pci.device-interr-unaf
Severity
- Major
Description
- Too many recovered bus faults have been detected, which indicates a problem with the specified bus or with the specified transmitting device. This may degrade into an unrecoverable fault.
Automated Response
- One or more device instances may be disabled
Impact
- Possible loss of services provided by the device instances associated with this fault
Suggested Action for System Administrator
- If a plug-in card is involved check for badly-seated cards or bent pins. Otherwise schedule a repair procedure to replace the affected device. Use fmadm faulty to identify the device and bus or contact Sun for support.
Details
- Too many recovered bus faults have been detected, which indicates a problem with the specified bus or with the specified transmitting device. This may degrade into an unrecoverable fault.
Product
Boards
Product_uuid
e368db18-0fd5-11d8-84cb-080020a9ed93
Attachments
This solution has no attachment