Sun Microsystems, Inc.  Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-79-1021195.1
Update Date:2012-10-05
Keywords:

Solution Type  Predictive Self-Healing Sure

Solution  1021195.1 :   PCI-8000-8S - PCI subsytem problem  


Related Items
  • Sun Netra 1280 Server
  •  
  • Sun Fire V880z Visualization Server
  •  
  • Sun Fire 15K Server
  •  
  • Sun Fire E20K Server
  •  
  • Sun Fire 3800 Server
  •  
  • Sun Fire 6800 Server
  •  
  • Sun Fire E2900 Server
  •  
  • Sun Fire V440 Server
  •  
  • Sun Fire V880 Server
  •  
  • Sun Fire E25K Server
  •  
  • Sun Fire V890 Server
  •  
  • Sun Fire 280R Server
  •  
  • Sun Fire 4810 Server
  •  
  • Sun Fire V1280 Server
  •  
  • Sun Fire 12K Server
  •  
  • Sun Fire 4800 Server
  •  
  • Sun Fire V480 Server
  •  
  • Sun Netra 1290 Server
  •  
  • Sun Fire E4900 Server
  •  
  • Sun Fire E6900 Server
  •  
  • Sun Fire V445 Server
  •  
  • Sun Netra 440 Server
  •  
  • Sun Fire V490 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
  •  

PreviouslyPublishedAs
PCI-8000-8S


Applies to:

Sun Fire 280R Server - Version All Versions and later
Sun Fire 3800 Server - Version All Versions and later
Sun Fire 4800 Server - Version All Versions and later
Sun Fire 4810 Server - Version All Versions and later
Sun Fire 6800 Server - Version All Versions and later
All Platforms

Purpose

Provide additional information for message ID: PCI-8000-8S

Details

Predictive Self-Healing Article
PCI subsytem problem

Type

Fault
  fault.io.pci.bus-linkerr
  fault.io.pci.device-interr

Severity

Critical

Description

An unrecoverable problem has been detected on the specified bus or on the specified transmitting device.

Automated Response

One or more device instances may be disabled

Impact

Possible loss of services provided by the device instances associated with this fault

Suggested Action for System Administrator

If a plug-in card is involved check for badly-seated cards or bent pins. Otherwise schedule a repair procedure to replace the affected device. Use fmadm faulty to identify the device and bus or contact Sun for support.

Details

A problem has been detected on the specified bus or on the specified transmitting device.

Note: If you have encountered this problem on a Sun Blade 1000 system, reported FRUs may be mislabeled. Please reference the following SRDB (Symptom Resolution Data Base) link for further information.

  Document 1011273.1 Sun Blade 1000 FRU Mislabeling