Asset ID: |
1-79-1021195.1 |
Update Date: | 2012-10-05 |
Keywords: | |
Solution Type
Predictive Self-Healing Sure
Solution
1021195.1
:
PCI-8000-8S - PCI subsytem problem
Related Items |
- Sun Netra 1280 Server
- Sun Fire V880z Visualization Server
- Sun Fire 15K Server
- Sun Fire E20K Server
- Sun Fire 3800 Server
- Sun Fire 6800 Server
- Sun Fire E2900 Server
- Sun Fire V440 Server
- Sun Fire V880 Server
- Sun Fire E25K Server
- Sun Fire V890 Server
- Sun Fire 280R Server
- Sun Fire 4810 Server
- Sun Fire V1280 Server
- Sun Fire 12K Server
- Sun Fire 4800 Server
- Sun Fire V480 Server
- Sun Netra 1290 Server
- Sun Fire E4900 Server
- Sun Fire E6900 Server
- Sun Fire V445 Server
- Sun Netra 440 Server
- Sun Fire V490 Server
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
|
PreviouslyPublishedAs
PCI-8000-8S
Applies to:
Sun Fire 280R Server - Version All Versions and later
Sun Fire 3800 Server - Version All Versions and later
Sun Fire 4800 Server - Version All Versions and later
Sun Fire 4810 Server - Version All Versions and later
Sun Fire 6800 Server - Version All Versions and later
All Platforms
Purpose
Provide additional information for message ID: PCI-8000-8S
Details
Predictive Self-Healing Article
PCI subsytem problem
Type
- Fault
- fault.io.pci.bus-linkerr
- fault.io.pci.device-interr
Severity
- Critical
Description
- An unrecoverable problem has been detected on the specified bus or on the specified transmitting device.
Automated Response
- One or more device instances may be disabled
Impact
- Possible loss of services provided by the device instances associated with this fault
Suggested Action for System Administrator
- If a plug-in card is involved check for badly-seated cards or bent pins. Otherwise schedule a repair procedure to replace the affected device. Use fmadm faulty to identify the device and bus or contact Sun for support.
Details
- A problem has been detected on the specified bus or on the specified transmitting device.
Note: If you have encountered this problem on a Sun Blade 1000 system, reported FRUs may be mislabeled. Please reference the following SRDB (Symptom Resolution Data Base) link for further information.
Document 1011273.1 Sun Blade 1000 FRU Mislabeling