Sun Microsystems, Inc.  Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-79-1018446.1
Update Date:2011-06-20
Keywords:

Solution Type  Predictive Self-Healing Sure

Solution  1018446.1 :   VSM - SLS6684I with CC=08 RC=19 or 119  


Related Items
  • Sun StorageTek VSM System
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Virtual Tape>SN-TP: VTL
  •  
  • PLA-Support>Sun Systems>TAPE>Virtual Tape>SN-TP: VSM
  •  

PreviouslyPublishedAs
230031


Applies to:

Sun StorageTek VSM System - Version: 4 to 5C - Release: 4.0 to 5.0
All Platforms

Purpose

This document explains the cause of error SLS6684I with CC=08 RC=19 or 119

VSM - SLS6684I with CC=08 RC=19 or 119

VTV Inventory is full.
The inventory table in the VTSS is full.
For a VSM3, the table can only hold 100,000 VTVs.
For a VSM4 and VSM5, the table can only hold 400,000 VTVs.




Previously Published As
STKKB71930


Attachments
This solution has no attachment
  Copyright © 2012 Sun Microsystems, Inc.  All rights reserved.
 Feedback