Sun Microsystems, Inc.  Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-77-1452085.1
Update Date:2012-04-23
Keywords:

Solution Type  Sun Alert Sure

Solution  1452085.1 :   ALERT - ODA (Oracle Database Appliance) Mandatory OAK Patch 2.1.0.3.1  


Related Items
  • Oracle Database Appliance
  •  
Related Categories
  • PLA-Support>Database Technology>Engineered Systems>Oracle Database Appliance>DB: ODA_EST
  •  


ALERT : ODA shows disks as Missing or in Predictive failure - Urgent Mandatory OAK Patch 2.1.0.3.1

In this Document
Description
Occurrence
Symptoms
Workaround
Patches
History
References


Applies to:

Oracle Database Appliance
Information in this document applies to any platform.
ODA - (Oracle Database Appliance)

Description

 Disks may randomly show as physically missing or in predictive failure after a disk replacement or reboot while using ODA OAK patch level 2.1.0.3.0

Occurrence

There is a high possibility after replacing a disk or if you encounter a crash while on OAK / ODA patchset level 2.1.0.3.0 that you can encounter this problem

You must be on the Oracle Database Appliance (aka ODA)

You must be using 2.1.0.3.0

Please refer to note 888888.1 Oracle Database Appliance - 2.X Supported Versions & Known Issues

 @ this is a cloned note of ALERT - Urgent Mandatory OAK Patch 2.1.0.3.1 (Doc ID 1438089.1)

Symptoms

Disks may show as randomly unavailable, missing or in predictive failure

If you bounce the database or reboot only one of the two ODA servers the problem can still be encountered for the same or different disks

Workaround

Recycling / power down of _both_ of the ODA Servers will relieve the problem.

Patches

 2.1.0.3.1 was created to fix this problem

 2.2.0.x does not have this problem

Obtain OAK Patch 2.1.0.3.1 from the My Oracle Support (MO) website as Patch 13817532.
You will be downloading and installing filename p13817532_21031_Linux-x86-64.zip.
Use the installation instructions that come bundled with the download.

NOTE: OAK Patch 2.1.0.3.1 is not cumulative. This patch must be applied on top of 2.1.0.3.0 only.

History

 Cloned note of ALERT - Urgent Mandatory OAK Patch 2.1.0.3.1 (Doc ID 1438089.1) to meet ALERT criteria - no substantive information added

References

<NOTE:1438089.1> - ALERT - Urgent Mandatory OAK Patch 2.1.0.3.1 for ODA - (Oracle Database Appliance)
<NOTE:888888.1> - Oracle Database Appliance - 2.X Supported Versions & Known Issues

Attachments
This solution has no attachment
  Copyright © 2012 Sun Microsystems, Inc.  All rights reserved.
 Feedback