Solution Type Sun Alert Sure Solution 1405209.1 : ZFS 7310C/7410C Systems With Certain Ethernet Cards may be Unable to Rejoin Cluster
In this Document
Applies to:Sun Microsystems > Storage SoftwareSun Microsystems > Storage - Disk > Unified Storage Sun Software - Generic - Version: Not Applicable and later [Release: N/A and later] Sun Storage 7310 Unified Storage System - Version: Not Applicable and later [Release: N/A and later] Sun Storage 7410 Unified Storage System - Version: Not Applicable and later [Release: N/A and later] Information in this document applies to any platform. ___________________________________ SUNBUG:7132157 Date of Workaround Release: 03-Feb-2012 Date of Resolved Release: 24-Feb-2012 ___________________________________ DescriptionAfter performing an update to the ZFS 7000 Storage Appliance Software 2011.1.1.0 release, Sun ZFS 7310C/7410C appliances with Cluster Controller 100 cards (PN: 371-3024-01) and 4x1Gb Copper Ethernet cards (PN: 375-3481-01) may be unable to rejoin the cluster. Likelihood of OccurrenceThis issue can occur on the following platforms: Sun ZFS 7000 Storage Appliance platforms:
Notes: 1. This issue only occurs on the above systems with the following cards installed, and the system should not be updated to the 2011.1.1.0 release: 371-3024-01 Cluster Controller 100 (Fishworks CLUSTRON 100) card2. To determine the current Storage Appliance Software revision, run the following command: 3. The following command can be run prior to a software update from the Software CLI to determine if the system has the cards that can cause the issue. For example:7000:> maintenance system updates list 7410:> maintenance hardware select chassis-000 select slot show Possible SymptomsOn a system that has this issue, the following warning messages will be displayed on the system console during boot: In addition, the system will not be able to rejoin the cluster, and the following message will be displayed continuously on the system console:SunOS Release 5.11 Version ak/[email protected],1-1.8 64-bit This appliance is part of an appliance cluster. Workaround or ResolutionIf the above symptoms occur after an update to the Storage Appliance Software 2011.1.1.0 release, a rollback to the previous software release should be performed. For example: 7410:> maintenance system updates select [email protected],1-1.37 rollbackYou have requested a rollback of the system software to an earlier version. To This issue is addressed in the following release:
https://wikis.oracle.com/display/FishWorks/Software+Updates Modification History03-Feb-2012: Date of Workaround release24-Feb-2012: Updated for new Software revision, issue is Resolved 27-Feb-2012: Updated to include specific Product Attribution - no change to content Please send technical questions to the following email: [email protected] and copy the Responsible Engineer/Contributor listed Internal Contributor/Submitter: [email protected] Internal Eng Responsible Engineer: [email protected] Internal Services Knowledge Engineer: [email protected] Internal Eng Business Unit Group: ZFS Storage Appliance ReferencesSUNBUG:7132157Attachments This solution has no attachment |
||||||||||||
|