![]() | Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 1495260.1 : SL150 - Operating System Does Not See The Library, But It Does Recognize The Drive
In this Document
Created from <SR 3-6249896621> Applies to:StorageTek SL150 Modular Tape Library - Version All Versions and laterInformation in this document applies to any platform. SymptomsThe OS (Operating System) does not see the library, but it does recgonize the drive. ChangesNew Install CauseMultiple LUN issue or possibly the driver or firmware for the HBA is missing or not correct. SolutionYou need to have multiple LUN support set up on the HBA. Without this, the default is LUN 0 which is for the drive. LUN 1 is for the library. Knowing the interface is SAS and the HBA is most likely our SAS HBA that we OEM from LSI, you need to go to LSI's website to get the latest firmware and drivers for the SAS HBA. Attachments This solution has no attachment |
||||||||||||||||||
|