Solution Type Problem Resolution Sure Solution 1494771.1 : Sun Storage 7000 Unified Storage System: Unable to join Active Directory domain - port blocked by firewall
In this Document
Created from <SR 3-6216132861> Applies to:Sun Storage 7210 Unified Storage System - Version All Versions and laterSun Storage 7410 Unified Storage System - Version All Versions and later Sun Storage 7310 Unified Storage System - Version All Versions and later Sun ZFS Storage 7120 - Version All Versions and later Sun ZFS Storage 7320 - Version All Versions and later 7000 Appliance OS (Fishworks) SymptomsSystem fails to join the Active Directory domain. CauseA snoop of all paths to the Domain Controllers showed the Domain Controller that the system was communicating with was not responding to kpasswd requests. In this case, we found ports required to complete the join were blocked by the firewall. SolutionCheck the network path between the appliance and the domain controller to insure no required ports are blocked by a firewall. The ports required to join an Active Directory domain can be found in MSKB Document 179442.
References<NOTE:1408716.1> - Sun Storage 7000 Unified Storage System: How to Troubleshoot SMB (CIFS) problemsAttachments This solution has no attachment |
||||||||||||||||||
|