Symptoms
Cause
Solution
References


Created from <SR 3-6216132861>

Applies to:

Sun Storage 7210 Unified Storage System - Version All Versions and later
Sun Storage 7410 Unified Storage System - Version All Versions and later
Sun Storage 7310 Unified Storage System - Version All Versions and later
Sun ZFS Storage 7120 - Version All Versions and later
Sun ZFS Storage 7320 - Version All Versions and later
7000 Appliance OS (Fishworks)

Symptoms

System fails to join the Active Directory domain.

Cause

A snoop of all paths to the Domain Controllers showed the Domain Controller that the system was communicating with was not responding to kpasswd requests.
 
The domain controller should provide a response - positive or negative - no response indicates either the message was not transmitted to the Domain Controller or the response is not received by the appliance due to a network path issue.

In this case, we found ports required to complete the join were blocked by the firewall.

Solution

Check the network path between the appliance and the domain controller to insure no required ports are blocked by a firewall.

The ports required to join an Active Directory domain can be found in MSKB Document 179442.

 

References

<NOTE:1408716.1> - Sun Storage 7000 Unified Storage System: How to Troubleshoot SMB (CIFS) problems