Sun Microsystems, Inc.  Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1494017.1
Update Date:2012-09-27
Keywords:

Solution Type  Problem Resolution Sure

Solution  1494017.1 :   GW command showgwports: shows "Line 69, In ? Iport(i, Port) ValueError: Failed To Get Iport Attr"  


Related Items
  • Oracle Exalogic Elastic Cloud X2-2 Hardware
  •  
Related Categories
  • PLA-Support>Database Technology>Engineered Systems>Oracle Exalogic>MW: Exalogic Core
  •  




In this Document
Symptoms
Changes
Cause
Solution


Created from <SR 3-6202874271>

Applies to:

Oracle Exalogic Elastic Cloud X2-2 Hardware - Version All Versions and later
Information in this document applies to any platform.

Symptoms

When running the command showgwports in one of the NM2-GW switches, resulting following error:

 

[root@elorl01gw01-adm ~]#  showgwports

INTERNAL PORTS:
---------------

Device   Port Portname  PeerPort PortGUID           LID    IBState  GWState
---------------------------------------------------------------------------
Bridge-0  1   Bridge-0-1    4    0x002128c376fac001 0x000b Active   Up
Bridge-0  2   Bridge-0-2    3    0x002128c376fac002 0x002f Active   Up
Traceback (most recent call last):
File "/usr/local/bin/showgwports", line 69, in ?
iport = pydcsgw.getiport(i, port)
ValueError: Failed to get iport attrs

 Ideally, the epxected the output should be:

[root@elorl01gw01-adm ~]#  showgwports

INTERNAL PORTS:
---------------

Device   Port Portname  PeerPort PortGUID           LID    IBState  GWState
---------------------------------------------------------------------------
Bridge-0  1   Bridge-0-1    4    0x002128c376fac001 0x000b Active   Up
Bridge-0  2   Bridge-0-2    3    0x002128c376fac002 0x002f Active   Up
Bridge-1  1   Bridge-1-1    2    0x002128c376fac041 0x0035 Active   Up
Bridge-1  2   Bridge-1-2    1    0x002128c376fac042 0x0055 Active   Up

CONNECTOR 0A-ETH:
-----------------

Port      Bridge      Adminstate Link  State       Linkmode       Speed
------------------------------------------------------------------------
0A-ETH-1  Bridge-0-2  Enabled    Up    Up          XFI            10Gb/s
0A-ETH-2  Bridge-0-2  Enabled    Up    Up          XFI            10Gb/s
0A-ETH-3  Bridge-0-1  Enabled    Down  Reset       XFI            10Gb/s
0A-ETH-4  Bridge-0-1  Enabled    Down  Reset       XFI            10Gb/s

CONNECTOR 1A-ETH:
-----------------

Port      Bridge      Adminstate Link  State       Linkmode       Speed
------------------------------------------------------------------------
1A-ETH-1  Bridge-1-2  Enabled    Down  Reset       XFI            10Gb/s
1A-ETH-2  Bridge-1-2  Enabled    Down  Reset       XFI            10Gb/s
1A-ETH-3  Bridge-1-1  Enabled    Down  Reset       XFI            10Gb/s
1A-ETH-4  Bridge-1-1  Enabled    Down  Reset       XFI            10Gb/s

 

Changes

 The issue was faced on InfiniBand Gateway Switch (NM2-GW), firmware version 2.0.4-1

[root@elorl01gw01-adm ~]# version
SUN DCS gw version: 2.0.4-1
Build time: Oct 17 2011 10:04:07
FPGA version: 0x34
SP board info:
Manufacturing Date: 2010.12.31
Serial Number: "XXXXXXXXX"
Hardware Revision: 0x0006
Firmware Revision: 0x0000
BIOS version: SUN0R100
BIOS date: 06/22/2010

 

Cause

This is a known issue and resolved through the Sun CR 7167619
 

Solution

The fix went into the version 2.1.2. Till the fix is available, a feasible solution is to restart the switch in question.
 