Sun Microsystems, Inc.  Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1493870.1
Update Date:2012-10-05
Keywords:

Solution Type  Problem Resolution Sure

Solution  1493870.1 :   ibdiagnet.log shows error IPoIB Subnets Check & need to reset error counter  


Related Items
  • Exadata Database Machine X2-2 Half Rack
  •  
Related Categories
  • PLA-Support>Sun Systems>x64>Engineered Systems HW>SN-x64: EXADATA
  •  




In this Document
Symptoms
Cause
Solution


Created from <SR 3-6036126041>

Applies to:

Exadata Database Machine X2-2 Half Rack - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Symptoms

The following command may show the results as below :-

#/usr/bin/ibdiagnet -pm


-I- Stages Status Report:
  STAGE Errors Warnings
  Bad GUIDs/LIDs Check 0 0
  Link State Active Check 0 6
  Performance Counters Report 0 0
  Partitions Check 0 0
  IPoIB Subnets Check 0 2

 Please see /tmp/ibdiagnet.log for complete log

Cause

These errors are harmless
 

Solution

To reset the values back to zero, please execute the following command :-

#/usr/sbin/ibclearerrors

  

And then execute the commands to check if values are reset to zero :- 

#/usr/bin/ibdiagnet -pm

-I- Stages Status Report:
   STAGE                                    Errors Warnings
   Bad GUIDs/LIDs Check                     0      0    
   Link State Active Check                  0      0    
   Performance Counters Report              0      0    
   Partitions Check                         0      0    
   IPoIB Subnets Check                      0      0 

 

Please see /tmp/ibdiagnet.log for complete log
 


Attachments
This solution has no attachment
  Copyright © 2012 Sun Microsystems, Inc.  All rights reserved.