Sun Microsystems, Inc.  Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1491956.1
Update Date:2012-10-01
Keywords:

Solution Type  Problem Resolution Sure

Solution  1491956.1 :   Sun Storage 7000 Unified Storage System: "The JBOD '' is configured incorrectly" is reported  


Related Items
  • Sun Storage 7310 Unified Storage System
  •  
  • Sun Storage 7410 Unified Storage System
  •  
  • Sun ZFS Storage 7120
  •  
  • Sun Storage 7110 Unified Storage System
  •  
  • Sun ZFS Storage 7420
  •  
  • Sun ZFS Storage 7320
  •  
  • Sun Storage 7210 Unified Storage System
  •  
Related Categories
  • PLA-Support>Sun Systems>DISK>NAS>SN-DK: 7xxx NAS
  •  




In this Document
Symptoms
Cause
Solution


Created from <SR 3-6059798661>

Applies to:

Sun ZFS Storage 7420 - Version Not Applicable to Not Applicable [Release N/A]
Sun ZFS Storage 7320 - Version Not Applicable to Not Applicable [Release N/A]
Sun ZFS Storage 7120 - Version Not Applicable to Not Applicable [Release N/A]
Sun Storage 7410 Unified Storage System - Version Not Applicable to Not Applicable [Release N/A]
Sun Storage 7310 Unified Storage System - Version Not Applicable to Not Applicable [Release N/A]
7000 Appliance OS (Fishworks)

Symptoms

To discuss this information further with Oracle experts and industry peers, we encourage you to review, join or start a discussion in the My Oracle Support Community - 7000 Series ZFS Appliances

 

An error is seen in the "maintenance - problems" screen of the BUI with a description like:

Properties:                                                                                                                        
                         uuid = fb8e6c4f-c75f-e2bc-946d-ca078423dc1e                                                              
                         code = AK-8000-H7                                                                                        
                    diagnosed = 2012-8-8 12:54:13                                                                                  
                  phoned_home = never                                                                                              
                     severity = Major                                                                                              
                         type = Defect                                                                                            
                          url = http://sun.com/msg/AK-8000-H7                                                                      
                  description = The JBOD '<Serial Number>' is configured incorrectly.                                                                                      
                       impact = The disks contained within the enclosure cannot be used as part of a storage pool.                                                          
                     response = None.                                                                                              
                       action = Correct the disk configuration to conform to a valid configuration.                                                                              
                                                                                                                                   
Components:                                                                                                                        
                                                                                                                                   
component-000  100%  <Serial Number>: hc://:product-id=SUN-Storage-J4410:chassis-id=<Serial Number>:serial=<Serial Number>:part=7041262:revision=3527/ses-enclosure=4 (degraded)                              
                    Manufacturer: Sun Microsystems, Inc.                                                                          
                    Part number: 7041262                                                                                          
                    Model: Sun Disk Shelf (SAS-2)                                                                                  
                    Revision: 3527

Cause

This error means that the JBOD identified in the alert is somehow misconfigured - most likely due to a faulty piece of hardware contained within it.

A common cause of this error is a disk that has failed in such a way that it is reported as "absent" rather than "faulted" in the configuration.

The problem may also be a faulty SIM or a SIM with mismatched firmware to the other SIM in the JBOD.

Check this by reviewing the hardware configuration in the BUI:

Maintenance > hardware

Select the correct JBOD identified by the <Serial Number> in the alert and click on "Show Details"

Alternatively in CLI type:

S7000:> maintenance hardware list

S7000: maintenance hardware> select chassis-00X show                     

where chassis-00X is the chassis with the name identified in the alert.

Solution

If a disk is marked as absent, then check it is seated correctly.  Try reseating it and see if it comes back online.

If a SIM is faulted or has mismatched firmware also try reseating this.  Before reseating a SIM first check that you have a valid second path to the disks in the JBOD.

This can be seen from the BUI:

maintenance > hardware

Check the number of PATHS listed against the appropriate disk shelf.

or from CLI:

S7000: maintenance hardware select chassis-00X show

where chassis-00X is the name of the chassis identified in the alert.

The number of paths is listed under Properties:

 

If reseating does not fix the issue, then raise a Service Request with Oracle Support to get the issue investigated and/or the problem part replaced.


Attachments
This solution has no attachment
  Copyright © 2012 Sun Microsystems, Inc.  All rights reserved.
 Feedback