Solution  1490986.1 :   (Field) T5240/All fans reporting as failed  


Related Items
  • Sun SPARC Enterprise T5240 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>SPARC>CMT>SN-SPARC: T5xx0
  •  




In this Document
Symptoms
Cause
Solution


Created from <SR 3-6115460692>

Applies to:

Sun SPARC Enterprise T5240 Server - Version Not Applicable to Not Applicable [Release N/A]
Information in this document applies to any platform.

Symptoms

Customer reporting that all fans are showing as failed via prtdiag output

Cause

##### Tx000/showenvironment   #####
/SYS/LOCATE                    /SYS/SERVICE                   /SYS/ACT
OFF                            ON                             ON

/SYS/PS_FAULT                  /SYS/TEMP_FAULT                /SYS/FAN_FAULT
OFF                            OFF                            ON

Sensor                         Status       Speed     Warn      Low
/SYS/FANBD0/FM0/F0/TACH        FAILED           0     4000     2400
/SYS/FANBD0/FM0/F1/TACH        FAILED           0     4000     2400
/SYS/FANBD0/FM1/F0/TACH        FAILED           0     4000     2400
/SYS/FANBD0/FM1/F1/TACH        FAILED           0     4000     2400
/SYS/FANBD0/FM2/F0/TACH        FAILED           0     4000     2400
/SYS/FANBD0/FM2/F1/TACH        FAILED           0     4000     2400
/SYS/FANBD1/FM0/F0/TACH        FAILED           0     4000     2400
/SYS/FANBD1/FM0/F1/TACH        FAILED           0     4000     2400
/SYS/FANBD1/FM1/F0/TACH        FAILED           0     4000     2400
/SYS/FANBD1/FM1/F1/TACH        FAILED           0     4000     2400

        /SYS/FANBD0  Dialog             5017695-03  E03NTD               109 (36 degrees C)  0x10 (PROXIED FAULT)
        /SYS/FANBD1  FOXCONN            5017695-04  E09NE8               94 (21 degrees C)   0x10 (PROXIED FAULT)


Component     : /SYS/FANBD0
Time Stamp    : Thu, Dec 21 2000 12:17:06 GMT
New_Status    : 0x10 (PROXIED FAULT)
Old_Status    : 0x10 (PROXIED FAULT)
Initiator     : SCAPP
Component     : 50
Message       : TACH at /SYS/FANBD0/FM2/F0 has exceeded low non-recoverable threshold.

Component     : /SYS/FANBD1
Time Stamp    : Thu, Dec 21 2000 12:18:14 GMT
New_Status    : 0x10 (PROXIED FAULT)
Old_Status    : 0x10 (PROXIED FAULT)
Initiator     : SCAPP
Component     : 53
Message       : TACH at /SYS/FANBD1/FM1/F0 has exceeded low non-recoverable threshold.


##### Tx000/showfaults_-v   #####
Last POST Run: Mon Oct 23 13:57:23 2000

Post Status: Passed all devices
 ID Time                           FRU               Class             Fault
  1 Dec 21 12:16:01                /SYS/FANBD0/FM0                     SP detected fault: TACH at /SYS/FANBD0/FM0/F0 has exceeded low non-recoverable threshold.
  2 Dec 21 12:15:57                /SYS/FANBD0/FM0                     SP detected fault: TACH at /SYS/FANBD0/FM0/F1 has exceeded low non-recoverable threshold.
  3 Dec 21 12:16:34                /SYS/FANBD0/FM1                     SP detected fault: TACH at /SYS/FANBD0/FM1/F0 has exceeded low non-recoverable threshold.
  4 Dec 21 12:16:30                /SYS/FANBD0/FM1                     SP detected fault: TACH at /SYS/FANBD0/FM1/F1 has exceeded low non-recoverable threshold.
  5 Dec 21 12:17:06                /SYS/FANBD0/FM2                     SP detected fault: TACH at /SYS/FANBD0/FM2/F0 has exceeded low non-recoverable threshold.
  6 Dec 21 12:17:02                /SYS/FANBD0/FM2                     SP detected fault: TACH at /SYS/FANBD0/FM2/F1 has exceeded low non-recoverable threshold.
  7 Dec 21 12:17:41                /SYS/FANBD1/FM0                     SP detected fault: TACH at /SYS/FANBD1/FM0/F0 has exceeded low non-recoverable threshold.
  8 Dec 21 12:17:38                /SYS/FANBD1/FM0                     SP detected fault: TACH at /SYS/FANBD1/FM0/F1 has exceeded low non-recoverable threshold.
  9 Dec 21 12:18:14                /SYS/FANBD1/FM1                     SP detected fault: TACH at /SYS/FANBD1/FM1/F0 has exceeded low non-recoverable threshold.
 10 Dec 21 12:18:10                /SYS/FANBD1/FM1                     SP detected fault: TACH at /SYS/FANBD1/FM1/F1 has exceeded low non-recoverable threshold.

Errors due to a known issue regarding corrosion residue

 
Both fan boards are showing as failed, likely due to corrosion residue on the fan board connector and/or the fretting.

HF1: SP Powers Off HOST. On subsequent HOST Power Up the SP Powers Off HOST Quickly. Snapshot SP Event and/or FMA logs show Fan Brd and/or Multiple FAN Module Failures. Closed 6925325 Fan: A unique characteristic of this Issue is that PATA/SATA Connector Board Connector (Pins) and/or Fan Brd Edge Connector show corrosion residue, and/or smokey Film (This is NOT a Thermal Event) and/or Fan Board Edge Connector Finger Fretting (distortion, lifting). The connector manufacturer has resolved this problem so new systems will not be affected.
FIX: Replace the Connector Board and Both Fan Boards
 

Solution

 

Create on-site task for fan board and connector board replacements
 