Solution Type Problem Resolution Sure Solution 1490986.1 : (Field) T5240/All fans reporting as failed
In this Document
Created from <SR 3-6115460692> Applies to:Sun SPARC Enterprise T5240 Server - Version Not Applicable to Not Applicable [Release N/A]Information in this document applies to any platform. SymptomsCustomer reporting that all fans are showing as failed via prtdiag output Cause##### Tx000/showenvironment #####
/SYS/LOCATE /SYS/SERVICE /SYS/ACT OFF ON ON /SYS/PS_FAULT /SYS/TEMP_FAULT /SYS/FAN_FAULT OFF OFF ON Sensor Status Speed Warn Low /SYS/FANBD0/FM0/F0/TACH FAILED 0 4000 2400 /SYS/FANBD0/FM0/F1/TACH FAILED 0 4000 2400 /SYS/FANBD0/FM1/F0/TACH FAILED 0 4000 2400 /SYS/FANBD0/FM1/F1/TACH FAILED 0 4000 2400 /SYS/FANBD0/FM2/F0/TACH FAILED 0 4000 2400 /SYS/FANBD0/FM2/F1/TACH FAILED 0 4000 2400 /SYS/FANBD1/FM0/F0/TACH FAILED 0 4000 2400 /SYS/FANBD1/FM0/F1/TACH FAILED 0 4000 2400 /SYS/FANBD1/FM1/F0/TACH FAILED 0 4000 2400 /SYS/FANBD1/FM1/F1/TACH FAILED 0 4000 2400 /SYS/FANBD0 Dialog 5017695-03 E03NTD 109 (36 degrees C) 0x10 (PROXIED FAULT) /SYS/FANBD1 FOXCONN 5017695-04 E09NE8 94 (21 degrees C) 0x10 (PROXIED FAULT) Component : /SYS/FANBD0 Time Stamp : Thu, Dec 21 2000 12:17:06 GMT New_Status : 0x10 (PROXIED FAULT) Old_Status : 0x10 (PROXIED FAULT) Initiator : SCAPP Component : 50 Message : TACH at /SYS/FANBD0/FM2/F0 has exceeded low non-recoverable threshold. Component : /SYS/FANBD1 Time Stamp : Thu, Dec 21 2000 12:18:14 GMT New_Status : 0x10 (PROXIED FAULT) Old_Status : 0x10 (PROXIED FAULT) Initiator : SCAPP Component : 53 Message : TACH at /SYS/FANBD1/FM1/F0 has exceeded low non-recoverable threshold. ##### Tx000/showfaults_-v ##### Last POST Run: Mon Oct 23 13:57:23 2000 Post Status: Passed all devices ID Time FRU Class Fault 1 Dec 21 12:16:01 /SYS/FANBD0/FM0 SP detected fault: TACH at /SYS/FANBD0/FM0/F0 has exceeded low non-recoverable threshold. 2 Dec 21 12:15:57 /SYS/FANBD0/FM0 SP detected fault: TACH at /SYS/FANBD0/FM0/F1 has exceeded low non-recoverable threshold. 3 Dec 21 12:16:34 /SYS/FANBD0/FM1 SP detected fault: TACH at /SYS/FANBD0/FM1/F0 has exceeded low non-recoverable threshold. 4 Dec 21 12:16:30 /SYS/FANBD0/FM1 SP detected fault: TACH at /SYS/FANBD0/FM1/F1 has exceeded low non-recoverable threshold. 5 Dec 21 12:17:06 /SYS/FANBD0/FM2 SP detected fault: TACH at /SYS/FANBD0/FM2/F0 has exceeded low non-recoverable threshold. 6 Dec 21 12:17:02 /SYS/FANBD0/FM2 SP detected fault: TACH at /SYS/FANBD0/FM2/F1 has exceeded low non-recoverable threshold. 7 Dec 21 12:17:41 /SYS/FANBD1/FM0 SP detected fault: TACH at /SYS/FANBD1/FM0/F0 has exceeded low non-recoverable threshold. 8 Dec 21 12:17:38 /SYS/FANBD1/FM0 SP detected fault: TACH at /SYS/FANBD1/FM0/F1 has exceeded low non-recoverable threshold. 9 Dec 21 12:18:14 /SYS/FANBD1/FM1 SP detected fault: TACH at /SYS/FANBD1/FM1/F0 has exceeded low non-recoverable threshold. 10 Dec 21 12:18:10 /SYS/FANBD1/FM1 SP detected fault: TACH at /SYS/FANBD1/FM1/F1 has exceeded low non-recoverable threshold. Errors due to a known issue regarding corrosion residue Solution
Create on-site task for fan board and connector board replacements Attachments This solution has no attachment |
||||||||||||||||
|