Asset ID: |
1-72-1487840.1 |
Update Date: | 2012-09-05 |
Keywords: | |
Solution Type
Problem Resolution Sure
Solution
1487840.1
:
SL48 - LIB/ERR 80 F4 91 17 2B 0F 00 00 00 00 00 00 FF 02 01 FF, drive load timeout
Related Items |
- Sun StorageTek SL48 Tape Library
|
Related Categories |
- PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: OEM Drive and Library
|
In this Document
Created from <SR 3-6144184131>
Applies to:
Sun StorageTek SL48 Tape Library - Version Not Applicable to Not Applicable [Release N/A]
Information in this document applies to any platform.
Symptoms
LIB/ERR<80 F4 91 17 2B 0F 00 00 00 00 00 00 FF 02 01 FF
04 02 02 4B 4B 47 31 31 37 4C 34 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 > HE: drive load timeout
Cause
Possible issues:
1. Media damaged.
2. Drive damaged.
Physically damaged media or drive can cause problem in loading.
Solution
1. Try loading a couple of known good tapes in the drive.
2. If media works fine in the other drive and not in the drive in question then replace the drive.
3. If media does not work in any drive then replace the media.
Attachments
This solution has no attachment