CheckHWnFWProfile Shows "All Drives Are Not Identical" - Firmware Difference In Physical Disk
Related Items |
- Exadata Database Machine X2-2 Hardware
|
Related Categories |
- PLA-Support>Sun Systems>x64>Engineered Systems HW>SN-x64: EXADATA
|
Created from <SR 3-6109339101>
Applies to:
Exadata Database Machine X2-2 Hardware - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.
Symptoms
Newly added disk shows higher firmware as per an example output below:
[root@excel ~]# cellcli -e "list physicaldisk where disktype=harddisk attributes slotnumber,makemodel,physicalfirmware"
0 "SEAGATE ST360057SSUN600G" 0805
1 "SEAGATE ST360057SSUN600G" 0805
2 "SEAGATE ST360057SSUN600G" 0805
3 "SEAGATE ST360057SSUN600G" 0805
4 "SEAGATE ST360057SSUN600G" 0805
5 "SEAGATE ST360057SSUN600G" 0805
6 "SEAGATE ST360057SSUN600G" 0805
7 "SEAGATE ST360057SSUN600G" 0805
8 "SEAGATE ST360057SSUN600G" 0805
9 "SEAGATE ST360057SSUN600G" 0805
10 "SEAGATE ST360057SSUN600G" 0A25 <================== Newer firmware
11 "SEAGATE ST360057SSUN600G" 0805
Changes
Replaced a bad disk with a new disk.
Cause
The new disk comes with latest firmware.
Solution
<Bug: 13796177> DRIVE FIRMWARE CHECKHWNFWPROFILE -C STRICT ALL DRIVES ARE NOT IDENTICAL
Extract:
0A25 is a higher firmware versions than 0805.
So, we may leave the disk, with the current firmware version. As long as we are equal or higher than the minimum firmware version, we are fine.
CheckHWnFWProfile basically compares the disk firmware versions with the hardcoded values, this might be the reason why we are seeing the errors, which can be ignored at this time.
When you upgrade your exadata, all disks will get the latest firmware.