Symptoms
Cause
Solution


Created from <SR 3-6086082216>

Applies to:

Sun StorageTek SL8500 Modular Library System - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Symptoms

Summary:1318: "Remote library will not accept command transfer", sourceAddress=1,2,-10,1,3 destinationAddre

1318: "Remote library will not accept command transfer", sourceAddress=1,2,-10,1
Full Summary:1318: "Remote library will not accept command transfer", sourceAddress=1,2,-10,1,3 destinationAddress=2,2,-2,1,3 volser=894324~R;
Full Description:1318: "Remote library will not accept command transfer", sourceAddress=1,2,-10,1,3 destinationAddress=2,2,-2,1,3 volumeLabel=894324~R;
SdpIncidentId: 17900466
Events -------------------------1318 (Critical): "Remote library will not accept command transfer", sourceAddress=1,2,-10,1,3 destinationAddress=2,2,-2,1,3 volumeLabel=894324~R

Result code 1318, RC1318

Cause

Source library in the Complex is not ready for accepting command from the destination library.
 
Time : 2012-08-16T04:36:13.929
  Device Address : 1.0.0.0.0
  User : root
  Requester : hli0
  Activity : move
  Request Id : 18292190
  Level : error
  Result Code : 1318
  Text : "Remote library will not accept command transfer"
  Parameters : sourceAddress=1,2,-10,1,3 destinationAddress=2,2,-2,1,3 volumeLabel=894324~R
 

Solution

Error Indicates that the source library was not ready for accepting the commands from the destination library for tape movement.
There may be an issue with the PTPs(Pass Through Port) involved.
Source library may be busy and may not be ready to accept the command from destination library.
Access the library console and check Tools>System Details>PTP folder for all the libraries in question(Between the Source and Destination in the error)
If any PTP is down, troubleshoot the PTP.
If no device listed as disabled, then monitor the library and see if the error recurs.
This might be just a one time occurrence which does not necessarily indicate an issue.
 