![]() | Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Problem Resolution Sure Solution 1484120.1 : Incorrect RIO Voltage Readings reported on T4-4 and T4-2
In this Document
Applies to:SPARC T4-4 - Version Not Applicable to Not Applicable [Release N/A]SPARC T4-2 - Version Not Applicable to Not Applicable [Release N/A] Information in this document applies to any platform. Symptoms
Messages similar to this are reported: Sensor | minor: Voltage : /SYS/RIO/VDD_+1V8 : Lower Non-critical going high : reading 1.82 >= threshold 1.71 Volts Cause Getting bad readings on A239 power supplies on T4-4 and T4-2 platforms. Data is reading 0 for some amount of time so need to apply post filtering on all devices on that leg of i2c bus to deal with the bad data. On T4-4, RIO/TGB are on the same i2c bus segment as PSU. SolutionUpgrade to f/w 8.2.0.f or later. Attachments This solution has no attachment |
||||||||||||||||
|