Sun Microsystems, Inc.  Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1483597.1
Update Date:2012-08-17
Keywords:

Solution Type  Problem Resolution Sure

Solution  1483597.1 :   Unable to start subnet manager on an Infiniband Spine switch  


Related Items
  • Exadata Database Machine X2-2 Full Rack
  •  
Related Categories
  • PLA-Support>Database Technology>Engineered Systems>Oracle Exadata>DB: Exadata_EST
  •  
  • .Old GCS Categories>ST>Server>Engineered Systems>Exadata>Hardware
  •  




Created from <SR 3-6055876216>

Applies to:

Exadata Database Machine X2-2 Full Rack - Version Not Applicable and later
Information in this document applies to any platform.

Symptoms

 

  • Trying to enable the subnet manager on the spine IB switch , it failed.
  • sminfo executed on other switch, reports status as SMINFO_STANDBY

 

Changes

 none

Cause

Problem is due to the wrong status of the master subnet manager

On the leaf switch, sminfo is returning

sminfo: sm lid 3 sm guid 0x21286ccbeea0a0, activity count 37512519 priority 14 state 2 SMINFO_STANDBY
 
This is caused by an incorrect content of file /conf/configvalid, having 0 instead of 1.
 

Solution

To fix the problem, log into the IB switch with the problem.

#disablesm
#echo 1 > /conf/configvalid
#enablesm
 


Attachments
This solution has no attachment
  Copyright © 2012 Sun Microsystems, Inc.  All rights reserved.